![MONKEY GRIP SPEED DRIVE 17045-MG Скачать руководство пользователя страница 7](http://html1.mh-extra.com/html/monkey-grip/speed-drive-17045-mg/speed-drive-17045-mg_instructions-for-use-manual_1827347007.webp)
7
MAINTENANCE
TROUBLE SHOOTING
THE INFLATOR FAILS TO RUN WITH THE INFLATOR POWER BUTTON TURNED ON OR DIGITAL
PRESSURE GAUGE DOES NOT ILLUMINATE:
� Check that the plug is fully inserted into 12 Volt DC power outlet
� Your vehicle may require the ignition be turned to the accessory position for the power outlet to
have power. The inflator should be used with the vehicle running
� Check to see if the fuse in the 12 Volt power plug has blown. See fuse replacement instructions
in the maintenance section
INFLATOR FAILS TO STOP AT THE AUTO SHUT-OFF PRE-SET PRESSURE:
� Check to make sure auto shut-off pressure settings are being set correctly
� Check that the correct pre-set pressure has been set
� Check that the SmartSTOP
™
feature is active
12 VOLT POWER CORD GETS HOT:
� Make certain power cord is not coiled up or in a knot or damaged
PRESSURE GAUGE APPEARS TO READ INCORRECTLY OR IS UNREADABLE:
� Make certain when you attach the air hose nozzle to the tire stem that the gauge is reading the
current tire pressure before turning on the inflator switch
� Wait 5-7 seconds for gauge to display proper pressure
THE INFLATOR IS RUNNING BUT THE TIRE IS NOT INFLATING:
� Turn off the inflator and check that the air hose nozzle is securely attached to the tire valve stem
� Check if tire has too large of leak to fill
DIGITAL DISPLAY SHOWS ERROR MESSAGE:
� E-1 error message will be displayed if the tire has too large of a leak that the tire cannot be filled
or if inflator is running but not attached to tire. Recheck puncture is well sealed and air hose
nozzle is connected to vehicle tire valve stem
� E-2 error message will be displayed if the inflator reaches above 150 PSI (over pressure shut-down)
When E-2 appears, press inflator power button. Inflator should be off. See digital gauge reset.
DIGITAL DISPLAY SHOWS “
0
” WHEN TIRE HAS PRESSURE:
� Perform DIGITAL GAUGE RESET below
DIGITAL GAUGE RESET:
� Make certain the inflator has power and the inflator pump is OFF. Make certain the air hose
nozzle is connected to the tire stem. Let the gauge adjust for a few seconds. Press and hold the
“M” button for a few seconds to reset the pressure sensor. Remove the air hose from the tire
and reattach air hose to tire and proceed with normal inflator operation.
NOTE:
The inflator will not reset if the pump is running
1. Your
SmartSTOP
™
inflator has a replaceable fuse providing maximum protection for the inflator
and/or your vehicle.
2. Regularly check inflator air hose, 12 Volt cord and adapters for damage.
Fuse
: Replace with fast blow 15 AMP, 250V, " x ¾" (5mm x 20mm), glass fuse only.
16
Turn tip counterclockwise to
unlock Fuse Adapter Body
Adapter Body
12 Volt Adapter Fuse Replacement