Save time and money! Review the charts on the following pages first and you may not need to call for service.
Problem
Possible Causes
What To Do
Fan does not operate when the On/
2ႇEXWWRQLVSXVKHG
A fuse may be blown or a circuit breaker
tripped.
Replace fuse or reset circuit breaker.
)DQNHHSVJRLQJRႇDQGRQ
The motor is probably overheating and
WXUQLQJLWVHOIRႇ7KLVFDQEHKDUPIXOWR
the motor.
&KHFNWREHVXUHWKH¿OWHULVFOHDQ,IRႇDQG
on cycling continues, call for service. Visit
Monogram.com
for available makeup air
solutions.
)DQ¿OWHUOLJKWLVRQ
After 30 hours of “on” or running time,
the light reminds you to clean the metal
JUHDVH¿OWHUV
7KHOLJKWZLOOJORZXQWLOWKH¿OWHUVDUHUHSODFHG
7KHULJKWVLGH¿OWHULVQRWPDNLQJFRQWDFW
with the switch.
$GMXVWWKH¿OWHULQSODFH
Fan does not operate when fan On/
2ႇEXWWRQLVSUHVVHGRUZKHQRU±
button is pressed
The blower connector is loose or not
plugged into its mating connector.
Disconnect power to the unit. Lift the lower duct
cover and look at the blower connector plug.
If the blower connector plug is loose, plug it in
securely. See the Installation Instructions for the
plug location and how to plug in the connector.
/RXGRUDEQRUPDODLUÀRZQRLVH
Wrong size duct used in installation.
This hood requires 6” ducting and a maximum
duct length of 100 equivalent feet to perform
optimally. Using smaller duct pipe or longer
equivalent lengths of duct pipe will cause
improper venting. Monogram service
technicians cannot correct this issue if installed
improperly.
Fan fails to circulate air or moves
air slower than normal and/or fan is
PDNLQJORXGRUDEQRUPDODLUÀRZQRLVH
Obstructions in duct work.
Make sure nothing is blocking the vent. Make
sure your wall or roof cap has a blade or door.
Damper blade on wall or roof cap may
not be open.
Make sure damper swings freely. Damper blades
PD\ÀLSRYHUDQGZLOOQRWIXOO\RSHQZKHQWKLV
happens. Adjust to original position.
0HWDOJUHDVH¿OWHUDQGFKDUFRDO¿OWHULI
present) may be dirty.
&OHDQWKHPHWDOJUHDVH¿OWHUDQGUHSODFH
FKDUFRDO¿OWHULISUHVHQW6HH&DUHDQG
Cleaning.
6XႈFLHQWPDNHXSUHSODFHPHQWDLULV
required for exhausting appliances to
operate to rating.
Check with local building codes, which may
require or strongly advise the use of makeup
air.
The hood controls are not operating
correctly
Control logic confused.
Disconnect power to the hood by resetting
the circuit breaker. Wait 30 seconds to allow
controls to reset.
Early bulb failure
Replacing bulbs with bare hands.
Replace bulbs while wearing gloves to keep skin
RLOVRႇEXOEV
Bulb wattage is too high.
Replace with correct wattage.
TROUBLESHOOTING
Содержание ZV750
Страница 1: ...OWNER S MANUAL Stainless Steel Vent Hood MONOGRAM COM ENGLISH FRANÇAIS ESPAÑOL ...
Страница 10: ...10 49 80569 Rev 4 NOTES ...
Страница 12: ...12 49 80569 Rev 4 49 80569 Rev 4 10 19 GEA Printed in Italy ...
Страница 13: ...MANUEL D UTILISATION Hotte aspirante en acier inoxydable FRANÇAIS MONOGRAM COM ...
Страница 22: ...10 49 80569 Rev 4 NOTES ...
Страница 24: ...12 49 80569 Rev 4 49 80569 Rev 4 10 19 GEA Imprimé en Italie ...
Страница 25: ...MANUAL DEL PROPIETARIO Campana de ventilación de acero inoxidable ESPAÑOL MONOGRAM COM ...
Страница 34: ...10 49 80569 3 NOTAS ...
Страница 36: ...12 49 80569 3 49 80569 Rev 4 10 18 GEA Impreso en Italia ...