Installation work and electrical wiring must be done by qualified person(s) in accordance with applicable codes ANSI/NFPA 70-1999),
including fire-rated construction.
Use this unit only in the manner intended by the manufacturer. If you have any questions contact the manufacturer.
After making the wire connections, the wires should be spread apart with the grounded conductor and the equipment-grounding con-
ductor on one side of the outlet box and ungrounded conductor on the other side of the outlet box.
Before you begin installing the fan, Switch power off at Service panel and lock service disconnecting means to prevent power from
being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device,
such as a tag, to the service panel.
Be cautious! read all instructions and safety information before installing your new fan. Review the accompanying assembly diagrams.
When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
Make sure the installation site you choose allows the fan blades to rotate without any obstructions. Allow a minimum clearance of 7
feet from the floor to the trailing edge of the blade.
To reduce the risk of fire, electric shock, or personal injury, mount to outlet box or supporting system acceptable for fan support and
use only the screws provided with the outlet box. (Mounting must support at least 35 lbs.)
Do not bend blade holders during installation to motor, balancing or during cleaning. Do not insert foreign object between rotating
blades.
Attach the mounting bracket using only the hardware supplied with the outlet box.
To reduce the risk of fire or electric shock, this fan must be installed with an isolating wall control/switch.
To reduce the risk of fire or electric shock, this fan should only be used with fan speed control part no. UC7067RK manufactured by
Rhine Electronic Co., Ltd. Suitable for use with solid-state speed controls.
The combustion airflow needed for safe operation of fuel-burning equipment may be affected by this unit’s operation. Follow the heat-
ing equipment manufacturer’s guideline safety standards such as those published by the National Fire Protection Association (NFPA),
and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE) and the local code authorities.
Before servicing or cleaning unit, Switch power off at Service panel and lock service disconnecting means to prevent power from being
switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such
as a tag, to the service panel.
Air flow direction: warm weather - switch to left - forward / cool weather - switch to right - reverse
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE
FOLLOWING: READ AND SAVE THESE INSTRUCTIONS
s
aFeTY
T
Ips
TOOls reQuIred
Phillips Screwdriver Wire Cutters Pliers Step Ladder
Before you begin installing the fan, Switch
power off at Service panel and lock service dis-
connecting means to prevent power from being
switched on accidentally. When the service dis-
connecting means cannot be locked, securely
fasten a prominent warning device, such as a
tag, to the service panel.
Before installing this fan make sure the outlet box is
properly installed to the house structure. To reduce
the risk of fire, electric shock, or personal injury,
mount to outlet box or supporting system acceptable
for fan support. (Mounting must support at least 35
lbs.)
2
1
Installation
Use metal outlet box suitable for fan support
and use only the screws provided with the out-
let box (must support 35 lbs). Before attaching
fan to outlet box, ensure the outlet box is
securely fastened by at least two points to a
structural ceiling member ( a loose box will
cause the fan to wobble).
use only the screws
provided with the outlet box.
3
Remove cotter pin from ball, and
save for later use.
4
Place canopy over down rod.
5
6
Place Yoke Cover over down rod.