While the fan assembly is still on the
ground thread the safety cable through
the mounting bracket.
safety cable
mounting
bracket
Lift fan assembly and install the safety cable
directly to the building structure using the 3"
lag screw and plain washer provided. Before
proceeding to the next step make sure that
the cable is properly installed and will
support the fan weight. Make sure the
screw washer and safety cable are
installed using the order pictured above.
4
Ball
Notch
A
5
Install mounting bracket to outlet box in
ceiling using the screws provided with
the outlet box and washers.
1
Feed motor lead wires through downrod/
canopy assembly and insert downrod into
motor yoke. Next, insert clevis pin
through yoke and downrod and secure
with cotter pin. (see inset) Tighten both
yoke set screws to further secure
downrod.
Clevis
Pin
Set
Screws
Cotter
Pin
Ridge
plain
washer
safety cable
3" lag
screw
Set screw
Canadian Mounting System Insert
WARNING: MOUNT ONLY TO AN OUTLET BOX MARKED
ACCEPTABLE FOR FAN SUPPORT
All set screws must be checked and retightened where necessary before
installation.
Canadian Safety Tips
A. Carefully lift fan assembly onto mounting
bracket. Rotate fan so that the notch on
the ball engages the ridge in the
mounting bracket. This will allow
hands-free wiring. For wiring instruc-
tions please refer to page 4 step #7.