WATER SUPPLY

• A cold water supply is required for icemaker

operation. The water pressure must be between 
30 and 120 p.s.i.

• Route GE SmartConnect

Kit or 1/4

O.D. copper

tubing between house cold water line and the water
connection location.

• The water line should be long enough to extend to the

back of the icemaker. Allow enough to accommodate
moving unit forward for service.

NOTE: 

The only GE approved plastic tubing is supplied in

the GE SmartConnect

Refrigerator Tubing kits. Do not

use any other plastic water supply line because the line
is under pressure at all times. Other types of plastic may
crack or rupture with age and cause water damage to
your home. GE SmartConnect

Refrigerator Tubing Kits

are available in the following lengths:

2

(0.6 m) WX08X10002

15

(4.6 m) WX08X10015

6

(1.8 m) WX08X10006

25

(7.6 m) WX08X10025

Shut off the main water supply

Turn on the nearest faucet long enough to clear the
line of water.

Install a shut-off valve between the icemaker water
valve and cold water pipe in a basement or cabinet.
The installation of an easily accessible shut-off valve
in the water line is required.

NOTE: 

It is best to install the valve into a vertical water

pipe. If you install the valve into a horizontal water
pipe, make the connection at the top or side, rather
than at the bottom, to avoid drawing off any sediment
from the water pipe.

• Turn on the main water supply and flush debris from the

line. Run about a quart of water through the tubing into
a bucket. Shut off water supply at the shut-off valve.

NOTE: 

Saddle type shut-off valves are included in many

water supply kits, but are not recommended for this
application.

11-1/2"

9"

Water Supply Should 
Enter From Back Wall
In Shaded Area.

3"

28-1/2"

CONNECT THE DRAIN

This icemaker is
equipped with a gravity
drain to prevent water
from flowing back into 
the storage bin and
overflowing onto the floor.
The ideal installation 
has a standpipe with a 
2

to 1-1/2

PVC drain

reducer installed directly
below the drain tube:

–A 1

min. physical gap

between the bottom of
the icemaker drain hose
and the top of the house
drain is required. See
illustration.

–7-1/2

to centerline 

of the opening.

–Approximately 3-1/2

high.

–22

from the front, or 

22-3/4

when installing a 3/4

door panel.

• Drain lines must be at least 5/8

inside diameter.

NOTE: 

A drain pump is necessary when a floor drain 

is not available. Order ZPK1 Drain Pump Kit or contact
your local plumber for a recommended pump available
in your area.

TEST DRAIN HOSE ALIGNMENT: 

Before sliding the

icemaker into the cabinet opening, check to be sure
the bottom of the drain tube is below the rear cover. 
To test, place a pan below the drain hose. Pour a
gallon of water into the ice bin and check to be sure
that water does not wet the rear cover.

1" Min. Gap

22"

Drain Hose

3-1/2"

22-3/4" With 3/4"

Custom Panel

3-1/2"

High

7-1/2"

Locate Standpipe in exact
Center of The Cutout

15"

WATER SUPPLY 

(cont.)

• Install optional water filter in the water line near the

icemaker. A water filter is recommended in areas
where water supply contains sand or particles.
Installation instructions are packed with the filter.

IMPORTANT:

The performance of the icemaker

may be affected when it is connected to a reverse
osmosis system. An R.O. system may also reduce
water pressure and affect the fill cycle, which is
dependent on time and flow. The reduced water
pressure (less than 30 p.s.i.) may cause the reservoir
not to fill and flush properly during the ice making cycle.

• 

Do not use copper tubing when the icemaker is
connected to a reverse osmosis water system.

NOTE:

Commonwealth of Massachusetts Plumbing

Codes 248CMR shall be adhered to. Saddle valves
are illegal and use is not permitted in Massachusetts.
Consult with your licensed plumber.

6

Содержание ZDI15

Страница 1: ...If you have questions call 800 626 2000 or visit our website at www monogram com Installation Instructions Automatic Icemaker ZDI15 ZDIS15 Design Guide with Installation Instructions...

Страница 2: ...Product failure due to improper installation is not covered under the GE Appliance Warranty See the Owner s Manual for warranty information Use this appliance only for its intended purpose Check with...

Страница 3: ...r Tubing Kit or 1 4 O D copper tubing of sufficient length to reach the installation CUTOUT PRODUCT DIMENSIONS Cutout dimensions shown allow for a full door swing Additional Clearances The installatio...

Страница 4: ...d 90 F 32 C The icemaker may be closed in on the top and three sides as long as the front is unobstructed for air circulation and proper operation Installation should be such that the icemaker can be...

Страница 5: ...EMENT MIS LA TERRE Le non respect de ces instructions peut causer la mort un incendie ou un choc lectrique Do not use an extension cord or adapter plug with this appliance Follow National Electrical C...

Страница 6: ...equipped with a gravity drain to prevent water from flowing back into the storage bin and overflowing onto the floor The ideal installation has a standpipe with a 2 to 1 1 2 PVC drain reducer install...

Страница 7: ...ions including connections at the valve if necessary Water Supply Line REVERSE THE DOOR SWING IMPORTANT Disconnect power to the icemaker Tools Required 1 4 and 5 16 wrench Flat putty knife Phillips sc...

Страница 8: ...ce plastic hinge sleeve on the bottom hinge and position the door onto the pin Place plastic hinge sleeve in the top hinge hole on the door Align the door on the bottom hinge and replace top hinge pin...

Страница 9: ...m panel from the cabinet manufacturer Be sure to provide the exact dimensions so that the panel is constructed accurately BEFORE YOU BEGIN Read these instructions completely and carefully IMPORTANT Sa...

Страница 10: ...y the custom panel appearance side down on a clean surface Align top and bottom side trim to the custom panel sides Tape the side trim pieces to the back of the custom panel Place the panel with trim...

Страница 11: ...11 Notes...

Страница 12: ...asses or goggles should be worn For Monogram local service in your area call 1 800 444 1845 NOTE Product improvement is a continuing endeavor at General Electric Therefore materials appearance and spe...

Отзывы: