Hang assembled fan from the mounting bracket in-
stalled to ceiling in previous step.  Make sure the fan
is hanging straight.  Rotate fan until the tab on the
Mounting bracket engages the slot on the Downrod
Ball.  This must be done to prevent the fan body from
rotating when the blades are in motion.

11

Make wire connections to power source using wire nuts
provided.  Make sure that no filiments are outside of
the wirenut. After making the wire connections, the
wires should be spread apart with the grounded con-
ductor and the equipment-grounding conductor on one
side of the outlet box and ungrounded conductor on the
other side of the outlet box.  

15

Make sure the studs protruding from the

bottom of the Mounting bracket are in-

stalled with threads all the way through

the bracket.  

13

Tighten the 2 set screws on the yoke

once the downrod is in place.

10

Make wiring connections as indicated

above.  Connect black and blue wire from

fan to Black or (Hot) wire from house.

Connect White wire from Fan to White

(Neutral) wire from house.  Connect

Ground leads from mounting bracket and

downrod to Ground lead from house.

Refer to Safety Tips section of manual.

14

For Canadian installation and for USA fan and light

kit combinations over 35 lbs, in both flush and

downrod modes the safety cable must be installed

into the house structure beams using 3” lag

screws, washers and lock washers provided. Make

sure that when the safety cable is fully extended

the lead wires are longer than the cable and no

stress is placed on the lead wires.

Note

:If Installing The Secondary Support Safety

Cable in the U.S., Do Not Remove Knockouts In

The Outlet Box.  

12

Safety cable installation

Safety Cable

Lag Screw

safety

cable

3” lag

screw

lock

washer

washer

Remove every other screw as circled

and save for later use.

Note

: Flushmount is not available

with vaulted ceiling.

17

Go to step 26

Flush mount installation

16

Cover 

Ring

Lift Conopy allowing the 2 studs to

protrude through the canopy.

Next lift the cover ring and install knurled

nuts as shown. Tighten the knurled nuts

securely. The canopy should adjust for

any irregularity in the ceiling or Outlet

box.

Содержание 5DI44

Страница 1: ...this card and retain as your proof of purchase DATE OF PURCHASE MODEL NUMBER RETAILER NAME RETAILER ADDRESS To register your fixture please visit our website www montecarlofans com Total fan weight with light 5DI44XXD Series Fan UL Model No 5DI44 7 9 kgs 17 38 lbs ...

Страница 2: ...Use Mounting Screws Provided With The Outlet Box CAUTION For Compliance with Local Codes and Regulations If Installing The Secondary Support Safety Cable in the U S Do Not Re move Knockouts In The Outlet Box Mount the secondary support safety cable through the reserved nail screw hole on the outlet box to the building structure or the ceiling joist WARNING To reduce the risk of personal injury do ...

Страница 3: ...tlet box ensure the outlet box is securley fastened by at least two points to a structural ceiling member a loose box will cause the fan to wabble Use only the screws provided with the outlet box 3 2 1 Loosen the 2 set screws till you can not feel them on inside of yoke Note If install fan on vaulted ceiling make sure open end of mounting bracket is installed facing the higher point of the ceiling...

Страница 4: ...r Hot wire from house Connect White wire from Fan to White Neutral wire from house Connect Ground leads from mounting bracket and downrod to Ground lead from house Refer to Safety Tips section of manual 14 For Canadian installation and for USA fan and light kit combinations over 35 lbs in both flush and downrod modes the safety cable must be installed into the house structure beams using 3 lag scr...

Страница 5: ...screws from hardware pack and install one on each side of bracket to match the L slot screw holes in canopy Keep 2 screws for later use 22 Make wire connections to power source using wire nuts provided Make sure that no filiments are outside of the wirenut After making the wire connections the wires should be spread apart with the grounded con ductor and the equipment grounding conductor on one si...

Страница 6: ...he fan will re sult in the fan lights shutting down until the proper wattage of bulbs are installed Reset the lights by turning off the wall switch breaker or by remote Replace bulbs with the correct wattage bulbs turn the power on 33 30 Attach glass by locating dimples in light fixture with the groves in glass and twisting clockwise till tight 34 Setting the reverse switch in the left hand side w...

Страница 7: ...ure this distance from blade tip to ceilng Keeping measure within 1 8 rotate the fan until the next blade is posi tioned for measurement Repeat for each blade If all blade levels are not equal you can ad just blade levels by the following procedure To adjust a blade tip down insert a washer not supplied between the blade and blade holder at the screw closest to the motor To adjust a blade tip up i...

Страница 8: ...Apr 2013 May 2013 CUL requirement Aug 2013 dual mount ...