WARRANT Y

SPECIFICATIONS

       General Safety 

CAUTION:  It is essential that all instructions in this manual be

followed to ensure proper operation of the equipment and safety

of operating personnel.  The use of this symbol is used through-

out this manual to highlight important safety issues.  Please pay

particular attention to these items.

       Electrical Shock Caution

All tilt switches may be configured to “switch” HIGH VOLTAGE

depending on the application requirements. To avoid electrical

shock,  remove  power  before  opening  enclosure.  Each  unit  is

provided with a “protective ground” connection which shall be

terminated to earth ground potential. This terminal shall be used

to eliminate shock hazard in the unlikely event of internal insula-

tion breakdown.

SAFET Y

Monitor Technologies LLC warrants each tilt switch it manufac-

tures to be free from defects in material and workmanship under

normal use and service within two (2) years from the date of pur-

chase. The purchaser must give notice of any defect to Monitor

within the warranty period, return the product intact and prepay

transportation charges. The obligation of Monitor Technologies

LLC under this warranty is limited to repair or replacement at its

factory. This  warranty  shall  not  apply  to  any  product  which  is

repaired or altered outside of the Monitor Technologies LLC fac-

tory, or which has been subject to misuse, negligence, accident,

incorrect  wiring  by  others  or  improper  installation.    Monitor

Technologies LLC reserves the right to change the design and/or

specifications without prior notice.

 Model TC-3

     Power Requirements:     None

     Output:                            SPDT, 10A @ 250 VAC max

    Sensitivity:                      17˚ from vertical axis

     Enclosure:                       Cast aluminum, unpainted

     Enclosure Protection:     NEMA 4, IP56

     Mounting Connection:     Eyebolt, 3/4 in (19mm) I.D.

     Wire Entry:                      3/8" NPT cord connector

                                             Cord dia 0.25-0.38 in (6.4-9.6mm)

     Operating Temperature:  -40˚ to 175˚F (-40˚ to 80˚C)

     Weight:                            3lb (1.35kg)

     

     Approvals:                       CE Mark

          

                                             

CHINA RoHS 2

 Model TC-1

     Power Requirements:     None

     Output:                            SPDT, 15A @ 250 VAC max

     Sensitivity                       17˚ from vertical axis

     Enclosure                        Cast iron, painted beige

     Enclosure Protection      NEMA 4, IP56

     Mounting Connection      Eyebolt, 1-3/32 in (27.7mm) I.D.

     Wire Entry                       1/2" NPT cord connector 

                                             Cord dia 0.25-0.38 in (6.4-9.6mm)

     Operating Temperature   -40˚ to 250˚F (-40˚ to 121˚C)

     Weight                             24lb (11.25kg)

     

Approvals:                            CE Mark

                                             

CHINA RoHS 2

MECHANICALS

B U L L E T I N

634

DIMENSIONS ARE SHOWN IN INCHES WITH MILLIMETER EQUIVALENT IN BRACKETS

OPTIONAL ACCESSORIES (TC-3)

PART #

DESCRIPTION

4-8001

TC-3 Extension actuator, 20” overall extension length, 

stainless steel extension and ball float.

4-8002

TC-3 Extension actuator, 20” overall extension length, 

galvanized steel extension and polypropylene ball float.

4-8001

4-8002

20.53 + .19

[522 + 5]

8.12

[206]

20.53 + .19

[522 + 5]

8.25

[210]

7.00

[     178]

8.00

[    203]

.75

[19]

GDR

JSC

AUG 05 2016

DOC-001-634A      12

DIMENSIONS ARE SHOWN IN INCHES WITH MILLIMETER EQUIVALENT IN BRACKETS

Содержание TC-1

Страница 1: ...Y Doing so will ensure proper oper ation of the equipment and the safety of all personnel Before discarding shipping container please inspect it thoroughly and verify that all parts ordered are accounted for Sometimes smaller parts become stuck under carton flaps and other packaging materials In the event that information contained herein does not completely sat isfy your requirements or answer yo...

Страница 2: ...AL INSTALL ATION PRE INSTALL ATION CONSIDERATIONS 2 ELECTRICAL INSTALL ATION Figure 1 Figure 2 Figure 3 Suspension of Tilt Switch See Figure 2 Locate or fabricate a structural brace to support the full weight of a suspended tilt switch and extension actuator if used Interconnect the structural brace and the tilt switch with a rigid or flexible hanger e g wire rope chain Never hang tilt switch by i...

Страница 3: ...ection 3 Verify electrical connection When in material sensed mode tilted the N O contact is open to COM and the N C contact is closed to COM If necessary change wiring orientation 4 Verify that the internal steel ball actuates the switch when positioned in the center of the cage If necessary adjust position of internal switch per Maintenance section The tilt switches require no calibration or set...

Страница 4: ...c tory or which has been subject to misuse negligence accident incorrect wiring by others or improper installation Monitor Technologies LLC reserves the right to change the design and or specifications without prior notice Model TC 3 Power Requirements None Output SPDT 10A 250 VAC max Sensitivity 17 from vertical axis Enclosure Cast aluminum unpainted Enclosure Protection NEMA 4 IP56 Mounting Conn...

Отзывы: