background image

Installation work and electrical wiring must be done by qualified person(s) in accordance with  applicable codes and standards (ANSI/NFPA 70-

1999), including fire-rated construction.

Use this unit only in the manner intended by the manufacurer.  If you have  any questions contact the manufacturer.

After making the wire connections, the wires should be spread apart with the grounded conductor and the equipment-grounding conductor on

one side of the outlet box and ungrounded conductor on the other side of the outlet box.

Before you begin installing the fan, Switch power off at Service panel and lock service disconnecting means to prevent power from being

switched on accidentally.  When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such  as a tag,

to the service panel.

Be cautious! read all instructions and safety information before installing your new fan. Review the accompanying assembly diagrams.

When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.

Make sure the installation site you choose allows the fan blades to rotate without any obstructions. Allow a minimum clearance of 7 feet from

the floor to the trailing edge of the blade.

WARNING – Risk of fire, electric shock, or personal injury, The fan in this box may be either directly supported from a structural framing mem-

ber of a building and/or may be mounted to an outlet box marked acceptable for fan support of 31.8 kg. (70 lbs.) or less. Most outlet boxes

commonly used for the support of luminaires may not be acceptable for fan support and may need to be replaced. Consult a qualified electrician

if in doubt.

Do not bend blade holders during installation to motor, balancing or during cleaning.  Do not insert foreign object between rotating blades.

Attach the mounting bracket using only the hardware supplied with the outlet box.

To reduce the risk of fire or electric shock, do not use this fan with any solid state fan speed control device, or variable speed control.

If this unit is to be installed over a tub or shower, it must be marked as appropriate for the application.

NEVER place a switch where it can be reached from a tub or shower.

The combustion airflow needed for safe operation of fuel-burning equipment may be affected by this unit’s operation. Follow the heating equip-

ment manufacturer’s guideline safety standards such as those published by the National Fire Protection Association (NFPA), and the American

Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE) and the local code authorities.

Before servicing or cleaning unit, Switch power off at Service panel and lock service disconnecting means to prevent power from being switched

on accidentally.  When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such  as a tag, to the

service panel.

1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

11.

12.

13.

14.

15.

Installation

WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS,

OBSERVE THE FOLLOWING: READ AND SAVE THESE INSTRUCTIONS

S

AFETY

T

IPS

TTO

OO

OLLSS R

REEQ

QU

UIIR

REED

D

PPhhiilllliippss SSccrreew

wddrriivveerr      W

Wiirree CCuutttteerrss       PPlliieerrss

SStteepp LLaaddddeerr

Before you begin installing the fan, Switch

power off at Service panel and lock service dis-

connecting means to prevent power from being

switched on accidentally.  When the service dis-

connecting means cannot be locked, securely

fasten a prominent warning device, such  as a

tag, to the service panel.

Warning-Risk of fire, electric shock, or person-

al injury. The fan in this box may be either

directly supported from a structural framing

member of a building and/or may be mounted

to an outlet box marked acceptable for fan sup-

port of of 31.8 kg (70 lbs) or less. Most outlet

boxes commonly used for the support of lummi-

naires may not be acceptable for fan support

and may need to be replaced. Consult a quali-

fied electrician if in doubt. 

2

1

OUTLET BOX METHOD

Remove Safety bar from mounting bracket by

loosing screws, sliding bar to side, and lifting it

off the 2 screws.

3

Remove the 4 screws attaching the Mounting

neck the mounting plate.  Retain the 4 screws

for re-assembly.

4

Install the mounting Plate to approved fan

brace and box combination use only the hard-

ware provided with the fan brace and box.

6

FAN BRACE AND BOX METHOD

Secure mounting plate directly to a joist from

the buliding structure via the two knock out

holes on the outlet box. Use only the appropri-

ate wood screws and washers included with

your fan. Caution: Wood screws must go

through into the building joist.

5

Wood

Screws

Mounting

Plate

Outlet box

BUILDING STRUCTURE METHOD

Содержание 5MQ60XX Series

Страница 1: ...Owner s Manual Ceiling Fan Installation Instructions For 5MQ60XX Series Fans READ AND SAVE THESE INSTRUCTIONS Total fan weight Quality Ceiling fans ...

Страница 2: ...f fuel burning equipment may be affected by this unit s operation Follow the heating equip ment manufacturer s guideline safety standards such as those published by the National Fire Protection Association NFPA and the American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE and the local code authorities Before servicing or cleaning unit Switch power off at Service panel a...

Страница 3: ...king the wire connections the wires should be spread apart with the grounded conductor and the equipment grounding conductor on one side of the outlet box and ungrounded conductor on the other side of the outlet box 17 Fan and light kit combinations over 70 lbs in both flush and downrod mode the safety cable must be installed into the house structure beams using the 3 lag screws washers and lock w...

Страница 4: ...e canopy with the two holes in the hanger bracket Secure with two screws provided 21 Light Switch Fan Switch Wall Control Re install safety bar removed in step 3 by placing safety bar on screws sliding into place and tight ening the 2 screws 20 Loosen 3 screws with key slots and remove 1 screw without slot from motor plate and save screw 25 Install 3 screws and washers per blade and tighten secure...

Страница 5: ... blade levels are not equal you can adjust blade levels by the following procedure To adjust a blade tip down insert a washer not sup plied between the blade and blade holder at the screw closest to the motor To adjust a blade tip up insert washer not supplied between the blade and blade holder at the two screws far thest from the motor Reverse the position of the washer if blades mount from top o...

Отзывы: