background image

Installation work and electrical wiring must be done by qualified person(s) in accordance with  applicable codes and standards (ANSI/NFPA 70-

1999), including fire-rated construction.

Use this unit only in the manner intended by the manufacturer.  If you have  any questions contact the manufacturer.

After making the wire connections, the wires should be spread apart with the grounded conductor and the equipment-grounding conductor on

one side of the outlet box and ungrounded conductor on the other side of the outlet box.

Before you begin installing the fan, Switch power off at Service panel and lock service disconnecting means to prevent power from being

switched on accidentally.  When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such  as a tag,

to the service panel.

Be cautious! read all instructions and safety information before installing your new fan. Review the accompanying assembly diagrams.

When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.

Make sure the installation site you choose allows the fan blades to rotate without any obstructions. Allow a minimum clearance of 7 feet from

the floor to the trailing edge of the blade.

WARNING – Risk of fire, electric shock, or personal injury, The fan in this box may be either directly supported from a structural framing mem-

ber of a building and/or may be mounted to an outlet box marked acceptable for fan support of 31.8 kg. (70 lbs.) or less. Most outlet boxes

commonly used for the support of luminaires may not be acceptable for fan support and may need to be replaced. Consult a qualified electrician

if in doubt.

Do not bend blade holders during installation to motor, balancing or during cleaning.  Do not insert foreign object between rotating blades.

Attach the mounting bracket using only the hardware supplied with the outlet box.

To reduce the risk of fire or electric shock, do not use this fan with any solid state fan speed control device, or variable speed control.

If this unit is to be installed over a tub or shower, it must be marked as appropriate for the application.

NEVER place a switch where it can be reached from a tub or shower.

The combustion airflow needed for safe operation of fuel-burning equipment may be affected by this unit’s operation. Follow the heating equip-

ment manufacturer’s guideline safety standards such as those published by the National Fire Protection Association (NFPA), and the American

Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE) and the local code authorities.

Warning: Before attempting to replace the fuse make sure that the power is turned off to the fan. Replace only with 3 amp fuse.

Before servicing or cleaning unit, Switch power off at Service panel and lock service disconnecting means to prevent power from being switched

on accidentally.  When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such  as a tag, to the

service panel.

1.

2.

3.

4.

5.

6.

7.

8.

9.

10

11.

12.

13.

14.

15.

16.

Installation

WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS,

OBSERVE THE FOLLOWING: READ AND SAVE THESE INSTRUCTIONS

S

AFETY

T

IPS

TOOLS REQUIRED

Phillips Screwdriver      Wire Cutters       Pliers       Step Ladder

Before you begin installing the fan, Switch power off

at Service panel and lock service disconnecting means

to prevent power from being switched on accidentally.

When the service disconnecting means cannot be

locked, securely fasten a prominent warning device,

such  as a tag, to the service panel.

1

Warning

-Risk of fire, electric shock, or personal

injury. The fan in this box may be either directly

supported from a structural framing member of a

building and/or may be mounted to an outlet box

marked acceptable for fan support of of 31.8 kg (70

lbs) or less. Most outlet boxes commonly used for

the support of lumminaires may not be acceptable

for fan support and may need to be replaced.

Consult a qualified electrician if in doubt. 

2

OUTLET BOX METHOD

Remove Safety bar from mounting bracket by

loosing screws, sliding bar to side, and lifting it

off the 2 screws.

3

Secure mounting plate directly to a joist from the

buliding structure via the two knock out holes on

the outlet box. Use only the appropriate wood

screws and washers included with your fan.

Caution: Wood screws must go through into the

building joist.

5

Outlet box

Mounting

Plate

Wood

Screws

BUILDING STRUCTURE METHOD

Remove the 4 screws attaching the Mounting

neck the mounting plate.  Retain the 4 screws

for re-assembly.

4

Install the mounting Plate to approved fan

brace and box combination use only the hard-

ware provided with the fan brace and box.

6

FAN BRACE AND BOX METHOD

Содержание 5KBR54 Series

Страница 1: ...Quality Ceiling fans Owner s Manual Ceiling Fan Installation Instructions For 5KBR54 Series Fans READ AND SAVE THESE INSTRUCTIONS Total fan weight with light ...

Страница 2: ... fuel burning equipment may be affected by this unit s operation Follow the heating equip ment manufacturer s guideline safety standards such as those published by the National Fire Protection Association NFPA and the American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE and the local code authorities Warning Before attempting to replace the fuse make sure that the power...

Страница 3: ...eper for downrod yoke cover and canopy to fit in yoke of fan 11 Install canopy and yoke cover onto downrod as shown Thread wires and safety cable through downrod 10 Set dip switches on the Remote T ransmitter and Remote Receiver to the same settings This must be done so the units will communcate properly If you have other fans you can set to control from one transmitter by setting both receivers t...

Страница 4: ...pment grounding conductor on one side of the outlet box and ungrounded conductor on the other side of the outlet box 20 Attach blade brackets to blades using the blade bracket screws and washers provided 23 Remove the shipping stabilizer plate and throw away see insert The screws washers and motor pads are pre installed to the blade hold ers Attach blade assembly to motor and tighten screws secure...

Страница 5: ...Lower lights press and hold D L button To turn off either up or down light press and quickly release either U L or D L button Press button marked REV to reverse the rotation direction of the fan blades Fan speed control but tons Fan on off Light dim mer for up and down lights Fan reverse button 35 Remove cover by snaping off from top or bottom Install 12V battery into wall remote Duracell MN21 Eve...

Страница 6: ...ll blade levels are not equal you can adjust blade levels by the following procedure To adjust a blade tip down insert a washer not supplied between the blade and blade holder at the screw closest to the motor To adjust a blade tip up insert washer not supplied between the blade and blade holder at the two screws farthest from the motor Reverse the position of the washer if blades mount from top o...

Отзывы: