Before you begin installing the fan, Switch
power off at Service panel and lock
service disconnecting means to prevent
power from being switched on
accidentally. When the service
disconnecting means cannot be locked,
securely fasten a warning device, such
as a tag, to the service panel.
Before installing this fan make sure the
outlet box is properly installed to the
house structure. To reduce the risk of
fire, electric shock, or personal injury,
mount to outlet box or supporting system
acceptable for fan support.
(Mounting must support at least 35 lbs.)
Use metal outlet box suitable for fan
support and use only the screws provided
with the outlet box (must support 35
lbs). Before attaching fan to outlet box,
ensure the outlet box is securely fastened
by at least two points to a structural
ceiling member ( a loose box will cause
the fan to wobble). Remove the two outlet
box screws provided with the box,
aligning the holes of the mounting plate
with the holes of the outlet box. Reinstall
the 2 outlet box screws securely.
Loosen 2 screws across from each other
and remove the other 2 preassembled
screws from mounting plate
(Corresponding to installation step 8).
Save screws for later use.
Set dip switches on the Remote
Transmitter and Remote Receiver to the
same settings. This must be done so the
units will communicate properly. If you
have other fans you can set to control
from one Transmitter by setting
receivers the same as the Transmitter. If
you have more than one fan with remote,
you can set the dip switches to different
positions to have separate control.
Note
: Remote receiver is located on the
top plate of motor assembly as shown in
the graphic of installation step 7.
Hang motor assembly onto the hook on
mounting plate for hands-free wiring and
safety cable installation.
For Canadian installation and for USA fan and
light kit combinations over 35 lbs, in both
flush and downrod modes the safety cable
must be installed into the house structure
beams using 3” lag screws, washers and lock
washers provided. Make sure that when the
safety cable is fully extended the lead wires
are longer than the cable and no stress is
placed on the lead wires.
Note
: If Installing The Secondary Support
Safety Cable in the U.S., Do Not Remove
Knockouts In The Outlet Box.
ON
Dip switches
Hook
Lag
screw Safety
cable
Washer
Lock washer
3
Mounting plate