background image

Installation work and electrical wiring must be done by qualified person(s) in accordance with  applicable codes and standards (ANSI/NFPA 70-

1999), including fire-rated construction.

Use this unit only in the manner intended by the manufacturer.  If you have  any questions contact the manufacturer.

After making the wire connections, the wires should be spread apart with the grounded conductor and the equipment-grounding conductor on

one side of the outlet box and ungrounded conductor on the other side of the outlet box.

Before you begin installing the fan, Switch power off at Service panel and lock service disconnecting means to prevent power from being

switched on accidentally.  When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such  as a tag,

to the service panel.

Be cautious! read all instructions and safety information before installing your new fan. Review the accompanying assembly diagrams.

When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.

Make sure the installation site you choose allows the fan blades to rotate without any obstructions. Allow a minimum clearance of 7 feet from

the floor to the trailing edge of the blade.

To reduce the risk of fire, electric shock, or personal injury, mount to outlet box or supporting system acceptable for fan support. 

(Mounting must support at least 35 lbs. (16kg.)).

Do not bend blade holders during installation to motor, balancing or during cleaning.  Do not insert foreign object between rotating blades.

Attach the mounting bracket using only the hardware supplied with the outlet box.

To reduce the risk of fire or electric shock, do not use this fan with any solid state fan speed control device, or variable speed control.

If this unit is to be installed over a tub or shower, it must be marked as appropriate for the application.

NEVER place a switch where it can be reached from a tub or shower.

The combustion airflow needed for safe operation of fuel-burning equipment may be affected by this unit’s operation. Follow the heating equip-

ment manufacturer’s guideline safety standards such as those published by the National Fire Protection Association (NFPA), and the American

Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE) and the local code authorities.

Warning: Before attempting to replace the fuse make sure that the power is turned off to the fan. Replace only with 3 amp fuse.

Before servicing or cleaning unit, Switch power off at Service panel and lock service disconnecting means to prevent power from being switched

on accidentally.  When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such  as a tag, to the

service panel.

1.

2.

3.

4.

5.

6.

7.

8.

9.

10

11.

12.

13.

14.

15.

16.

Installation

WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS,

OBSERVE THE FOLLOWING: READ AND SAVE THESE INSTRUCTIONS

S

AFETY

T

IPS

TOOLS REQUIRED

Phillips Screwdriver      Wire Cutters       Pliers       Step Ladder

Before you begin installing the fan, Switch power off

at Service panel and lock service disconnecting means

to prevent power from being switched on accidentally.

When the service disconnecting means cannot be

locked, securely fasten a prominent warning device,

such  as a tag, to the service panel.

Before installing this fan make sure the outlet

box is properly installed to the house structure.

To reduce the risk of fire, electric shock, or per-

sonal injury, mount to outlet box or supporting

system acceptable for fan support. (Mounting

must support at least 35 lbs.(16 kg.)).

Install  the Mountiing Bracket to the Outlet box.

Use only the screws provided with the out-

let box.  

Install 4 x 40 watt candelabra base bulbs

included. 

3

2

1

4

Loosen 2 screws and remove pin with keeper

for downrod, yoke cover and canopy to fit in

yoke of fan.

6

Install downrod to canopy and then install yoke

cover to downrod. Thread wires and safety

cable through downrod

5

Содержание 5MMR54 Series

Страница 1: ...Quality Ceiling fans Owner s Manual Ceiling Fan Installation Instructions For 5MMR54 Series Fans READ AND SAVE THESE INSTRUCTIONS Total fan weight with light 5MMR54 CUL ENG ...

Страница 2: ...ion NEVER place a switch where it can be reached from a tub or shower The combustion airflow needed for safe operation of fuel burning equipment may be affected by this unit s operation Follow the heating equip ment manufacturer s guideline safety standards such as those published by the National Fire Protection Association NFPA and the American Society for Heating Refrigeration and Air Conditioni...

Страница 3: ...w away see insert The screws washers and motor pads are pre installed to the blade hold ers Attach blade assembly to motor and tight en screws securely 18 Set dip switches on the Remote T ransmitter and Remote Receiver to the same settings This must be done so the units will communcate properly If you have other fans you can set to control from one transmitter by setting both receivers the same as...

Страница 4: ...lass by locating dimples in light kit and aligning it with the groves in glass and twisting clockwise till tight 24 Install the 2 50 watt halogen bulbs Do not touch bulb surface as oily residue from skin can cause the bulb to explode 23 If you choose not to use light kit Loosen 3 screws with key slots and remove the 1 without slots Attach switch cap holder by placing over screws and twisting clock...

Страница 5: ...ll blade levels are not equal you can adjust blade levels by the following procedure To adjust a blade tip down insert a washer not supplied between the blade and blade holder at the screw closest to the motor To adjust a blade tip up insert washer not supplied between the blade and blade holder at the two screws farthest from the motor Reverse the position of the washer if blades mount from top o...

Отзывы: