background image

 1

Before you begin installing the fan, Switch 

power off at Service panel and lock service 

disconnecting  means  to  prevent  power 

from being switched on accidentally.  When 

the  service  disconnecting  means  cannot 

be  locked,  securely  fasten  a  prominent 

warning  device,  such    as  a  tag,  to  the 

service panel.

 2

Before  installing  this  fan  make  sure  the 

outlet  box  is  properly  installed  to  the  house 

structure.    To  reduce  the  risk  of  fire,  electric 

shock,  or  personal  injury,  mount  to  outlet 

box  or  supporting  system  acceptable  for  fan 

support. 

(Mounting must support at least 35 lbs.)

 3

Use  metal  outlet  box  suitable  for  fan  support 

and  use  only  the  screws  provided  with  the 

outlet  box    (must  support  35  lbs).  Before 

attaching fan to outlet box, ensure the outlet 

box is securely fastened by at least two points 

to  a  structural  ceiling  member  (  a  loose  box 

will  cause  the  fan  to  wobble).  Remove  the 

two outlet box screws provided with the box, 

aligning  the  holes  of  the  mounting  bracket 
with the holes of the outlet box. Re-install the 
2 outlet box screws securely.

 4

Remove  2  set  screws  from  yoke. 

Save screws for later use. 

 5

 6 

Remove 6 preassembled screws 

from  top  of  motor  assembly. 

Save screws for later use. 

Safety instructions

Helpful Tools

WARNING

: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE 

THE FOLLOWING: READ AND SAVE THESE INSTRUCTIONS

Installation work and electrical wiring must be done by qualified person(s) in accordance with applicable codes and standards (ANSI/NFPA 

70-1999), including fire-rated construction.

Use this unit only in the manner intended by the manufacturer.  If you have  any questions contact the manufacturer.

After making the wire connections, the wires should be spread apart with the grounded conductor and the equipment-grounding conductor 

on one side of the outlet box and ungrounded conductor on the other side of the outlet box. The splices, after being made, should be 

turned upward and pushed carefully up into the outlet box.

WARNING

:  Before  you  begin  installing  the  fan,  servicing  or  cleaning  unit,  Switch  power  off  at  Service  panel  and  lock  service 

disconnecting  means  to  prevent  power  from  being  switched  on  accidentally.  When  the  service  disconnecting  means  cannot  be  locked, 

securely fasten a prominent warning device, such as a tag, to the service panel.

Be cautious! read all instructions and safety information before installing your new fan. Review the accompanying assembly diagrams.

When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.

Make sure the installation site you choose allows the fan blades to rotate without any obstructions. Allow a minimum clearance of 7 feet 

from the floor to the trailing edge of the blade.

WARNING

: To reduce the risk of fire, electric shock, or personal injury, mount to outlet box marked “acceptable for fan support” and use 

mounting screws provided with the outlet box  (Mounting must support at least 35 lbs.)

WARNING

: To reduce the risk of personal injury, do not bend blade holders during installation to motor, balancing or during cleaning.  Do 

not insert foreign object between rotating blades.

Attach the mounting bracket using only the hardware supplied with the outlet box.

WARNING

: To reduce the risk of fire or electric shock, this fan must be installed with an isolating wall control/switch.

WARNING

:  To  reduce  the  risk  of  fire  or  electric  shock,  this  fan  should  only  be  used  with  fan  speed  control  part  no.  UC7067RC 

manufactured by Rhine Electronic Co., Ltd. 

WARNING

: To reduce the risk of fire or electric shock, do not use this fan with any solid state fan speed control device, or variable speed 

control.

If this unit is to be installed over a tub or shower, it must be marked as appropriate for the application.

Never place a switch where it can be reached from a tub or shower.

The combustion airflow needed for safe operation of fuel-burning equipment may be affected by this unit’s operation. Follow the heating 

equipment manufacturer’s guideline safety standards such as those published by the National Fire Protection Association (NFPA), and the 
American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE) and the local code authorities.

CAUTION

: To Reduce the Risk of Electric Shock, Disconnect the electrical supply circuit to the fan before installing the light kit. 

All set screws must be checked and tightened where necessary before installation. 

1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

11.

12.

13.

14.

15.

16.

17.

18.

Remove keeper pin and cross 

pin  from  yoke,  and  save  for 

later use.

Содержание 3MRR52-D Series

Страница 1: ...liente Si vous avez besoin d aide pour l installation des pi ces de remplacement ou si vous avez des questions concernant notre garantie veuillez contacter notre service apr s vente If you need instal...

Страница 2: ...tally When the service disconnecting means cannot be locked securely fasten a prominent warning device such as a tag to the service panel Be cautious read all instructions and safety information befor...

Страница 3: ...d i n s t e p 4 a n d tighten the set screws evenly once the down rod is in place 15 Insert downrod into the yoke on top of fan body Align the hole in the downrod with the hole in the yoke Insert cros...

Страница 4: ...ole slot with the preassembled screw on mounting bracket and twist clockwise to lock in place Install the screw removed in step 17 Tighten all screws securely 25 Attached canopy bottom cap onto canopy...

Страница 5: ...23A all 12V Attach cover of remote by placing over buttons and snap the battery cover in place 34 35 Place face plate over battery compartment and buttons Place remote over 2 pins on front cover Atta...

Страница 6: ...t dimmers LIGHT ON OFF To turn light on press light button once quickly To turn off press once quickly while light is on FAN SPEED Depress l dot for low speed 2 dots for medium or 3 dots for high To t...

Страница 7: ...that the ridge of the canopy engages the notch in the downrod ball 2 Make sure that canopy mounting bracket or mounting plate are tightened securely to ceiling junction box and junction box is mounte...

Страница 8: ...Jan 2011 Apr 2011 Change blue to black on step 29...