Cautions and Warnings

Installation work and electrical wiring must be done by qualified person(s) in accordance with applicable codes and standards (ANSI/NFPA 70-1999), 

including fire-rated construction.
Use this unit only in the manner intended by the manufacturer.  If you have  any questions contact the manufacturer.
After making the wire connections, the wires should be spread apart with the grounded conductor and the equipment-grounding conductor on one side 

of the outlet box and ungrounded conductor on the other side of the outlet box. The splices, after being made, should be turned upward and pushed 

carefully up into the outlet box.

WARNING:

 Before you begin installing the fan, servicing or cleaning unit, Switch power off at Service panel and lock service disconnecting means to 

prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning 

device, such as a tag, to the service panel.
Be cautious! Read all instructions and safety information before installing your new fan. Review the accompanying assembly diagrams.
When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
Make sure the installation site you choose allows the fan blades to rotate without any obstructions. Allow a minimum clearance of 7 feet from the floor 

to the trailing edge of the blade.

WARNING:

 To Reduce The Risk Of Fire, Electric Shock, or Personal Injury, Mount To Outlet Box Marked “Acceptable for Fan Support of 15.9 kg (35 lbs) 

or less” And Use Mounting Screws Provided With The Outlet Box.

CAUTION

: For Compliance with Local Codes and Regulations, If Installing The Secondary Support Safety Cable in the U.S., Do Not Remove Knockouts 

In The Outlet Box. Mount the secondary support safety cable through the reserved nail/screw hole on the outlet box to the building structure (or the 

ceiling joist).

WARNING:

 To reduce the risk of personal injury, do not bend blade holders during installation to motor, balancing or during cleaning.  Do not insert 

foreign object between rotating blades.
Attach the mounting bracket using only the hardware supplied with the outlet box.

WARNING:

 To reduce the risk of fire or electric shock, this fan must be installed with an isolating wall control/switch.

WARNING:

 To reduce the risk of fire or electric shock, this fan should only be used with fan speed control part no. 7083R manufactured by Rhine 

Electronic Co., Ltd. 

WARNING:

 To reduce the risk of fire or electric shock, do not use this fan with any other solid state fan speed control device, or variable speed control.

If this unit is to be installed over a tub or shower, it must be marked as appropriate for the application.
Never place a switch where it can be reached from a tub or shower.
The combustion airflow needed for safe operation of fuel-burning equipment may be affected by this unit’s operation. Follow the heating equipment 

manufacturer’s guideline safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for 

Heating, Refrigeration and Air Conditioning Engineers (ASHRAE) and the local code authorities.

CAUTION:

 To Reduce the Risk of Electric Shock, Disconnect the electrical supply circuit to the fan before installing the light kit.

CAUTION:

 The light source is designed for this specific application and can overheat if serviced by untrained personnel. If any servicing is required, the 

product should be returned to an authorized service facility for examination or repair.  
All set screws must be checked and tightened where necessary before installation. 

Tools Required for Assembly (not included): Electrical Tape, Phillips Screwdriver, Pliers, Safety Glasses, Stepladder and Wire Strippers

WARNING:

 TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING

 READ AND SAVE THESE INSTRUCTIONS

Customer Service

800-969-3347

Customer Service Center

7400 Linder Ave.

Skokie, IL 60077

www.montecarlofans.com

2

© 2013 Monte Carlo Fan Company

12/2017

Содержание 3CLYR52 D-V1 Series

Страница 1: ...ER NAME RETAILER ADDRESS Attach sales receipt to this card and retain as your proof of purchase To register your fixture please visit our website www montecarlofans com 3CLYR52 42XXXD V1 Series Fan UL...

Страница 2: ...To reduce the risk of personal injury do not bend blade holders during installation to motor balancing or during cleaning Do not insert foreign object between rotating blades Attach the mounting brac...

Страница 3: ...ss from each other and remove the other 2 preassembled screws from mounting plate Corresponding to installation step 8 Save screws for later use Set dip switches on the Remote Transmitter and Remote R...

Страница 4: ...crews securely Loosen 2 screws across from each other and remove the other 2 preassembled screws from side of mounting plate corresponding to installation step 10 Save screws for later use Attach hous...

Страница 5: ...ver over battery compartment and buttons Place remote over 2 pins on front cover Attach cover of remote by placing over 4 pins and snapping into place Install wall control unit to outlet box using mac...

Страница 6: ...ff FORWARD REVERSE Depress reverse button with fan running Allow a few seconds for fan to slow down and change rotation direction Clicking noise may be heard after depressing button Note If not using...

Страница 7: ...LQ SHULRG RI KRXUV 0RVW QRLVHV DVVRFLDWHG ZLWK D QHZ IDQ ZLOO GLVDSSHDU DIWHU WKLV SHULRG I WKLV LV D GRZQURG PRXQW IDQ PDNH VXUH WKH ULGJH RQ PRXQWLQJ EUDFNHW HQJDJHV WKH QRWFK LQ WKH GRZQURG EDOO 0D...

Страница 8: ...Mar 2018 V1 edition...

Отзывы: