background image

Installation work and electrical wiring must be done by qualified person(s) in accordance with  applicable codes ANSI/NFPA 70-1999),

including fire-rated construction.

Use this unit only in the manner intended by the manufacturer.  If you have  any questions contact the manufacturer.

After making the wire connections, the wires should be spread apart with the grounded conductor and the equipment-grounding con-

ductor on one side of the outlet box and ungrounded conductor on the other side of the outlet box.

Before you begin installing the fan, Switch power off at Service panel and lock service disconnecting means to prevent power from

being switched on accidentally.  When the service disconnecting means cannot be locked, securely fasten a prominent warning device,

such  as a tag, to the service panel.

Be cautious! read all instructions and safety information before installing your new fan. Review the accompanying assembly diagrams.

When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.

Make sure the installation site you choose allows the fan blades to rotate without any obstructions. Allow a minimum clearance of 7

feet from the floor to the trailing edge of the blade.

To reduce the risk of fire, electric shock, or personal injury, mount to outlet box or supporting system acceptable for fan support. 

(Mounting must support at least 35 lbs.)

Do not bend blade holders during installation to motor, balancing or during cleaning.  Do not insert foreign object between rotating

blades.

Attach the mounting bracket using only the hardware supplied with the outlet box.

To reduce the risk of fire or electric shock, do not use this fan with any solid state fan speed control device, or variable speed control.

If this unit is to be installed over a tub or shower, it must be marked as appropriate for the application.

NEVER place a switch where it can be reached from a tub or shower.

The combustion airflow needed for safe operation of fuel-burning equipment may be affected by this unit’s operation. Follow the heat-

ing equipment manufacturer’s guideline safety standards such as those published by the National Fire Protection Association (NFPA),

and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE) and the local code authorities.

Before servicing or cleaning unit, Switch power off at Service panel and lock service disconnecting means to prevent power from being

switched on accidentally.  When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such

as a tag, to the service panel.

1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

11.

12.

13.

14.

15.

WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS,

OBSERVE THE FOLLOWING: READ AND SAVE THESE INSTRUCTIONS

s

aFeTy

T

Ips

TOOls reQuIred

Phillips Screwdriver      Wire Cutters       Pliers      Step Ladder

Before you begin installing the fan, Switch

power off at Service panel and lock service dis-

connecting means to prevent power from being

switched on accidentally.  When the service dis-

connecting means cannot be locked, securely

fasten a prominent warning device, such as a

tag, to the service panel.

Before installing this fan make sure the outlet box is
properly installed to the house structure.  To reduce
the risk of fire, electric shock, or personal injury,
mount to outlet box or supporting system acceptable
for fan support. (Mounting must support at least 35
lbs.)

Use metal outlet box suitable for fan support
(must support 35 lbs). Before attaching fan to
outlet box, ensure the outlet box is securley
fastened by at least two points to a structural
ceiling member ( a loose box will cause the fan
to wabble).  

use only the screws provided

with the outlet box.  

Insert downrod into yoke on top of the Fan
Body.  Align the hole in the Downrod with the
hole in the Yoke. Insert the Pin through the
Yoke and Downrod until the point appears on
the other side.  Install the Keeper Pin

Tighten the 2 Set screws on the Yoke

once the downrod is in place. Check

motor for shipping stabilizers and

remove if present.

Tread leadwires and safety cable first

through the canopy disk, Canopy and

lastly downrod.

3

2

1

5

6

4

Canopy disk

Downrod

Canopy

Yoke

Cross Pin

Keeper 

Pin

Installation

Содержание 5hM52XX series

Страница 1: ...Ceiling Fan Installation Instructions For 5hM52XX series Fans read and save These InsTrucTIOns Total fan weight Owner s Manual ...

Страница 2: ...y be affected by this unit s operation Follow the heat ing equipment manufacturer s guideline safety standards such as those published by the National Fire Protection Association NFPA and the American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE and the local code authorities Before servicing or cleaning unit Switch power off at Service panel and lock service disconnecti...

Страница 3: ...e of the outlet box Canadian mounting only Safety Cable Lag Screw 11 Make sure the studs protruding from the bottom of the Mounting bracket are installed with threads all the way through the bracket 9 Pass leadwires and safety cable through the canopy Remove side covers from canopy expos ing 4 holes 2 closed holes and 2 open L shape holes 17 16 Lift Conopy allowing the 2 studs to protrude through ...

Страница 4: ...rce using wire nuts provided Make sure that no filiments are outside of the wirenut After making the wire connections the wires should be spread apart with the grounded con ductor and the equipment grounding conductor on one side of the outlet box and ungrounded conductor on the other side of the outlet box 23 Connect black and blue wire from fan to Black or Hot wire from house Connect White wire ...

Страница 5: ...Check this level by selecting a point on the ceiling above the tip of one of the blades Measure this distance from blade tip to ceilng Keeping measure within 1 8 rotate the fan until the next blade is positioned for measure ment Repeat for each blade If all blade levels are not equal you can adjust blade levels by the fol lowing procedure To adjust a blade tip down insert a washer not supplied bet...

Страница 6: ...manuel de l utIlIsateur Instructions pour l installation d un ventilateur de plafond Por 5HM52XX Serie ventilateur LIRE ET GARDER CES INSTRUCTIONS Poids total du ventilateur et du kit d éclairage ...

Страница 7: ... la mise en marche de cette unité suivre les directives et appliquer les normes de sécurité indiquées par le fabricant d un tel équipement comme celles communiquées par l association nationale de la Protection contre les Incendies nePa et par les Ingénieurs de l association américaine du Chauffage de la réfrigération et de l air Climatisé asHrae et par les autorités responsables des codes locaux 1...

Страница 8: ... montage destiné au Canada uniquement câble de sécurité Vis à bois à tête carrée 11 assurez vous que les goujons filetés dépassant de la partie inférieure du sup port de suspension sont installés avec les filets bien enfoncés à travers le support 9 Faites passer les fils de connexion et le câble de sécurité à travers la gar niture retirez les couvercles de la garniture qui exposent 4 trous 2 trous...

Страница 9: ...d énergie en utilisant les capuchons élec triques fournis à cet effet assurez vous qu aucun filament ne dépasse des capu chons électriques après avoir établi les liaisons électriques vous devez étaler les fils en mettant le conducteur mis à la masse et le conducteur de mise à la terre de l appareillage d un côté du boîtier de sortie de courant et le conducteur non mis à la terre de l autre côté de...

Страница 10: ... Vérifiez ce niveau en sélectionnant un point du plafond situé juste au dessus de l extrémité d une des pales mesurez la distance entre la pale et le plafond Faites tourner le ventilateur jusqu à ce que la pale suivante vienne se placer au point de repère et mesurez la distance à 3 mm près répétez cette opération pour chaque pale si toutes les pales ne sont pas au même niveau vous pouvez ajuster l...

Отзывы: