background image

11

12

OPERATION  TIPS

The following events may occur during normal operation.
1.  Protection of the air conditioner.
         

Compressor protection

         The compressor can't restart for 3 minutes after it stops.
         

Anti-cold air 

(Cooling and heating  models only)

         The unit is designed not to blow cold air on HEAT mode, when the indoor heat 
         exchanger is in one of the following three situations and the set temperature has not 
         been reached.
         A)  When heating has just start

ed

.

         B)  Defrosting.
         C)  Low temperature heating.
         The indoor or outdoor fan 

will 

stop running when defrosting (Cooling and heating 

         

models only).

         

Defrosting

 (Cooling and heating models only)

         Frost may be generated on the outdoor unit during 

the 

heat cycle when outdoor temperature 

         is low and humidity is high

. This will 

result in lower heating efficiency of the air conditioner. 

         During this condition air conditioner will stop heating operation and start defrosting 
         automatically.
         The time to defrost may vary from 4 to 10 minutes according to the outdoor temperature 
         and the amount of frost build up on the outdoor unit.

2. A white mist coming out from the indoor unit
         A white mist may 

appear

 due to a large temperature difference between 

the 

air

-

inlet

s

  

         

and 

air

-

outlet

s

 on COOL mo

de when there is

 high relative humidity

 indoors

.

         A white mist may 

appear

 due to moisture from 

the 

defrosting process 

if the air 

 

        

 

conditioner restarts in HEAT mode after defrosting.

3. Low noise of the air conditioner
         You may hear a low hissing sound when the compressor is running or has just stopped 
         running. This sound is the

 

refrigerant flowing or coming to a stop.

         You can also hear a low "squeak" sound when the compressor is running or has just 
         stopped running. This is caused by 

the 

heat expansion 

and/or 

cold contraction of the  

         

plastic 

parts in

side

 the unit  when the temperature is changing.

         A noise may be heard due to louver restoring to its original position when power is first 
        

 

turned on.

4. Dust is blown out from the indoor unit.
    This is a normal when the air conditioner has not been used for a long time or 
    during first use of the unit.

5. A peculiar smell comes from the indoor unit.
    This is caused by the indoor unit giving off smells permeated from building material, from 
    furniture, or smoke. 

6. The air conditioner turns to FAN only mode from COOL or HEAT (For cooling and 
     heating models only) mode.
    When indoor temperature reaches the temperature setting on 

the unit

, the compressor 

    

will stop automatically and 

switch

 to FAN only mode.  The compressor will start again 

    

when the indoor temperature rises on COOL mode or falls on HEAT mode (For cooling 

    

and heating models only).

CARE  AND  MAINTENANCE

Maintenance 

Checks before operation

    If you plan to idle the unit for a long time, perform
    the following:
   (1) Operate the fan for about half a day to dry the 
         inside of the unit.
   (2) Stop the air conditioner and disconnect power. 
         Remove the batteries from the remote control.
   (3) The outdoor unit requires periodic maintenance 
         and  cleaning. Do not attempt to do this yourself. 
         Contact  your dealer or servicer.

   Check that the wiring is not broken or 
   disconnected.
   Check that the air filter is installed.
   Check

 that

 the air

-

outlet

s

 or 

air-

inlet

sare not

 

   

blocked after the air conditioner has not been 

   

used for a long time.

   
   
  

    Do not touch the metal parts of the unit when 
    removing the filter. Injuries can occur when 
    handling sharp metal edges.
    Do not use water to clean inside the air conditioner.
    Exposure to water can destroy the insulation, 
    

and also 

lead to possible electric shock.

    When cleaning the unit, first make sure that the 
    power and circuit breaker are turned off. 

Caution

Air freshening filter

Air freshening filter

1

2

4. Remove the  Air Freshening Filter from its support 
     frame (on some models).
    (The optional filter include :Plasma Dust Collector/
      Silver Ion filter/

 

Bio filter/

 

Vitamin C filter/

 

3M air 

      purifier filter, etc. The removing and installation 
      methods are slightly different, see the pictures 
      marked       and       on the left. 
       Clean the air freshening filter at least once a 
        month and replace it every 4-5 months.
       Clean it with vacuum cleaner, then dry

 (if 

       necessary)

.

5. Install the air freshening filter back into position.
6. Insert the upper portion of air filter back into the 
    unit,  

making sure

 that the left and right edges line 

    up correctly

,

 and place filter 

back 

into position.

.

.

1

2

Do not touch the Plasma Dust Collector 
Filter within 10 minutes after opening the 
front pane

l.

 

I

t may cause an electric shock.

Содержание CS002U-BP9A1

Страница 1: ...n your part can save you a great deal of time and money over the life of your air conditioner You ll find many answers to common problems in the chart of troubleshooting tips If you review the chart o...

Страница 2: ...rformed in accordance with the national electrical codes by authorised personnel only CAUTION Conservation Alert DISPOSAL Do not dispose of this product as unsorted municipal waste Collection of such...

Страница 3: ...Do not use the power cord near flammable gas or combustibles such as gasoline benzene thinner etc Do not disassemble or modify the unit WARNING Use the correctly rated circuit breaker or fuse There i...

Страница 4: ...Auto indicator This indicator illuminates when the air conditioner is in AUTO operation Timer indicator This indicator illuminates when TIMER is set ON OFF Defrost Indicator For cooling heating model...

Страница 5: ...ly energized the horizontal louver may generate a sound for 10 seconds This is normal CAUTION Manual operation can be used temporarily if the remote control is disabled or if maintenance is necessary...

Страница 6: ...n the temperature you have selected and the temperature of the room The air conditioner will control room temperature automatically around the temperature set by you If the AUTO mode is uncomfortable...

Страница 7: ...nit This is caused by the indoor unit giving off smells permeated from building material from furniture or smoke 6 The air conditioner turns to FAN only mode from COOL or HEAT For cooling and heating...

Страница 8: ...t during the heating operation When the outdoor temperature falls heat drawn in by the unit decreases accordingly At the same time heat loading of the unit increases due to larger differences between...

Отзывы: