Fuel Calibration (G-200+ only)
The G-200+’s fuel measurement system is designed to work with a wide range
of tank sizes and shapes. Before it can be used, the system must be calibrated
to suit your particular vehicle. This is done using a special calibration wizard
that guides you through the process using simple on-screen instructions.
To calibrate the fuel system:
Find a safe place to add and remove fuel from your vehicle. To perform
1.
the calibration, you will need enough fuel to fill the tank completely and a
5-10 litre container that you can use to measure the amount of fuel being
added.
Empty all the fuel from the tank.
2.
From the Main Menu select Calibration > Cal. Fuel to start the calibration
3.
wizard.
Follow the instructions on the screen.
4.
Getting Started
Getting Started
The calibration wizard works by recording a number of set points as you add
fuel to the tank. For best results:
Use at least five set points (up to a maximum of ten).
•
Add about 5 to 10 litres of fuel between each point
•
Notes: Many vehicles will not give a correct fuel signal unless the ignition
is turned on. The device will not lose its calibration if the power supply is
disconnected.