SS38 Direct Vent Gas Stove
CLEARANCES
CLEARANCES TO COMBUSTIBLES
Maintain the following minimum clearances for service and maintenance.
•
Stove must be at least 6" from the back wall.
Figure 4
•
Stove must be at least 9" from either side wall.
See Figure 4
•
Stove must be at least 6" from the corner.
Figure 4
•
No clearance is necessary to the floor. Stove may sit on the floor.
Figure 5
•
The minimum ceiling height from the floor must be 72".
The dimensions shown in
Figures 4 and 5
are minimum clearances to maintain
in installing this heater. Left and right clearances are determined when facing the
front of the heater.
Follow these instructions carefully to ensure safe installation. Failure to follow
instructions exactly can create a fire hazard.
The appliance cannot be installed on a carpet, tile or other combustible material
other than wood flooring. If installed on carpet or vinyl flooring, the appliance
shall be installed on a metal, wood or noncombustible material panel extending
full width and depth of the appliance.
W
ARNING
Figure 4 -
Clearances to Side, Back and Adjacent Walls
ST1101
clearances
6" Min.
9"
Minimum
to Either
Side Wall
Back Wall
Side W
all
Adjacent W
all
6" Minimum
Clearance to
Corner
Figure 5 -
Clearance to Floor
0"
ST1102
floor clearance