17
SERVICE
THERMOSTAT INSTALLATION
With front of the griddle plate raised, slide the thermostat bulb assembly into the support
brackets attached to the underside of the Fry Top plate. Tighten the two holding screws. The ex-
cess capillary tube should be pulled forward out of the heat zone so that there is no chance of it
coming in contact with the burner flame. Push the sleeving up against the bulb holder. A loose fit
between the bulb holder and plate may damage the thermostat so that it will not control the tem-
perature of the Fry Top plate accurately.
ADJUSTMENT OF BYPASS (MINIMUM BURNER) FLAME
This is the flame which must be maintained on the burners when the Fry Top has reached
the temperature set on the dial. Enough gas must be bypassed by the control to keep the entire
burner lit. The thermostat regulates the flame from high to low in accordance with the Fry Top
temperature and will automatically turn down to this bypass flame when the temperature set on
the dial is attained.
Special care should be taken to see that the thermostat bulb is in its proper place and no
part of the capillary tube is in any flame or heat zone. The Fry Top plate should never be removed
without first removing the thermostat bulb(s) from beneath the plate. Never allow capillary tube to
be kinked or crushed.