7
INSTALLATION
Final Assembly
1. Reinstall the grid frame and top grids and check for proper operation of the grid adjustment
lever. Check to be certain that all tie wires have been removed from the burners and that the
reflectors and radiants are properly positioned between their alignment notches. Replace the
drip tray grease container, debris screen, and heat shields.
Gas Settings
PILOT LIGHTING INSTRUCTIONS:
1. Remove debris screen and light each pilot with matches or taper from underneath. Replace
screen.
2. Set pilot valve with screwdriver to provide 1/2‖ flame by turning counterclockwise.
3. Turn desired burner valve on.
4. To shutdown, turn pilot valve clockwise until tight.
5. Do not attempt to relight for 5 minutes after shutdown.
The burner flame should be 1-1/2‖ to 2‖ high on natural gas and approximately 3/4‖ to 1‖ on pro-
pane gas. Turn the gas valve on and off several times and observe the flames on the burners. If
they are yellow and soft, open the air shutter slightly or until yellow disappears. If flames seem
to blow or lift form burner ports, close the air shutter until this does not occur. Secure air shutter
after burner has been adjusted.