18
49-1000500 Rev. 1
PERFORMANCE DATA SHEET
Model: XWFE
Ŷ6\VWHPFHUWLILHGE\,$3025 7DJDLQVW16)$16,6WDQGDUGV3IRUWKHUHGXFWLRQRIFODLPVVSHFLILHGRQWKHSHUIRUPDQFH
data sheet and at iapmort.org.
Ŷ$FWXDOSHUIRUPDQFHPD\YDU\ZLWKORFDOZDWHUFRQGLWLRQV
It is essential that the manufacturer’s recommended installation,
maintenance and filter replacement requirements be carried out for
the product to perform as advertised. See Installation Manual for
Warranty information.
Application Guidelines/Water Supply Parameters
Service Flow
0.5 gpm (1.89 lpm)
Water Supply
Potable Water
Water Pressure
25-120 psi (172-827 kPa)
Water Temperature
33°F-100°F (0.6°C-38°C)
Capacity
170 gallons (643.5 liters)
Substance Tested for Reduction
Influent challenge
concentration
(mg/L)
Maximum permissible
product water
concentration (mg/L)
Avg %
Reduction
Chlorine Taste and Odor
2.0 mg/L +/- 10%
N/A
96.9
Chloramine Taste and Odor
3.0 mg/L +/- 10%
0.5
96.9
Particulate, Class I
At least 10,000/mL
N/A
91.4
Cysts
50,000/L
N/A
>99.99
Lead
0.15
0.01
98.85
Mercury
0.006
0.002
96.3
Asbestos
107 to 108 fibers/ L
N/A
>99
Toxaphene
0.015 +/- 10%
0.003
86.95
VOC (Chloroform surrogate chemical)
0.300
0.015
99.7
Alachlor
0.050
0.001
> 98
Atrazine
0.100
0.003
> 97
Benzene
0.081
0.001
> 99
Carbofuran
0.190
0.001
> 99
carbon tetrachloride
0.078
0.0018
98
chlorobenzene
0.077
0.001
> 99
chloropicrin
0.015
0.0002
99
2,4-D
0.110
0.0017
98
dibromochloropropane (DBCP)
0.052
0.00002
> 99
o-Dichlorobenzene
0.08
0.001
> 99
p-Dichlorobenzene
0.040
0.001
> 98
1,2-dichloroethane
0.088
0.0048
95
1,1-dichloroethylene
0.083
0.001
> 99
cis-1,2-dichloroethylene
0.170
0.0005
> 99
trans-1,2-dichloroethylene
0.086
0.001
> 99
1,2-dichloropropane
0.080
0.001
> 99
cis-1,3-dichloropropylene
0.079
0.001
> 99
dinoseb
0.170
0.0002
99
Endrin
0.053
0.00059
99
Ethylbenzene
0.088
0.001
> 99
ethylene dibromide (EDB)
0.044
0.00002
> 99
bromochloroacetonitrile
0.022
0.0005
98
dibromoacetonitrile
0.024
0.0006
98
dichloroacetonitrile
0.0096
0.0002
98
trichloroacetonitrile
0.015
0.0003
98
1,1-dichloro-2-propanone
0.0072
0.0001
99
1,1,1-trichloro-2-propanone
0.0082
0.0003
96
heptachlor (H-34, Heptox)
0.025
0.00001
>99
heptachlor epoxide
0.0107
0.0002
98
hexachlorobutadiene
0.044
0.001
> 98
hexachlorocyclopentadiene
0.060
0.000002
> 99
Lindane
0.055
0.00001
> 99
methoxychlor
0.050
0.0001
> 99
pentachlorophenol
0.096
0.001
> 99
simazine
0.120
0.004
> 97
Styrene
0.150
0.0005
> 99
1,1,2,2-tetrachloroethane
0.081
0.001
> 99
Tetrachloroethylene
0.081
0.001
> 99
Toluene
0.078
0.001
> 99
2,4,5-TP (silvex)
0.270
0.0016
99
tribromoacetic acid
0.042
0.001
> 98
1,2,4-Trichlorobenzene
0.160
0.0005
> 99
1,1,1-trichloroethane
0.084
0.0046
95
1,1,2-trichloroethane
0.150
0.0005
> 99
trichloroethylene
0.180
0.0010
> 99
bromoform
0.300
0.015
95
bromodichloromethane
0.300
0.015
95
chlorodibromomethane
0.300
0.015
95
xylenes
0.070
0.001
>99
Meprobamate
400 +/- 20%
60
95.5
Atenolol
200 +/- 20%
30
95.9
Carbamazepine
1400 +/- 20%
200
98.6
DEET
1400 +/- 20%
200
98.6
Metolachlor
1400 +/- 20%
200
98.7
Trimethoprim
140 +/- 20%
20
96.1
Linuron
140 +/- 20%
20
96.6
TCEP
5000 +/- 20%
700
98.1
TCPP
5000 +/- 20%
700
98.1
Phenytoin
200 +/- 20%
30
96
Ibuprofen
400 +/- 20%
60
95.9
Naproxen
140 +/- 20%
20
96.5
Estrone
140 +/- 20%
20
97.1
Bisphenol A
2000 +/- 20%
300
99.1
Nonyl phenol
1400 +/- 20%
200
97.3
PFOA/PFOS
1.5 mg/L +/- 10%
0.07
99.25
NOTE:
While the testing was performed under standard
laboratory conditions, actual performance may vary.
Replacement Cartridge: XWFE. For estimated costs
of replacement elements please visit our website at
gewaterfilters.com
.
WARNING
To reduce the risk associated with
ingestion of contaminants:
•
Do not use with water that is microbiologically
unsafe or of unknown quality without adequate
disinfection before and after the system.
Systems
certified for cyst reduction may be used on disinfected
water that may contain filterable cysts.
NOTICE
To reduce the risk of water leakage or flooding, and
to ensure optimal filter performance:
•
Read and follow
use instructions before installation and
use of this system.
• Installation and use
MUST
comply with all state and
local plumbing codes.
•
Do not
install if water pressure exceeds 120 psi (827
kPa). If your water pressure exceeds 80 psi (552 kPa),
you
must
install a pressure-limiting valve. Contact a
plumbing professional if you are uncertain how to check
your water pressure.
•
Do not
install where water hammer conditions may
occur. If water hammer conditions exist you
must
install a water hammer arrester. Contact a plumbing
professional if you are uncertain how to check for this
condition.
•
Do not
install on hot water supply lines. The maximum
operating water temperature of this filter system is 100º
F (38º C).
•
Protect filter from freezing.
Drain filter when
temperatures drop below 33ºF (0.6ºC).
• Change the disposable filter cartridge every six months
or sooner if you observe a noticeable reduction in water
flow rate.
• Failure to replace the disposable filter cartridge at
recommended intervals may lead to reduced filter
performance and cracks in the filter housing, causing
water leakage or flooding.
• This System has been tested according to NSF/ANSI
42, 53, 401 and P473 for the reduction of the substances
listed below. The concentration of the indicated
substances in water entering the system was reduced
to a concentration less than or equal to the permissible
limit for water leaving the system, as specified in NSF/
ANSI 42, 53, 401 and P473.
XWFE System is certified by IAPMO R&T
against NSF/ANSI Standards 42,53, 401 and
P473 for the reduction of claims specified on
the performance data sheet and at
iapmort.org.
Содержание Wine Sommelier ZIW303NPPII
Страница 20: ...49 1000500 Rev 4 09 20 GEA Printed in Slovenia...
Страница 40: ...49 1000500 Rev 1 09 20 GEA Imprim en Slovenia...
Страница 60: ...49 1000500 Rev 1 09 20 GEA Impreso en Slovenia...