background image

6

© 2017 Monte Carlo Fan Company

09/2017

  Trouble Shooting

or wiring. In some cases, these installation errors may be mistaken for defects. If you experience any faults, 

installation, please call our Customer Service Center at the 

number printed on your parts list insert sheet. 

Warning

: Before servicing or cleaning unit, Switch power off at Service panel and lock service disconnecting 

means to prevent power from being switched on accidentally. When the service disconnecting means cannot be 

locked, securely fasten a prominent warning device, such  as a tag, to the service panel.

1.Check main and branch circuit fuses or circuit breakers.

2.Check line wire connections to fan and switch wire connections in switch housing.

CAUTION

: Make sure main power is turned off.

either way. Fan will not operate when switch is in the middle.

4.If this fan uses remote controller, make sure dip switches are setting properly and make 

sure battery is effective. 

1.Check to make sure all screws in motor housing are snug (not over tightened).

2.Check to make sure the screws which attach the fan blade holder to the motor are tight.

3.Check to make sure wire nut connectors in switch housing are not rattling against each 

other or against the interior wall of the switch housing.

CAUTION

: Make sure main power is turned off before entering switch housing.

4.Check to be sure light bulb is tight in socket and not touching the glass shade.

5.Some fan motors are sensitive to signals from Solid State variable speed controls.  

6.Allow "break-in" period of 24 hours.  Most noises associated with a new fan will disappear 

after this period.

1.If this is a downrod mount fan, make sure the ridge on mounting bracket engages the 

notch in the downrod ball.

2.Make sure that canopy, mounting bracket or mounting plate are tightened securely to 

4.Check that all blade holders are tightened securely to motor.

5.Most fan wobble problems are caused when blade levels are unequal. Check this level by 

selecting a point on the ceiling above the tip of one of the blades. Measure this distance 

from blade tip to ceilng. Keeping measure within 1/8", rotate the fan until the next blade 

is positioned for measurement. Repeat for each blade. If all blade levels are not equal, 

you can adjust blade levels by the following procedure. To adjust a blade tip down, insert 

a washer (not supplied) between the blade and blade holder at the screw closest to the 

motor. To adjust a blade tip up, insert washer (not supplied) between the blade and blade 

holder at the two screws farthest from the motor. Reverse the position of the washer if 

blades mount from top of blade.

6.If blade wobble is still noticeable, interchanging two adjacent (side by side) blades can 

redistribute the weight and possibly result in smoother operation.

1.Check blue wire from fan to make sure it is connected to hot wire from house.

2.Check for loose or disconnected wires in fan switch housing.

3.Check for loose or disconnected wires in light kit.

4.Check for faulty light bulb and make sure bulb is tight in socket.

5.Remove light kit and check the plug connections if they are present.

6.If this fan uses remote controller, make sure dip switches are setting properly and make 

sure battery is effective. 

 

CAUTION

: Make sure main power is turned off before entering switch housing and/or 

canopy.

                                       

                               

2. If fan sounds noisy:

3. If fan wobbles:

4. If light does not work:

1. If fan does not start:

Trouble

Suggested Remedy

Содержание 4TK52 Series

Страница 1: ...TE OF PURCHASE MODEL NUMBER RETAILER NAME RETAILER ADDRESS Attach sales receipt to this card and retain as your proof of purchase To register your fixture please visit our website www montecarlofans com 4TK52XX Series Fan UL Model NO 4TK52XX 6 5 kgs 14 3 lbs ...

Страница 2: ...t any obstructions Allow a minimum clearance of 7 feet from the floor to the trailing edge of the blade WARNING To Reduce The Risk Of Fire Electric Shock or Personal Injury Mount To Outlet Box Marked Acceptable for Fan Support of 15 9 kg 35 lbs or less And Use Mounting Screws Provided With The Outlet Box CAUTION For Compliance with Local Codes and Regulations If Installing The Secondary Support Sa...

Страница 3: ...points to a structural ceiling member a loose box will cause the fan to wobble Remove the two outlet box screws provided with the box aligning the holes of the mounting bracket with the holes of the outlet box Reinstall the 2 outlet box screws securely Partially loosen downrod set screws from yoke at top of motor assembly Remove preassembled cross pin and keeper pin from downrod Place downrod over...

Страница 4: ...Black Live from house Connect all green grounded wires to Grounded wire from House Make sure that no filaments are outside of the wire connectors After making the wire connections the wires should be spread apart with the grounded conductor and the equipment grounding conductor on one side of the outlet box and ungrounded conductor on the other side of the outlet box The splices after being made s...

Страница 5: ...ng blade assemblies Setting the reverse switch in the down position will result in downward airflow and setting the switch in the up position will result in upward airflow Note Reverse switch must be set either way completely If the reverse switch is set in the middle position fan will not operate Install pull chain to preassembled pull chain on fan Pull chains provided Shipping stabilizers Revers...

Страница 6: ... If this is a downrod mount fan make sure the ridge on mounting bracket engages the notch in the downrod ball 2 Make sure that canopy mounting bracket or mounting plate are tightened securely to 4 Check that all blade holders are tightened securely to motor 5 Most fan wobble problems are caused when blade levels are unequal Check this level by selecting a point on the ceiling above the tip of one ...

Страница 7: ...Sep 2017 ...

Отзывы: