36" Frame to
Frame Width
*84" From
Floor to
Top Frame
35"
Case Width
*83-1/2"
at
Rear
25-3/8"
Framed Models
Depth Including Handles 26-7/8"
THE INSTALLATION SPACE
Water And Electrical Locations
Electrical and water supply must be located as shown.
The Cutout Depth Must Be 26-3/16”
Wooden cleats are required for flush installation. See Side
Cleats on page 27.
Cutout depth beneath a soffit:
When installed beneath a soffit, the soffit cannot exceed
the 26-3/16
”
installation depth shown. The top case trim
overlaps the bottom of the soffit.
Additional Specifications
• A 115 volt 60Hz., 15 or 20 amp power supply is required.
An individual properly grounded branch circuit or circuit
breaker is recommended. Install a properly grounded
3-prong electrical receptacle recessed into the back wall.
Electrical must be located on rear wall as shown.
NOTE: GFI (ground fault interrupter) is not recommended.
• Water line can enter the opening through the floor or back
wall. Route GE SmartConnect
™
kit or 1/4
”
O.D. copper tubing
between the cold water line and the water connection
location. The tubing should be long enough to extend to the
front of the refrigerator. Installation of an easily accessible
shut-off valve in the water line is required.
DIMENSIONS AND CLEARANCES
* Shipping height. The
refrigerator can be
adjusted to fit into a
cutout that is 85
”
max.
height. Use leveling
legs and wheels for a
maximum 1
”
height
adjustment.
Product Clearances
These refrigerators are equipped with a 3-position door
stop. The factory set 115° door swing can be adjusted to
90° if clearance to adjacent cabinets or walls is restricted.
21
*Min. Distance to Wall: 4"
38-3/4"
90°
90° Door Swing
20-5/8"
Behind
Frame
6"
Wall View
Electrical
Area
85"
Finished
Opening
75-1/2" From
Floor to Bottom
of Electrical Area
10"
26-3/16" Cutout
Depth
39"
Finished Width
4-5/16"
7"
3-1/2"
3-1/2"
3-1/2"
3-1/2"
7"
3-1/2"
Water Supply
For a 90 degree door swing, allow 4” min. clearance to
wall. If the 90 degree door stop position is used, pan
access is maintained, but pan removal is restricted
Design Guide - Flush Installation
115° Door Swing
CUSTOM HANDLE DESIGN GUIDE
Custom handles must be used for flush installation. For
custom handle installation, counterbore holes in rear of
decorative panels must ensure 1/2” material thickness
remains for handle support.
NOTE: The counterbore must not exceed 1” in diameter.
Minimum distance on Fresh Food
Door from handle side edge to
handle center should be 2-1/2”
as shown.
Minimum distance on Freezer
Door from top edge to handle
center on the freezer drawer
should be 1-1/2” as shown.
1/4”
1/2”
3/4”
7/8"
0.85"
1/2"
2-1/2”
1-1/2”
Содержание ZICS360NHRH
Страница 5: ...Instructions for Standard Installation 5...
Страница 20: ...Instructions for Flush Installation 20...
Страница 36: ...Instructions for Stainless Steel Installation 36...
Страница 47: ...47 Notes...