background image

© 2013 Monte Carlo Fan Company

6/15/2013

7

1.Check main and branch circuit fuses or circuit breakers.

2.Check line wire connections to fan and switch wire connections in switch housing.

CAUTION:  Make sure main power is turned off.

3.Make sure forward/reverse switch is firmly in up or down position.  Fan will not operate

when switch is in the middle.

4.Make sure that shipping stabilizer tabs have been removed from motor.

1.Check to make sure all screws in motor housing are snug (not over tightened).

2.Check to make sure the screws which attach the fan blade holder to the motor are tight.

3.Check to make sure wire nut connectors in switch housing are not rattling against each

other or against the interior wall of the switch housing.

CAUTION:  Make sure main power is turned off before entering switch housing.

4.If using an optional Ceiling Fan Light Kit, check to be sure the screws securing the glass-

ware are finger tight.  Check to be sure light bulb is tight in socket and not touching glass

shade(s). If vibration persists from glass, remove glass and install a 1/4" wide rubber band

on glass neck to act as an insulator. Replace glass and tighten screws against rubber band. 

5.Some fan motors are sensitive to signals from Solid State variable speed controls.  

DO NOT USE a Solid State variable speed control.

6.Allow "break-in" period of 24 hours.  Most noises associated with a new fan will disappear

after this period.

1.If this is a downrod mount fan, make sure the ridge on mounting bracket engages the

notch in the downrod ball.

2.Check that all blades are screwed firmly into blade holders.

3.Check that all blade holders are tightened securely to motor.

4.Make sure that canopy and mounting bracket are tightened securely to ceiling junction

box and junction box is mounted firmly to ceiling joist.

5.Most fan wobble problems are caused when blade levels are unequal. Check this level by

selecting a point on the ceiling above the tip of one of the blades. Measure this distance

from blade tip to ceilng. Keeping measure within 1/8", rotate the fan until the next blade is

positioned for measurement. Repeat for each blade. If all blade levels are not equal, you

can adjust blade levels by the following procedure. To adjust a blade tip down, insert a

washer (not supplied) between the blade and blade holder at the screw closest to the motor.

To adjust a blade tip up, insert washer (not supplied) between the blade and blade holder at

the two screws farthest from the motor.  Reverse the position of the washer if blades mount

from top of blade.

6.If blade wobble is still noticeable, interchanging two adjacent (side by side) blades can re-

distribute the weight and possibly result in smoother operation.

1.Check blue wire from fan to make sure it is connected to hot wire from house.

2.Check for loose or disconnected wires in fan switch housing.

3.Check for loose or disconnected wires in light kit.

4.Check for faulty light bulbs.

CAUTION:  Make sure main power is turned off before entering switch housing.

2. If fan sounds noisy:

1. If fan does not start:

3. If fan wobbles:

4. If light does not work:

T

ROUBLe

S

HOOTING

If you have difficulty operating your new ceiling fan, it may be the result of incorrect assembly, installation, or

wiring. In some cases, these installation errors may be mistaken for defects. If you experience any faults, please

check this Trouble Shooting Chart. If a problem cannot be remedied, or you are experiencing difficulty in installa-

tion, please call our Customer Service Center at the 

number printed on your parts list insert sheet. 

Warning: Before servicing or cleaning unit, Switch power off at Service panel and lock service discon-

necting means to prevent power from being switched on accidentally.  When the service disconnecting

means cannot be locked, securely fasten a 

prominent warning device, such  as a tag, to the service panel.

Trouble

Suggested Remedy

Содержание 4MC20XX Series

Страница 1: ...ipt to this card and retain as your proof of purchase DATE OF PURCHASE MODEL NUMBER RETAILER NAME RETAILER ADDRESS To register your fixture please visit our website www montecarlofans com 4MC20XX Series Fan Total fan weight UL Model No 4MC20 4 5 kgs 9 9 lbs ...

Страница 2: ...Use Mounting Screws Provided With The Outlet Box CAUTION For Compliance with Local Codes and Regulations If Installing The Secondary Support Safety Cable in the U S Do Not Re move Knockouts In The Outlet Box Mount the secondary support safety cable through the reserved nail screw hole on the outlet box to the building structure or the ceiling joist WARNING To reduce the risk of personal injury do ...

Страница 3: ...l cause the fan to wobble Use only the screws provided with the outlet box 3 Remove the cotter pin from the downrod and save it for later use 4 Tread leadwires and safety cable first through the canopy disk canopy and last the downrod 5 Canopy disk Downrod Canopy Tighten the 2 Set screws on the Yoke once the downrod is in place Check motor for shipping stabilizers and re move if present Hang assem...

Страница 4: ...side covers from canopy ex posing 4 holes 2 closed holes and 2 open L shape holes 17 18 Lift Canopy allowing the 2 studs to protrude through the canopy 13 Next lift the canopy disk and install knurled nuts as shown Tighten the knurled nuts securely The canopy should adjust for any irregularity in the ceiling or Outlet box 14 Connect black and blue wire from fan to Black or Hot wire from house Conn...

Страница 5: ...rews from hardware pack and in sert 2 one on each side of bracket to match the L slot screw holes in canopy Keep 2 screws for later use Remove the all thread studs from the lower part of the mounting bracket 21 Replace the 3 screws removed and tighten securely Check motor for shipping stabilizers and remove if present 20 Place canopy over fan body align ing holes 19 Connect black and blue wire fro...

Страница 6: ...s to motor using the 8 motor screws provided Tighten screws securely Connect the plug from fan to switch house plug 28 Install switch cap to fan using the 3 screws provided Tighten securely 30 Remove the screws from switch housing and save for use later 29 ...

Страница 7: ...aused when blade levels are unequal Check this level by selecting a point on the ceiling above the tip of one of the blades Measure this distance from blade tip to ceilng Keeping measure within 1 8 rotate the fan until the next blade is positioned for measurement Repeat for each blade If all blade levels are not equal you can adjust blade levels by the following procedure To adjust a blade tip dow...