background image

install cotter pin into cross pin.

Install downrod into yoke.

Raise fan with downrod assembled to the ceil-

ing bracket and hang fan assembly.  Be sure to

rotate the downrod ball so that the notch in the

bracket engages the slot in the ball.

11

15

9

For Canadian installation in both flush and

downrod mode the safety cable must be

installed into the house structure beams using

the 3” lag screws provided.  Make sure that

when the safety cable is fully extended the

leadwires are longer than the cable and no

stress is placed on the leadwires.

16

Canadian mounting only

Safety Cable

Lag Screw

Make wire connections to power source using

wire nuts provided.  Make sure that no filiments

are outside of the wirenut. After making the

wire connections, the wires should be spread

apart with the grounded conductor and the

equipment-grounding conductor on one side of

the outlet box and ungrounded conductor on

the other side of the outlet box.

18

Loosen 2 screws and remove pin with keeper

for downrod, yoke cover and canopy to fit in

yoke of fan.

8

Thread black, white wire, and safety cable

through downrod

7

Make wire connections as per above diagram.

Connect the white wire from the fan to the

White or Neutral wire from the power source.

Connect the black wire from the fan to the

Black or hot wire from the power source.

Connect all Green / Yellow wires from the fan,

Downrod and mounting bracket to the Ground

wire from the house.  

17

Set dip switches on the Remote Transmitter and Remote

Receiver to the same settings.  This must be done so the

units will communcate properly.  If you have other fans you

can set to control from one transmitter by setting both

receivers the same as the transmitter.  If you have more

than one fan with remote.  You can set the dip switches to

different positiosns to have seperate control.

Remote Transmitter Dip swtiches

Remote Receiver Dip switches

14

Align hole in downrod with hole in yoke and

install cross pin.

10

Tighten 2 downrod set screws and lock nuts.

12

Remove switch housing cap by removing 1

screw without key slots and loosening the other

2 screws and twist to remove.

13

Содержание 5MYR56 Series

Страница 1: ...Quality Ceiling fans Owner s Manual Ceiling Fan Installation Instructions For 5MYR56 Series Fans READ AND SAVE THESE INSTRUCTIONS Total fan weight ...

Страница 2: ... a tub or shower it must be marked as appropriate for the application NEVER place a switch where it can be reached from a tub or shower The combustion airflow needed for safe operation of fuel burning equipment may be affected by this unit s operation Follow the heating equip ment manufacturer s guideline safety standards such as those published by the National Fire Protection Association NFPA and...

Страница 3: ...s and remove pin with keeper for downrod yoke cover and canopy to fit in yoke of fan 8 Thread black white wire and safety cable through downrod 7 Make wire connections as per above diagram Connect the white wire from the fan to the White or Neutral wire from the power source Connect the black wire from the fan to the Black or hot wire from the power source Connect all Green Yellow wires from the f...

Страница 4: ...tabs and remove them if they are present The screws washers and motor pads are pre installed to the blade holders Attach blade assembly to motor and tighten screws securely 21 Lift Canopy to ceiling aligning the key hole slots with the screws on the bottom of the Mounting bracket Rotate the canopy Counter Clockwise to lock in place Tighten the screws to secure the Canopy See inset for Keyhole shap...

Страница 5: ... the following procedure To adjust a blade tip down insert a washer not supplied between the blade and blade holder at the screw closest to the motor To adjust a blade tip up insert washer not supplied between the blade and blade holder at the two screws farthest from the motor Reverse the position of the washer if blades mount from top of blade 6 If blade wobble is still noticeable interchanging ...

Отзывы: