Installation Instructions
9
CONNECT DRAIN
This ice maker is
equipped with a gravity
drain to prevent water
from flowing back into
the storage bin and
overflowing onto
the floor. The ideal
installation has a
standpipe with a 2”
to 1-1/2” PVC drain
reducer installed directly
below the drain tube:
– A 1” min. physical gap
between the bottom of
the ice maker drain hose
and the top of the house
drain is required. See
illustration.
– 7-1/2” to centerline
of the opening.
– Approximately 3-1/2” high.
– 22” from the front, or
22-3/4” when installing a
3/4” door panel.
• Drain lines must be at least 5/8” inside diameter.
NOTE: A drain pump is necessary when a floor
drain is not available. Order ZPK2 Drain Pump Kit
or contact your local plumber for a recommended
pump available in your area.
TEST DRAIN HOSE ALIGNMENT: Before sliding the
ice maker into the cabinet opening, check to be sure
the bottom of the drain tube is below the rear cover.
To test, place a pan below the drain hose. Slowly
pour a gallon of water into the ice bin and check to
be sure that water does not wet the rear cover.
1-7/8”
22”
22-3/4” with 3/4”
Custom Panel
1” Min. Gap
Drain Hose