8
1 ~ 16 and Scene MIDI Channel. If this is set to Scene MIDI Channel, messages will be
sent on the same MIDI channel as that of the Scene.
Trigger Pads
Depending on the assign type, the Trigger Pads can transmit Note messages or Control
Change messages. For each Trigger Pad, you can individually specify the assigned message,
the MIDI transmit channel, the behavior of the trigger pad, the note number, the control
change number, and the values transmitted when the pad turns on or off.
Depending on its assign type, a Note number or Control Change number can be assigned
to a single Trigger Pad. If you transmit Note messages or Control Change messages from a
trigger pad, all of the messages will be transmitted at the velocity or On Value/Off Value.
•
MIDI Channel: This specifies the MIDI channel of the MIDI messages that are
transmitted when you strike the Trigger Pad. If you set this to Global MIDI Channel,
the messages will be transmitted on the Global MIDI channel. The possible values
are 1-16 and Global MIDI Channel.
•
Assign Type: This specifies the type of message that will be assigned to the Trigger
Pad. You can disable the pad (No Assign), or assign a Note message or a Control
Change message. The possible values are No Assign, Note, or Control Change.
•
Pad Behavior: You can choose one of two types of behavior for each Trigger Pad,
Momentary or Toggle. If set to Momentary, the Note On or On Value will be
transmitted when you press the Pad and the Note Off or Off Value will be
transmitted when it is released. If set to Toggle, the Note On or On Value will be
transmitted the first time you press the Pad and the Note Off or Off Value will be
transmitted the next time you press the Pad.
•
Note Number: This specifies the number of the Note message that is transmitted.
The possible values are C1 ~ G9 and No Assign.
•
CC Number: This specifies the number of the Control Change message that is
transmitted. The possible values are 0 ~ 127 and No Assign.
•
On Value: This specifies the value of the message that is transmitted when the
Trigger Pad turns on. The range of values is 0 ~ 127.