background image

1.Check main and branch circuit fuses or circuit breakers.

2.Check line wire connections to fan and switch wire connections in switch housing.

CAUTION:  Make sure main power is turned off.

3.Make sure forward/reverse switch is firmly in up or down position.  Fan will not operate when

switch is in the middle.

1.Check to make sure all screws in motor housing are snug (not over tightened).

2.Check to make sure the screws which attach the fan blade holder to the motor are tight.

3.Check to make sure wire nut connectors in switch housing are not rattling against each other or

against the interior wall of the switch housing.

CAUTION:  Make sure main power is turned off before entering switch housing.

4.Some fan motors are sensitive to signals from Solid State variable speed controls.  

5.Allow "break-in" period of 24 hours.  Most noises associated with a new fan will disappear after

this period.

1.Make sure that the ridge of the canopy engages the notch in the downrod ball.  (See illustration in

Step #6 of Downrod Mount installation).

2.Check that all blades are screwed firmly into blade holders.

3.Check that all blade holders are tightened securely to motor.

4.Make sure that canopy and mounting bracket are tightened securely to ceiling junction box and

junction box is mounted firmly to ceiling joist.

5.Most fan wobble problems are caused when blade levels are unequal. Check this level by selecting

a point on the ceiling above the tip of one of the blades. Measure this distance from blade tip to

ceilng. Keeping measure within 1/8", rotate the fan until the next blade is positioned for measure-

ment. Repeat for each blade. If all blade levels are not equal, you can adjust blade levels by the fol-

lowing procedure. To adjust a blade tip down, insert a washer (not supplied) between the blade and

blade holder at the screw closest to the motor. To adjust a blade tip up, insert washer (not supplied)

between the blade and blade holder at the two screws farthest from the motor.  Reverse the position

of the washer if blades mount from top of blade.

6.If blade wobble is still noticeable, interchanging two adjacent (side by side) blades can redistribute

the weight and possibly result in smoother operation.

1.Check blue wire from fan to make sure it is connected to hot wire from house.

2.Check for loose or disconnected wires in fan switch housing.

3.Check for loose or disconnected wires in light kit.

4.Check for faulty light bulbs.

WARNING: Over lamping the fan will result in the fan lights shutting down until

the proper wattage of bulbs are installed.

Reset the lights by turning off the wall switch, breaker,or by remote. Replace bulbs with

the correct wattage bulbs, turn the power on.

CAUTION:  Make sure main power is turned off before entering switch housing.

User Servicing Instructions

WARNING: Before attempting to replace the fuse make sure the main power is turned off

to the fan. (Fuse is inside the canopy on the blue wire to remote receiver, push and twist

the cap to open the fuse case) Push and twist to reassemble fuse.

Risk of fire. Replace fuse only with 3 amp, 125 volt fuse.

2. If fan sounds noisy:

1. If fan does not start:

3. If fan wobbles:

4. If light does not work:

T

ROUBLE

S

HOOTING

If you have difficulty operating your new ceiling fan, it may be the result of incorrect assembly, installation, or wiring. In

some cases, these installation errors may be mistaken for defects. If you experience any faults, please check this Trouble

Shooting Chart. If a problem cannot be remedied, or you are experiencing difficulty in installation, please call our

Customer Service Center at the 

number printed on your parts list insert sheet. 

Warning: Before servicing or cleaning unit, Switch power off at Service panel and lock service disconnecting

means to prevent power from being switched on accidentally.  When the service disconnecting means cannot

be locked, securely fasten a 

prominent warning device, such  as a tag, to the service panel.

Customer Service Center:

301 West Washington St. 

Riverside, NJ 08075

1-800-519-4092

www.montecarlofans.com

Содержание 5FNR60 Series

Страница 1: ...OWNER S MANUAL Ceiling Fan Installation Instructions Total fan weight with light READ AND SAVE THESE INSTRUCTIONS For 5FNR60XXD L Series Fans ...

Страница 2: ...e service panel Be cautious read all instructions and safety information before installing your new fan Review the accompanying assembly diagrams When cutting or drilling into wall or ceiling do not damage electrical wiring and other hidden utilities Make sure the installation site you choose allows the fan blades to rotate without any obstructions Allow a minimum clearance of 7 feet from the floo...

Страница 3: ...tches on the Remote Transmitter and Remote Receiver to the same settings This must be done so the units will communicate properly If you have other fans you can set to control from one trans mitter by setting both receivers the same as the transmitter If you have more than one fan with remote You can set the dip switches to different posi tions to have seperate control 17 Remote Transmitter Dip sw...

Страница 4: ...n to black wire from light kit 26 Lift canopy allowing the 2 studs to pro trude through the canopy and install the knurled nuts as shown Tighten the knurled nuts securely The canopy should adjust for any irregularity in the ceiling or Outlet box 21 Make wire connections to power source using wire nuts provided Make sure that no filiments are outside of the wirenut After making the wire connections...

Страница 5: ...nt cover Attach hand remote cover the by placing over 4 pins and snapping into place 31 HAND HELD INSTALL Install wall control unit to outlet box using machine screws provided 32 WALL MOUNT INSTALL Attach the wall trim plate to the wall control with the screws provided Snap battery cover in place 33 ...

Страница 6: ...light dimmer The light will cycle from bright to dim to bright until button is released Light will maintain last setting if turned off FORWARD REVERSE Depress rev button allow a few seconds for remote to change rotation direction with fan running HIGH SPEED MEDIUM SPEED LOW SPEED FAN OFF SETTING Turns fan off only FAN REVERSE Press once to change direction of the fan Fanmust be running to reverse ...

Страница 7: ...blade holder at the two screws farthest from the motor Reverse the position of the washer if blades mount from top of blade 6 If blade wobble is still noticeable interchanging two adjacent side by side blades can redistribute the weight and possibly result in smoother operation 1 Check blue wire from fan to make sure it is connected to hot wire from house 2 Check for loose or disconnected wires in...

Отзывы: