Performance Data Sheet

SmartWater

 Filtration System

GE MWF Cartridge 

The concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible 

limit for water leaving the system as specified in NSF/ANSI Standard 42 and Standard 53. System tested and certified by NSF International against 

NSF/ANSI Standard 42 and Standard 53 for the reduction of substances listed below. 

The following pharmaceutical reduction claims have not been certi

ed by NSF International or the state of California.  

Claims tested and veri

ed by independent laboratory:

Contaminant  

Reduction

Av

erage Influent

NSF specified

 

 Challenge Concentration

Avg %  

Reduction

Average Product 

Water  

Concentration

Max Permissible  

Product Water  

Concentration

NSF Reduction 

Requirements

NSF  

Test Report

Atenolol

978 ng/L

N/A

99.5%

5.0 ng/L

N/A

N/A

J-00121587

Fluoxetine

907 ng/l

N/A

99.4%

5.4 ng/L

N/A

N/A

J-00121587

Ibuprofen

885 ng/L

N/A

94.1%

52.3 ng/L

N/A

N/A

J-00121588

Progesterone

1097 ng/L

N/A

99.5%

5.0 ng/L

N/A

N/A

J-00121589

Trimethoprim

415 ng/L

N/A

99.5%

2.0 ng/L

N/A

N/A

J-00121587

It is essential that the manufacturer’s recommended installation, maintenance and filter replacement requirements be carried out for the product to perform as advertised.  

See Installation Manual for Warranty information.

Application Guidelines/Water Supply Parameters

Service Flow

0.5 gpm  (21.9 lpm)

Water Supply

Potable Water

Water Pressure

40-120 psi (2.8-8.2 bar)

Water Temperature

33°F-100°F (0.6°C-38°C)

Note: 

While the testing was performed under standard laboratory conditions, 

actual performance may vary. 

Replacement Cartridge: MWF. For estimated costs of replacement elements  

please call 1-800-626-2002 or visit our website at www.geapplianceparts.com.

       WARNING

To reduce the risk associated with ingestion of contaminants:

•  Do not use with water that is microbiologically unsafe or of unknown quality 

without adequate disinfection before and after the system. Systems cert

ifi

ed 

for cyst reduction may be used on disinfected water that may contain 

lterable 

cysts. EPA Establishment Number 10350-MN-005.

NOTICE

To reduce the risk associated with property damage due to water leakage:

• Read and follow use instructions before installation and use of this system.

• Installation and use MUST comply with all state and local plumbing codes.

•  Do not install if water pressure exceeds 120 psi (8.2 bar). If your water pressure 

exceeds 80 psi, you must install a pressure-limiting valve. Contact a plumbing 

professional if you are uncertain how to check your water pressure. 

•  Do not install where water hammer conditions may occur. If water hammer 

conditions exist you must install a water hammer arrester. Contact a plumbing 

professional if you are uncertain how to check for this condition.

•  Do not install on hot water supply lines. The maximum operating water 

temperature of this 

lter system is 100º F (38º C).

•  Protect 

lter from freezing. Drain 

lter when temperatures drop  

below 33ºF (0.6ºC).

•  

must be replaced every 6 months at the  

rated capacity, or sooner if a noticeable reduction in 

flo

w rate occurs.

For conditions of use, health claims certified by the California Department of Public 

Health, and replacements, see performance data sheet. California Department 

of Public Health Certification #05-1698. The contaminants or other substances 

removed or reduced by this water filter are not necessarily in all users’ water.

Capacity 300 Gallons (1,135 Liters).   Contaminant Reduction Determined by NSF testing.

Substance Tested  

for Reduction

Av

erage Influent

NSF specified

 

 Challenge Concentration

Avg %  

Reduction

Average Product 

Water  

Concentration

Max Permissible 

Product Water 

Concentration

NSF Reduction 

Requirements

NSF  

Test Report

Chlorine Taste and Odor

2.0 mg/L

2.0 mg/L ± 10%

97.5%

0.05 mg/L

N/A

≥ 50%

J-00077703

Nominal Particulate 

Class I, , ≥0.5 to < 1.0 µm

7,833,333 pts/mL At least 10,000 particles/mL

99.7%

18,617 pts/mL

N/A

≥85%

J-00077704

Cyst*

101,000 cysts/L

Minimum 50,000 cysts/L

99.99%

1 cyst/L

N/A

≥99.95%

J-00100036

Asbestos

47 MF/L

107 to 108 fibe

r

s/L; fibe

rs       

gr

eater than 10 µm in length

>99%

<1 MF/L

N/A

≥99%

J-00077707

Atrazine

0.009 mg/L

0.009 mg/L ± 10%

94.5%

0.0005 mg/L

0.003 mg/L

N/A

J-00077708

Benzene

0.016 mg/L

0.015 mg/L ± 10%±

96.7%

0.0005 mg/L

0.005 mg/L

N/A

J-00077717

Carbofuran

0.08 mg/L

0.08 mg/L ± 10%

98.7%

0.001 mg/L

0.04 mg/L

N/A

J-00077718

Endrin

0.007 mg/L

0.006 mg/L ± 10%

97.1%

0.0002 mg/L 

0.002 mg/L

N/A

J-00100039

Lead @ pH 6.5

0.152 mg/L

0.15 mg/L ± 10%

99.3%

0.001 mg/L

0.010 mg/L

N/A

J-00077722

Lead @ pH 8.5

0.148 mg/L

0.15 mg/L ± 10%

99.3%

0.001 mg/L

0.010 mg/L

N/A

J-00077723

Lindane

0.002 mg/L

0.002 mg/L ± 10%

99.0%

0.00002 mg/L

0.0002 mg/L 

N/A

J-00077726

Mercury @ pH 6.5

0.0058 mg/L

0.006 mg/L ± 10%

93.2%

0.0004 mg/L

0.002 mg/L

N/A

J-00100037

Mercury @ pH 8.5

0.0061 mg/L

0.006 mg/L ± 10%

93.2%

0.0004 mg/L

0.002 mg/L

N/A

J-00092355

P-Dichlorobenzene

0.222 mg/L

0.225 mg/L ± 10%

99.8%

0.005 mg/L

0.075 mg/L

N/A

J-00077729

Tetrachloroethylene

0.015 mg/L

0.015 mg/L ± 10%

96.7%

0.0005 mg/L

0.005 mg/L

N/A

J-00082184

Toxaphene

0.015 mg/L

0.015 mg/L ± 10%

93.2%

0.001 mg/L

0.003 mg/L

N/A

J-00077730

2,4-D

0.218 mg/L

0.210 mg/L ± 10%

99.5%

0.0009 mg/L

0.07 mg/L

N/A

J-00085470

*Based on the use of Cryptosporidium parvum oocysts.

Tested and cer

tifi

ed by NSF International 

against NSF/ANSI Standard 42 and  

Standard 53 in model GE MWF for the 

reduction of the claims speci

fie

d on the 

performance data sheet.

REPLACEMENT 

 ELEMENT

National Sanitation 

Foundation

Performance Data Sheet

SmartWater

 Filtration System

GE MWF Cartridge 

The concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible 

limit for water leaving the system as specified in NSF/ANSI Standard 42 and Standard 53. System tested and certified by NSF International against 

NSF/ANSI Standard 42 and Standard 53 for the reduction of substances listed below. 

The following pharmaceutical reduction claims have not been certi

ed by NSF International or the state of California.  

Claims tested and veri

ed by independent laboratory:

Contaminant  

Reduction

Av

erage Influent

NSF specified

 

 Challenge Concentration

Avg %  

Reduction

Average Product 

Water  

Concentration

Max Permissible  

Product Water  

Concentration

NSF Reduction 

Requirements

NSF  

Test Report

Atenolol

978 ng/L

N/A

99.5%

5.0 ng/L

N/A

N/A

J-00121587

Fluoxetine

907 ng/l

N/A

99.4%

5.4 ng/L

N/A

N/A

J-00121587

Ibuprofen

885 ng/L

N/A

94.1%

52.3 ng/L

N/A

N/A

J-00121588

Progesterone

1097 ng/L

N/A

99.5%

5.0 ng/L

N/A

N/A

J-00121589

Trimethoprim

415 ng/L

N/A

99.5%

2.0 ng/L

N/A

N/A

J-00121587

It is essential that the manufacturer’s recommended installation, maintenance and filter replacement requirements be carried out for the product to perform as advertised.  

See Installation Manual for Warranty information.

Application Guidelines/Water Supply Parameters

Service Flow

0.5 gpm  (21.9 lpm)

Water Supply

Potable Water

Water Pressure

40-120 psi (2.8-8.2 bar)

Water Temperature

33°F-100°F (0.6°C-38°C)

Note: 

While the testing was performed under standard laboratory conditions, 

actual performance may vary. 

Replacement Cartridge: MWF. For estimated costs of replacement elements  

please call 1-800-626-2002 or visit our website at www.geapplianceparts.com.

       WARNING

To reduce the risk associated with ingestion of contaminants:

•  Do not use with water that is microbiologically unsafe or of unknown quality 

without adequate disinfection before and after the system. Systems cert

ifi

ed 

for cyst reduction may be used on disinfected water that may contain 

lterable 

cysts. EPA Establishment Number 10350-MN-005.

NOTICE

To reduce the risk associated with property damage due to water leakage:

• Read and follow use instructions before installation and use of this system.

• Installation and use MUST comply with all state and local plumbing codes.

•  Do not install if water pressure exceeds 120 psi (8.2 bar). If your water pressure 

exceeds 80 psi, you must install a pressure-limiting valve. Contact a plumbing 

professional if you are uncertain how to check your water pressure. 

•  Do not install where water hammer conditions may occur. If water hammer 

conditions exist you must install a water hammer arrester. Contact a plumbing 

professional if you are uncertain how to check for this condition.

•  Do not install on hot water supply lines. The maximum operating water 

temperature of this 

lter system is 100º F (38º C).

•  Protect 

lter from freezing. Drain 

lter when temperatures drop  

below 33ºF (0.6ºC).

•  

must be replaced every 6 months at the  

rated capacity, or sooner if a noticeable reduction in 

flo

w rate occurs.

For conditions of use, health claims certified by the California Department of Public 

Health, and replacements, see performance data sheet. California Department 

of Public Health Certification #05-1698. The contaminants or other substances 

removed or reduced by this water filter are not necessarily in all users’ water.

Capacity 300 Gallons (1,135 Liters).   Contaminant Reduction Determined by NSF testing.

Substance Tested  

for Reduction

Av

erage Influent

NSF specified

 

 Challenge Concentration

Avg %  

Reduction

Average Product 

Water  

Concentration

Max Permissible 

Product Water 

Concentration

NSF Reduction 

Requirements

NSF  

Test Report

Chlorine Taste and Odor

2.0 mg/L

2.0 mg/L ± 10%

97.5%

0.05 mg/L

N/A

≥ 50%

J-00077703

Nominal Particulate 

Class I, , ≥0.5 to < 1.0 µm

7,833,333 pts/mL At least 10,000 particles/mL

99.7%

18,617 pts/mL

N/A

≥85%

J-00077704

Cyst*

101,000 cysts/L

Minimum 50,000 cysts/L

99.99%

1 cyst/L

N/A

≥99.95%

J-00100036

Asbestos

47 MF/L

107 to 108 fibe

r

s/L; fibe

rs       

gr

eater than 10 µm in length

>99%

<1 MF/L

N/A

≥99%

J-00077707

Atrazine

0.009 mg/L

0.009 mg/L ± 10%

94.5%

0.0005 mg/L

0.003 mg/L

N/A

J-00077708

Benzene

0.016 mg/L

0.015 mg/L ± 10%±

96.7%

0.0005 mg/L

0.005 mg/L

N/A

J-00077717

Carbofuran

0.08 mg/L

0.08 mg/L ± 10%

98.7%

0.001 mg/L

0.04 mg/L

N/A

J-00077718

Endrin

0.007 mg/L

0.006 mg/L ± 10%

97.1%

0.0002 mg/L 

0.002 mg/L

N/A

J-00100039

Lead @ pH 6.5

0.152 mg/L

0.15 mg/L ± 10%

99.3%

0.001 mg/L

0.010 mg/L

N/A

J-00077722

Lead @ pH 8.5

0.148 mg/L

0.15 mg/L ± 10%

99.3%

0.001 mg/L

0.010 mg/L

N/A

J-00077723

Lindane

0.002 mg/L

0.002 mg/L ± 10%

99.0%

0.00002 mg/L

0.0002 mg/L 

N/A

J-00077726

Mercury @ pH 6.5

0.0058 mg/L

0.006 mg/L ± 10%

93.2%

0.0004 mg/L

0.002 mg/L

N/A

J-00100037

Mercury @ pH 8.5

0.0061 mg/L

0.006 mg/L ± 10%

93.2%

0.0004 mg/L

0.002 mg/L

N/A

J-00092355

P-Dichlorobenzene

0.222 mg/L

0.225 mg/L ± 10%

99.8%

0.005 mg/L

0.075 mg/L

N/A

J-00077729

Tetrachloroethylene

0.015 mg/L

0.015 mg/L ± 10%

96.7%

0.0005 mg/L

0.005 mg/L

N/A

J-00082184

Toxaphene

0.015 mg/L

0.015 mg/L ± 10%

93.2%

0.001 mg/L

0.003 mg/L

N/A

J-00077730

2,4-D

0.218 mg/L

0.210 mg/L ± 10%

99.5%

0.0009 mg/L

0.07 mg/L

N/A

J-00085470

*Based on the use of Cryptosporidium parvum oocysts.

Tested and cer

tifi

ed by NSF International 

against NSF/ANSI Standard 42 and  

Standard 53 in model GE MWF for the 

reduction of the claims speci

fie

d on the 

performance data sheet.

REPLACEMENT 

 ELEMENT

National Sanitation 

Foundation

Performance Data Information

Capacity: 300 Gallons (1,135 Liters)

The concentration of the contaminants tested for this filter in water entering the system was reduced to 

a concentration less than or equal to the permissible limit for water leaving the system as specified in 

NSF/ANSI Standard 42 and Standard 53.  System tested and certified by NSF International against NSF/

ANSI Standard 42 and Standard 53. 

Please see geappliances.com for complete listing of the contaminants  tested and the amounts reduced

Содержание ZIC360NHLH

Страница 1: ...Owner s Manual Bottom Freezer Built In Refrigerators 09 14 GE monogram com 224D3094P002 49 60721 2...

Страница 2: ...Serial Numbers 3 Performance Data Sheet 17 Problem Solver 15 16 Product Registration 3 Safety Instructions 4 7 Warranty Back Cover Care and Cleaning Cleaning Outside and Inside 13 Light Bulb Replacem...

Страница 3: ...age in the back of this manual We re proud of our service and want you to be pleased If for some reason you are not happy with the service you receive here are steps to follow for further help For cus...

Страница 4: ...nces between the doors and between the doors and cabinet are necessarily small Be careful closing doors when children are in the area Do not touch the cold surfaces in the freezer compartment when han...

Страница 5: ...ns avec mise la terre pour appareil lectrom nager et doit tre quip d une fiche et d une prise femelle avec terre Les caract ristiques lectriques du cordon prolongateur doivent tre de 15 amp res minimu...

Страница 6: ...ts which could cause a fire hazard from overheated wires Never unplug your refrigerator by pulling on the power cord Always grip plug firmly and pull straight out from the outlet Repair or replace imm...

Страница 7: ...0 Hz avec un fusible de 15 ou 20 amp res et une mise la terre est n cessaire Ceci permet d obtenir un meilleur rendement et vite de surcharger les circuits lectriques du domicile qui risque d occasion...

Страница 8: ...ess the or pad once After 5 seconds the display will return to the actual temperature To change the temperature settings press the or pads to desired temperature set point for fresh food and freezer s...

Страница 9: ...to the holder 3 Slowly turn it to the right until the filter cartridge stops DO NOT OVERTIGHTEN As you turn the cartridge it will automatically raise itself into position The cartridge will move about...

Страница 10: ...ilable at extra cost The Sabbath Mode Product Kit was designed for use on the Jewish Sabbath and Holidays The Sabbath Mode feature makes it possible for observant Jews to refrigerate and freezer food...

Страница 11: ...humidity levels recommended for most leafy vegetables Slide the control all the way to the Low setting and the drawer provides lower humidity levels recommended for most fruits Excess water that may...

Страница 12: ...ercles en verre avec de l eau ti de quand ceux ci sont froids Les clayettes et couvercles en verre peuvent se casser s ils sont expos s des changements soudains de temp rature ou si vous les cognez ou...

Страница 13: ...ppliance wax or polish on the stainless steel Cleaning inside To help prevent odors leave an open box of baking soda in the refrigerator and freezer compartments Turn off power at the circuit breaker...

Страница 14: ...pull the shield toward you and swing the back of the shield down 3 Replace with the same size bulb 40 watt max 4 Reinstall the shield and reset the Master Light switch to the ON position Replacement 4...

Страница 15: ...imately 80 degrees Closing the door slowly will minimize the sound OPERATING The variable speed compressor changes speeds and sounds SOUNDS may vary Normal fan air flow one fan blows cold air through...

Страница 16: ...storage bin may cause icemaker to shut off too soon Level cubes in bin Ice cubes stuck in icemaker Turn off the icemaker remove cubes and turn the icemaker back on MOISTURE FORMS Not unusual during p...

Страница 17: ...ndard 42 and Standard 53 for the reduction of substances listed below The following pharmaceutical reduction claims have not been certi ed by NSF International or the state of California Claims tested...

Страница 18: ...18 Notes Bottom Freezer Refrigerator...

Страница 19: ...Contracts In the USA 800 626 2224 In Canada 1 800 561 3344 You can have the secure feeling that GE Consumer Service will still be there after your warranty expires Purchase a GE contract while your w...

Страница 20: ...his warranty is extended to the original purchaser and any succeeding owner for products purchased for ordinary home use in the 48 mainland states Hawaii Washington D C or Canada If the product is loc...

Отзывы: