background image

4

7

8

9

10

11

© 2022 Monte Carlo Fan Collections

3/2022

Install ball end of downrod into mounting 

bracket opening. Align (engage) slot on 

ball with tab on mounting bracket.

Warning:

 Failure to align slot on ball with 

tab may result in serious injury.

Important

: If using the angle mount, 

make sure open end of mounting bracket 

is installed facing the higher point of the 

ceiling and make sure the ceiling angle is 

not steeper than 20º.

 

For Canadian installation and for USA fan 

and light kit combinations over 35 lbs, in 

both flush and downrod modes the safety 

cable must be installed into the house 

structure beams using 3” lag screws, 

washers and lock washers provided. 

Make sure that when the safety cable is 

fully extended the lead wires are longer 

than the cable and no stress is placed on 

the lead wires.

Note

: If Installing The Secondary Support 

Safety Cable in the U.S., Do Not Remove 
Knockouts In The Outlet Box.

  

Make wiring connections using wire 

connectors provided as indicated above.  

White from fan to White (Neutral) from 

house. Black and Blue from fan to Black 

(Live) from house. Connect all green 

grounded wires to Grounded wire from 

House. Make sure that no filaments are 

outside of the wire connectors.

After making the wire connections, the wires 

should be spread apart with the grounded 

conductor and the equipment-grounding 

conductor on one side of the outlet box and 

ungrounded conductor on the other side of 

the outlet box. The splices after being made 

should be turned upward and pushed carefully 

up into the outlet box.              

Lift Canopy allowing the 2 studs to 

protrude through the canopy.

Next lift the cover ring and install knurled 

nuts as shown. Tighten the knurled nuts 

securely. The canopy should adjust for 

any irregularity in the ceiling or Outlet 

box.

Make sure the studs protruding from the 

bottom of the Mounting bracket are 

installed with threads all the way through 

the bracket.    

SAFETY CABLE INSTALLATION

Lag screw

Safety cable

Washer

Lock washer

Tab

Slot

Go to step 

19 t

o finish 

installation

Wall 

switch

Power

source

White

(Neutral)

Black

(Live)

Ground/Green

Black

Blue

White

Stud

Grounded

wires

Ungrounded

wires

Содержание 5LD52 Series

Страница 1: ...ME RETAILER ADDRESS Attach sales receipt to this card and retain as your proof of purchase To register your fixture please visit our website www montecarlofans com 5LD52XXX Series Fan CUL Model NO 5LD52XX 6 3 kg 13 86 lbs Owner s Guide and Installation Manual ...

Страница 2: ... choose allows the fan blades to rotate without any obstructions Allow a minimum clearance of 7 feet from the floor to the trailing edge of the blade WARNING To Reduce The Risk Of Fire Electric Shock or Personal Injury Mount To Outlet Box Marked Acceptable for Fan Support of 15 9 kg 35 lbs or less And Use Mounting Screws Provided With The Outlet Box CAUTION For Compliance with Local Codes and Regu...

Страница 3: ...ox will cause the fan to wobble Install the mounting bracket onto the outlet box Partially loosen the two screws on the outlet box attach the mounting bracket onto the outlet box by sliding it over the two screws as shown in the illustration Have the mounting bracket in position and tighten the set screws Partially loosen downrod set screws from yoke at top of motor assembly Remove preassembled cr...

Страница 4: ...ided as indicated above White from fan to White Neutral from house Black and Blue from fan to Black Live from house Connect all green grounded wires to Grounded wire from House Make sure that no filaments are outside of the wire connectors After making the wire connections the wires should be spread apart with the grounded conductor and the equipment grounding conductor on one side of the outlet b...

Страница 5: ...e Knockouts In The Outlet Box Make wiring connections using wire connectors provided as indicated above White from fan to White Neutral from house Black and Blue from fan to Black Live from house Connect all green grounded wires to Grounded wire from House Make sure that no filaments are outside of the wire connectors After making the wire connections the wires should be spread apart with the grou...

Страница 6: ...lade by 3 blade screws and washers provided Tighten screws securely Repeat this process for remaining blades Remove shipping stabilizers from motor assembly Install the blade assembly to motor using the preinstalled screws Tighten screws securely Repeat this process for remaining blade assemblies Setting the reverse switch in the down position will result in downward airflow and setting the switch...

Страница 7: ...ounting bracket or mounting plate are tightened securely to 4 Check that all blade holders are tightened securely to motor 5 Most fan wobble problems are caused when blade levels are unequal Check this level by selecting a point on the ceiling above the tip of one of the blades Measure this distance from blade tip to ceiling Keeping measure within 1 8 rotate the fan until the next blade is positio...

Страница 8: ...Mar 2022 ...

Отзывы: