31-11062
7
2
ELECTRICAL CONNECTIONS (Cont)
B
THREE-CONDUCTOR BRANCH CIRCUIT
CONNECTION
NOTE:
If residence leads are aluminum conductors,
see WARNING on page 5.
When connecting to a three-conductor branch circuit,
if local codes permit:
1. Connect the oven ground conductor along with the
neutral (white) lead to the branch circuit neutral
(white or gray in color), using a wire nut.
2. Connect the oven red lead to the branch circuit red
lead and the oven black lead to the branch circuit
black lead in accordance with local codes, using
wire nuts.
3. Install proper strain relief clamp.
4. Install junction box cover.
Ground and
neutral wires (white)
Tape or Crimp
Neutral wire
connection
Black
Red
Branch
circuit
Alternate
knockout
Range
conduit
snaps
into box
Junction Box Cover
Installation Instructions
3
INSTALLING THE OVEN IN THE
OPENING
1. Lift oven into cabinet cutout using the bottom as a
grip. Do not lift by the oven opening.
2. Carefully slide the oven back into the cutout until it
is about 2” from contacting cabinet face.
3. Attach the free end of the tether to the bottom
of the pizza oven case using the provided
5/8” Phillips case screw.
4. Finish sliding the oven into the cabinet. The oven is
fully installed when the standoffs touch the cabinet
front face.
Tether
Bottom of
Pizza Oven
5/8” Phillips
Case Screw
2” (5.1)
Standoff
Cabinet
Front Face