F. 

The pie chart in the Aware or Not Aware Section displays the percentage of aware states 

your sensor has entered since activation. 

History View

Selecting the “History” tab within the tab bar allows you to view the sensor’s data history as 

time stamped data. 

• 

On the far right of the sensor history data is a cloud icon. 

 Selecting this icon will 

export an excel file for your sensor into your download folder.

Note: 

Make sure you have the date range for the data you need input in the “From” and “To” text boxes. This will be 

the most recent week by default. Only the first 2,500 entries in the selected date range will be exported. 

The data file will have the following fields: 

MessageID: 

Unique identifier of the message in our database.

SensorID:

 If multiple sensors are exported you can distinguish which reading was from 

which using this number even if the names for some reason are the same.

Sensor Name:

 The name you have given the sensor.

Date:

 The date the message was transmitted from the sensor.

Value: 

Data presented with transformations applied but without additional labels.

Formatted Value: 

Data transformed and presented as it is shown in the monitoring portal.

Battery: 

Estimated life remaining of the battery.

Raw Data: 

Raw data as it is stored from the sensor.

Sensor State:

 Binary field represented as an integer containing information about the state 

or the sensor when the message was transmitted. (See “Sensor State Explained” below).

Gateway ID: 

The Identifier of the gateway that relayed the data from the sensor.

Alert Sent: 

Boolean indicating if this reading triggered a notification to be sent from the 

system.

Signal Strength: 

Strength of communication signal between the sensor and the gateway, 

shown as percentage value.

Voltage:

 Actual voltage measured at the sensor battery used to calculate battery percent-

age, similar to Received Signal you can use one or the other or both if they help you.

PAGE  9

Содержание ALTA Water Detection Puck Sensor

Страница 1: ...by ALTA Water Detection Puck Sensor User Guide...

Страница 2: ...ETECTION PUCK V SETTING UP THE WATER DETECTION PUCK INSTALLING BATTERIES VI SENSOR OVERVIEW MENU SYSTEM SUPPORT WARRANTY INFORMATION PAGE II 2 3 3 4 4 6 7 II SENSOR SECURITY SENSOR COMMUNICATION SECUR...

Страница 3: ...d notification system to configure sensors view data and set alerts via SMS text and email Response time to iMonnit 3 seconds Actual range may vary depending on environment Battery life is determined...

Страница 4: ...pplication data Wireless devices listening on open communication protocols cannot eavesdrop on sensors Packet level encryption and verification is key to ensuring traffic isn t altered between sensors...

Страница 5: ...ish to add onto your network must come after the gateway 2 Register your ALTA Water Detection Puck on iMonnit After you ve registered your gateway it s time to add your Water Detection Puck to the iMo...

Страница 6: ...he Security Code from your Water Detection Puck in the corresponding text boxes Use the camera on your smartphone to scan the QR code on your sensor and gateway If you do not have a camera on your pho...

Страница 7: ...line powered version also uses two standard 1 5 V AA batteries as backup for uninterrupted operation in the event of line power outage Power options must be selected at time of purchase as the intern...

Страница 8: ...g vertically from the sensor If the sensor is mounted flat on its back on a horizontal surface you should bend the antenna as close to the sensor housing as possible giving you the most amount of ante...

Страница 9: ...tion Puck is alerted when water build up of at least 3mm occurs A magnetic reed switch has been installed in the sensor to detect the presence of a magnetic field Its purpose is to allow you to put th...

Страница 10: ...that no sensor readings are being recorded rendering the sensor inactive Details View The Details View will be the first page you see upon selecting which sensor you would like to modify A The sensor...

Страница 11: ...names for some reason are the same Sensor Name The name you have given the sensor Date The date the message was transmitted from the sensor Value Data presented with transformations applied but withou...

Страница 12: ...State The integer presented here is generated from a single byte of stored data A byte consists of 8 bits of data that we read as Boolean True 1 False 0 fields PAGE 10...

Страница 13: ...m a gateway before it goes to battery saving link mode In link mode the sensor will scan for a new gateway and if not found will enter battery saving sleep mode for up to 60 minutes before trying to s...

Страница 14: ...of such non conformance and ii the non conforming Product provid ed however if in its opinion Monnit cannot repair or replace on commercially reasonable terms it may choose to refund the purchase pric...

Страница 15: ...IITY WHETHER IN CONTRACT IN TORT UNDER ANY WARRANTY IN NEGLIGENCE OR OTHERWISE SHALL NOT EXCEED THE PURCHASE PRICE PAID BY CUSTOMER FOR THE PRODUCT UNDER NO CIRCUMSTANCES SHALL MONNIT BE LIABLE FOR SP...

Страница 16: ...or an experienced radio TV technician for help Warning Changes or modifications not expressly approved by Monnit could void the user s authority to operate the equipment RF Exposure WARNING To satisf...

Страница 17: ...evice French Conform ment la r glementation d Industrie Canada le pr sent metteur radio peut fonctionner avec une antenne d un type et d un gain maximal ou inf rieur approuv pour l metteur par Industr...

Страница 18: ...lly the instruction for its use Do not insert or remove the SIM when the product is in power saving mode Every device has to be equipped with a proper antenna with specific characteristics The antenna...

Отзывы: