Monicon Instruments GTR-168 Скачать руководство пользователя страница 5

 Monicon 

Tech.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

  

Ver.:V168007 4 

GTR-168

5. Specifications

 

DC supply

 

8~36 VDC 

Power Consumption

 

Max.5 W 

Measuring

 Frequency

 

0

75 Hz (min AC Volt. 5V ; max AC Volt. 300V) 

Relay Output 

 

Start output

5A 

Valve output

5A 

Idle / 

Pre

-heat output

5A 

Alarm Output

5A 

Stop 

output

5A 

Ambient Temperature Range

 

-30  

 70 

 

Dimension (W * H * D)

 

72mm × 72 mm × 58 mm 

Panel cut-out (W * H)

 

68 mm × 68 mm 

Weight

 

190 g (0.42 lb.) 

6. Protections and parameters

 

Auxiliary shutdown protection: 1 Sec., Normal Close 

Low battery warning: 5 Sec., 10.5 / 21 VDC 

Over speed protection: 2 Sec., 55/66 Hz 

High water temp. protection: 2 Sec., Normal Open 

Low oil pressure protection: 2 Sec., Normal Open / Normal Close 

Over crank: 3 attempts 

Cranking speed up limited: 0.5 Sec., 16Hz 

Safety on timer: 5 Sec (*) 

(*) All alarms are ignored until safety on timer expired, except the emergency stop and over speed. 

 

 

 

 

 