Design Guide - Flush Installation
23
38-3/4" Frame to
Frame Width
*84" From
Floor to
Top Frame
35"
Case Width
*83-1/2"
at
Rear
25-3/8" Case Depth
Depth Including
Handles 26-7/8"
THE INSTALLATION SPACE
Water And Electrical Locations
Electrical and water supply must be located as shown.
Cutout Depth Beneath a Soffit:
When installed beneathh a soffit, the soffit cannot
exceed the 26-3/16” installation depth shown.
The Cutout Depth Must Be 26-3/16”
Wooden cleats are required for flush installation. See
Side Cleats on page 29.
Additional Specifications
• A 115 volt 60Hz., 15 or 20 amp power supply is
required. An individual properly grounded branch
circuit or circuit breaker is recommended. Install
a properly grounded 3-prong electrical receptacle
recessed into the back wall. Electrical must be located
on rear wall as shown.
NOTE: GFI (ground fault interrupter) is not
recommended.
• Water line can enter the opening through the floor or
back wall. The water line should be 1/4” O.D. copper
tubing or QuickConnect
™
kit between the cold water
line and water connection location, long enough to
extend to the front of the unit. Installation of an easily
accessible shut-off valve in the water line is required.
DIMENSIONS AND CLEARANCES
Product Clearances
These units are equipped with a 3-position door stop.
The factory set 115° door swing can be adjusted to 90°
if clearance to adjacent cabinets or walls is restricted.
90° Door Swing
90° Door Swing
4” Minimum
to a Wall
90°
23-7/8”
Case Behind
Frame
38-3/4”
39”
Finished Width
Wall View
Electrical
Area
26-3/16” Minimum
Cutout Depth
Cold Water
Suppl
y
75-1/2” From
Floor to Bottom
of Electrical Area
85”
Finished
Opening
4-5/16”
3-1/2”
3-1/2”
3-1/2”
3-1/2”
3-1/2”
5-1/2”
9”
7”
7”
For a 90° door swing, allow 4” minimum clearance to
a wall for framed and stainless steel models. If the 90°
doorstop position is used, pan access is maintained but
pan removal is restricted.
115° Door Swing
* Shipping height. The
product can be adjusted
to fit into a cutout that
is 85” max. height. Use
leveling legs and wheels
for a maximum 1” height
adjustment.
Содержание ZIFS360NHLH
Страница 1: ...Installation Instructions 36 Built In All Refrigerators and All Freezers monogram com...
Страница 5: ...Instructions for Standard Installation 5...
Страница 22: ...Instructions for Flush Installation 22...
Страница 38: ...Instructions for Stainless Steel Installation 38...
Страница 50: ...50 Notes...
Страница 51: ...51 Notes...