 INFORMATIONS FOR THE USER 

 

SPECIFICATIONS

 

POWER SUPPLY 

Alkaline batteries (4x1,5V AA) 

MINIMUM WORKING PRESSURE 

0,5 bar 

MAXIMUM WORKING PRESSURE 

4 bar 

MAXIMUM  WORKING TEMPERATURE 

70°C 

MINIMUM SENSING DISTANCE 

0,5cm 

MAXIMUM  SENSING DISTANCE 

15 cm 

FLOW RANGE 

5 l/min with 3 bar pressure 

FLEXIBLES CONNECTION  

G 1/2" F 

FLEXIBLES LENGHT 

35 cm 

WARNING LOW BATTERY 

yes 

VANDAL PROOF SYSTEM 

yes 

ANTI-LEGIONELLA SYSTEM 

yes 

 

ASSEMBLY INSTRUCTIONS: 

 

In case of new plumbing , always proceed to drain the pipes before 
installation. 

 

1.  Turn off the water supplies. 

2.  Screw the stay bolt 

(H)

 to the mixer tap 

(G)

. Insert the base 

(I)

, the O-Ring 

(J)

 

and screw the flexibles 

(B)

 to the mixer tap 

(G)

3.    Place  the  tap  on  the  sink  by  passing  the  flexibles 

(B)

  and  the  sensor  cables 

(C1,C2) 

in the sink hole, staring it with the fixing kit. 

4.  Screw the swinging spout 

(F)

 to the tap 

(G)

5.  Connect the solenoid valves 

(D)

 to the flexibles  

(B)

 according to the input of the 

water (see pic. 1). 

6.    Connect  the  connectors 

(K)

  to  the  solenoid valves 

(D)

,  paying  attention  to  the 

polarity of the cables (see pic. 1). 

7.    Secure  the  battery  holder 

(E)

  on  the  wall  under  the  sink,  using  the  velcro  and 

making sure that the cable outlet is facing downward. (see pic. 2) 

8.  Insert the 4 alkaline batteries in the battery holder 

(E)

. Pay attention to the poles 

+ and -. 

9.  Conect the cable 

(C1)

 to the battery holder 

(E)

.

 

 
 
 
 

 
 
 

FUNCTIONING: 

 

The infrared sensor 

(A)

 identifies the presence of the hands and the valve begins to 

provide the water till the sensor  will no more detect the hands in front of the sensor 

or until the expiration of the maximum time of closing (VANDAL PROOF SYSTEM). 

If the infrared system detects an object for 5 minutes, the system cut off  the water 

supply  until  the  object  will  not  be  removed. 

Once  the  foreign  object  has  been 

removed, the tap will resume regular operation.

 

The low battery is indicated by flashing red LED light with increasing speed. 

The solenoid valve closes and the system hangs waiting for the battery replacements. 

After 24 hours of non-use, the tap is automatically activated to prevent the 

LEGIONELLA bacterium (ANTI-LEGIONELLA SYSTEM). 

Failure  to  supply  water,  check  that  the  batteries  are  charged  and/or  correctly 

positioned. 

The operation of the tap is guaranteed only with water free of impurities, therefore it 
is

 important install the faucet filters.

 

FAILURE IN FOLLOW THE INFORMATIONS CONTAINED IN THIS LEAFLET 

WILL INVALIDATE THE WARRANTY 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

 