5
The gas pressure regulator furnished by the installer must comply with the following:
1. The pressure regulator(s) must have a maximum regulation capacity for the total connected
load.
2. The pressure regulator(s) installed must be listed by a nationally recognized testing agency.
3. The pressure regulator(s) must have a pressure adjustment range to allow adjustment to the
manifold pressure on the appliance rating plate.
4. Unless the manifold pressure on all connected appliances is the same, a separate pressure
regulator must be supplied for each appliance(s) having differing manifold pressures.
GAS CONNECTION
Before connecting the range battery to the gas supply line, be sure that all new piping has been
cleaned and purged to prevent any foreign matter from being carried into the controls by the gas.
In some cases, filters or drops are recommend. A separate Gas Shut off Valve must be installed
upstream from the gas pressure regulator adjacent to the range battery and located in an accessible
area.
WARNING:
CAP ALL UNUSED OPEN ENDS OF THE GAS SUPPLY MANIFOLD.
It is important that adequately sized piping be run directly to the point of connection at range
battery with as few elbows and tees as possible. Consult local gas company for proper piping size
and gas pressure.
PIPE JOINT COMPOUND OR THREAD SEALANT THAT IS USED SHOULD BE
RESISTANT TO ACTION OF LIQUEFIED PETROLEUM GASES.
Turn Gas Shut Off Valve "ON" and immediately check carefully for gas leaks. Do this before
attempting to operate the range battery.
SERVICE