3/2022

Remove every other screws from yoke 

located on top of fan assembly. Keep 

screws.

Note

: Flush mount is not available with 

vaulted ceiling. 

Reinstall the 3 set screws remove in step 

12. Tighten screws securely. 

To prepare the fan for wiring, hang fan 

onto mounting bracket by sliding the 

canopy over the mounting bracket hook 

(

Use one of non-slotted holes on the 

rim of the canopy

).

For Canadian installation and for USA fan 

and light kit combinations over 35 lbs, in 

both flush and downrod modes the safety 

cable must be installed into the house 

structure beams using 3” lag screws, 

washers and lock washers provided. 

Make sure that when the safety cable is 

fully extended the lead wires are longer 

than the cable and no stress is placed on 

the lead wires.

Note

: If Installing The Secondary Support 

Safety Cable in the U.S., Do Not Remove 
Knockouts In The Outlet Box.

 

Make wiring connections using wire 

connectors provided as indicated above.  

White from fan to White (Neutral) from 

house. Black and Blue from fan to Black 

(Live) from house. Connect all green 

grounded wires to Grounded wire from 

House. Make sure that no filaments are 

outside of the wire connectors.

After making the wire connections, the wires 

should be spread apart with the grounded 

conductor and the equipment-grounding 

conductor on one side of the outlet box and 

ungrounded conductor on the other side of 

the outlet box. The splices after being made 

should be turned upward and pushed carefully 

up into the outlet box.              

Remove side covers from canopy 

exposing  4 holes.  2 closed holes and 2 

open “L” shape holes. 

Place rubber pad and canopy over lead 

wire and safety cable and align the larger 

holes in canopy and holes on rubber pad 

with the set screws on yoke. 

 

Lag screw

Safety cable

Washer

Lock washer

SAFETY CABLE INSTALLATION

Wall switch

Power

source

White

(Natural)

Black

(Live)

Black

Blue

White

Grounded/Green

Flush Mount Installation

Side cover

Rubber pad 

Hook

Содержание 5LDO52 Series

Страница 1: ...R NAME RETAILER ADDRESS Attach sales receipt to this card and retain as your proof of purchase To register your fixture please visit our website www montecarlofans com 5LDO52XXXD Series Fan CUL Model NO 5LDO52XXD 8 3 kg 18 3 lbs Owner s Guide and Installation Manual ...

Страница 2: ...ut any obstructions Allow a minimum clearance of 7 feet from the floor to the trailing edge of the blade WARNING To Reduce The Risk Of Fire Electric Shock or Personal Injury Mount To Outlet Box Marked Acceptable for Fan Support of 15 9 kg 35 lbs or less And Use Mounting Screws Provided With The Outlet Box CAUTION For Compliance with Local Codes and Regulations If Installing The Secondary Support S...

Страница 3: ...nstall the mounting bracket onto the outlet box Partially loosen the two screws on the outlet box attach the mounting bracket onto the outlet box by sliding it over the two screws as shown in the illustration Have the mounting bracket in position and tighten the set screws Partially loosen downrod set screws from yoke at top of motor assembly Remove preassembled cross pin and keeper pin from downr...

Страница 4: ...provided as indicated above White from fan to White Neutral from house Black and Blue from fan to Black Live from house Connect all green grounded wires to Grounded wire from House Make sure that no filaments are outside of the wire connectors After making the wire connections the wires should be spread apart with the grounded conductor and the equipment grounding conductor on one side of the outl...

Страница 5: ...e Knockouts In The Outlet Box Make wiring connections using wire connectors provided as indicated above White from fan to White Neutral from house Black and Blue from fan to Black Live from house Connect all green grounded wires to Grounded wire from House Make sure that no filaments are outside of the wire connectors After making the wire connections the wires should be spread apart with the grou...

Страница 6: ...nstall the blade assembly to motor using the preinstalled screws Tighten screws securely Repeat this process for remaining blade assemblies Remove the set screws from switch housing cap on top of light fixture Keep screws Connect light lead wires White to white blue or black to black or blue Make sure the quick connectors are clasped firmly Align the pull chains from fan with the pull chain guides...

Страница 7: ...h appropriate holes in the final cap and push up Thread center pull chain through hole in finial and secure glass to light fixture by tightening the finial DO NOT OVER TIGHTEN the finial as glass may crack or break Setting the reverse switch in the down position will result in downward airflow and setting the switch in the up position will result in upward airflow Note Reverse switch must be set e...

Страница 8: ...ounting bracket or mounting plate are tightened securely to 4 Check that all blade holders are tightened securely to motor 5 Most fan wobble problems are caused when blade levels are unequal Check this level by selecting a point on the ceiling above the tip of one of the blades Measure this distance from blade tip to ceiling Keeping measure within 1 8 rotate the fan until the next blade is positio...

Страница 9: ...Mar 2022 ...

Отзывы: