1.
Using the template, mark out 310 mm opening for
SUNPIPE and 11 mm fixing holes. If possible, use the stud
finder to avoid ceiling obstructions.
2.
Cut opening, and drill fixing Ø11 mm hole positions for
spring toggle clamps. The fixing template can be used to
mark positions.
3.
Run power cables from existing lighting circuit to opening.
Position fixing template above ceiling if required.
4.
Remove diffuser from SUNPIPE LuxLoop.
5.
Insert SUNPIPE Slip Length into LuxLoop luminaire.
6.
Fasten SUNPIPE length to angle brackets using pipe
screws provided.
7.
Adhere white seal to outside of pipe around the join
between pipe and luminaire.
8.
Place black sponge seal around the outside of the offered
length of SUNPIPE in the roof void.