background image

Monitor Technologies LLC

44W320 Keslinger Rd.  

t

Elburn, IL 60119   

t

630-365-9403   

t

800-766-6486  

t

Fax: 630-365-5646   

t

www.monitortech.com

B U L L E T I N

344H

SAFET Y

Monitor  Technologies  LLC  warrants  each 

Wireless

EZ

Communications  Interface  it  manufactures  to  be  free  from

defects  in  material  and  workmanship  under  normal  use  and

service for two (2) years from the date of purchase.  The pur-

chaser must notify Monitor of any defects within the warranty

period,  return  the  product  intact,  and  prepay  transportation

charges.  The obligation of Monitor Technologies LLC under this

warranty is limited to repair or replacement at its factory.  This

warranty  does  not  apply  to  any  product  which  is  repaired  or

altered outside of Monitor Technologies’  factory, or which has

been subject to misuse, negligence, accident, incorrect wiring by

others,  or  improper  installation.    Monitor  Technologies  LLC

reserves  the  right  to  change  the  design  and/or  specifications

without prior notice.

WARRANT Y

  

Power Requirements:        85 to 265 VAC (±15%); 8VA; 

                                           50/60Hz

Ambient Operating Temp:  -40° to +150° F (-40° to +65° C)

Data Input Signal:              RS-485 half-duplex, isolated

Wiring Distance:                3,279 ft. (1,000m)

Radio Output:                    900MHz (North America); 1W

Radio Sensitivity:               -110dBm

Conduit Entry:                    Two 0.88in (22.4mm) dia. holes 

Indicators:                          Orange LED: Tx

                                           Yellow LED: Rx

                                           Green LED: Power

Housing:                            Powder coated die cast aluminum, 

                                           IP66

Mounting:                           Wall or pipe/rail

                                           CHINA RoHS 2

SPECIFICATIONS

MECHANICALS

WirelessEZ Communication Interface

Left: Standard Antenna

Center: high Gain Antenna

Right: Yagi Antenna

DIMENSIONS ARE ShOWN IN INChES WITh MILLIMETER EqUIVALENT IN BRACkETS

General Safety:

CAUTION!

It is essential that all instructions in this man-

ual be followed to ensure proper operation of the equip-

ment and safety of operating personnel.  The use of this

symbol is used throughout manual to highlight important

safety  issues.    Please  pay  particular  attention  to  these

items.

       Electrical Shock Caution:

Certain 

Wireless

EZ

Communication  Interfaces  are  pow-

ered with HIGH VOLTAGE.  No operator serviceable parts

are  inside.   All  servicing  is  to  be  performed  by  qualified

personnel.  Each 

Wireless

EZ

Communication Interface is

provided with a “protective conductor terminal” which shall

be  terminated  to  earth  ground  potential  (See  Electrical

Installation).    This  product's  design  complies  with

EN61010-1 overvoltage category II and pollution degree

2.  When installing certain high performance antennas, it

is critically important that the antenna not come in contact

with overhead power lines.  Doing such may put operators

at risk of electrical shock that may be harmful or fatal.

Electromagnetic Compatibility (EMC):

The 

Wireless

EZ

Communications  Interface  contains

transmitter module FCC ID: OUR-9XTEND. This enclosed

device complies with Part 15 of the FCC Rules.  Operation

is subject to the following two conditions.

    1.  This device may not cause harmful interference

    2.  This device must accept any interference received,

        including interference that may cause undesired 

        operation.

GDR

JSC

MAY 19 2017

DOC-001-344H      4

Содержание WirelessEZ

Страница 1: ...e safety of all personnel Before discarding shipping container or the internal packing materials please inspect the packaging thoroughly and verify that all parts are accounted for This product is shi...

Страница 2: ...In some challenging applications it maybe necessary to install a higher performance antenna that requires co axial cabling between the radio and the antenna The co axial cable introduces loss into th...

Страница 3: ...en 6 lower then the box with a means to disperse any accu mulated water in the conduit so that water does not pour into the box Likewise if installing with cable and the cord connectors provided posit...

Страница 4: ...176 F 80 C minimum Protective Earthing Each WirelessEZ Communication Interface is provided with a protective conductor terminal which shall be ter minated to the local earth ground potential This term...

Страница 5: ...n 9322 or Alpha 6302 The order of connection is not important i e the WirelessEZ Communication Interface can be connected between SMUs if necessary The WirelessEZ Communication Interface creates a wir...

Страница 6: ...6 Figure 9...

Страница 7: ...on is used to terminate the RS 485 link to achieve maximum communication reliability If no RS 485 communica tions is to be used simply turn OFF this selection If there is to be RS485 communications th...

Страница 8: ...e insure cover is fully engaged and that wire entries are properly sealed Cleaning Requirements In the event that the antenna is fouled by external contam ination reliable communication of the RF wire...

Страница 9: ...WirelessEZ Communication Interface 2 Verify electrical power is connected that it is the proper voltage as indicated on the nameplate and that the magnitude is within the specified limits 3 Verify sta...

Страница 10: ...MECHANICALS WirelessEZ Communication Interface Left Standard Antenna Center high Gain Antenna Right Yagi Antenna DIMENSIONS ARE ShOWN IN INChES WITh MILLIMETER EqUIVALENT IN BRACkETS General Safety C...

Отзывы: