background image

© 2013 Monte Carlo Fan Company

7/1/2013

4

Hang assembled fan from the mounting bracket in-
stalled to ceiling in previous step.  Make sure the fan
is hanging straight.  Rotate fan until the tab on the
Mounting bracket engages the slot on the Downrod
Ball.  This must be done to prevent the fan body from
rotating when the blades are in motion.

12

Make sure the studs protruding from the

bottom of the Mounting bracket are in-

stalled with threads all the way through

the bracket.  

11

Lift Conopy allowing the 2 studs

to protrude through the canopy.  

15

Next lift the cover ring and install knurled

nuts as shown.  Tighten the knurled nuts

securely.  The canopy should adjust for

any irregularity in the ceiling or Outlet

box.

16

Cover Ring

Make wire connections to power source using wire nuts
provided.  Make sure that no filiments are outside of
the wirenut. After making the wire connections, the
wires should be spread apart with the grounded con-
ductor and the equipment-grounding conductor on one
side of the outlet box and ungrounded conductor on the
other side of the outlet box.  

14

Connect black and blue wire from fan to Black or (Hot)
wire from house.  Connect White wire from Fan to White
(Neutral) wire from house.  Connect Ground leads from
mounting bracket and downrod to Ground lead from
house.  

Refer to Safety Tips section of manual.

13

House

Fan

Blue 

Black

White

Green

Black

White

Ground

Pass leadwires  and safety cable

through the canopy.

17

Remove side covers from canopy ex-

posing  4 holes.  2 closed holes and 2

open “L” shape holes.

18

Flush mount installation

For Canadian installation and for USA fan and light

kit combinations over 35 lbs, in both flush and

downrod modes the safety cable must be installed

into the house structure beams using 3” lag

screws, washers and lock washers provided. Make

sure that when the safety cable is fully extended

the lead wires are longer than the cable and no

stress is placed on the lead wires.

Note

:If Installing The Secondary Support Safety

Cable in the U.S., Do Not Remove Knockouts In

The Outlet Box.  

10

Safety cable installation

Safety Cable

Lag Screw

safety

cable

3” lag

screw

lock

washer

washer

Содержание 3TF24BS

Страница 1: ...to this card and retain as your proof of purchase DATE OF PURCHASE MODEL NUMBER RETAILER NAME RETAILER ADDRESS To register your fixture please visit our website www montecarlofans com 3TF24XX Series...

Страница 2: ...Provided With The Outlet Box CAUTION For Compliance with Local Codes and Regulations If Installing The Secondary Support Safety Cable in the U S Do Not Re move Knockouts In The Outlet Box Mount the se...

Страница 3: ...bs Use metal outlet box suitable for fan support must support 35 lbs Before attaching fan to outlet box ensure the outlet box is securley fas tened by at least two points to a structural ceil ing memb...

Страница 4: ...ding conductor on one side of the outlet box and ungrounded conductor on the other side of the outlet box 14 Connect black and blue wire from fan to Black or Hot wire from house Connect White wire fro...

Страница 5: ...refer to Step 10 Place canopy on top of the fan motor allowing the yoke wires and safety cable to pass through the large hole in the center of the canopy Align the 3 larger holes around the center ho...

Страница 6: ...using Not being at tached can cause motor noise Remove twin adhesive tape from the black capacitor as shown above 30 29 Remove 3 screws and save to install switch housing Install the switch housing us...

Страница 7: ...hen blade levels are unequal Check this level by selecting a point on the ceiling above the tip of one of the blades Measure this distance from blade tip to ceilng Keeping measure within 1 8 rotate th...

Страница 8: ...Mar 2012 New format Jul 2013 Update for CUL regulation...