23
46D0232
SS38 Direct Vent Gas Stove
ELECTRICAL INSTALLATION
ELECTRICAL WIRING
This stove will work without any electrical supply. Electricity is only needed to operate blower.
NOTE: If installed in mobile home, stove must be bolted securely to floor.
W
ARNING
Electrical connections should only
be performed by a qualified, licensed
electrician. Main power must be off when
connecting to main electrical power supply
or performing service. All wiring shall be
in compliance with all local, city and state
codes. The appliance, when installed, must
be electrically grounded in accordance with
local codes or in the absence of local codes,
with the National Electrical Code ANSI/NFPA
70 (latest edition) and Canadian Electrical
Code, CSA C22.1.
CAUTION
Label all wires before disconnecting when
servicing controls. Wiring errors can cause
improper and dangerous operation.
Verify proper operation after servicing.
REMOTE WALL MOUNTED SWITCH
A remote wall switch and up to fifteen (15) feet of 18 Ga. wire may be used with this appliance. Attach
the wall switch in a junction box at the desired location on the wall.
Figure 31
. Do not extend beyond
the wall switch wire length provided.
NOTE:
Extended lengths of wire may cause the stove not to function properly. Longer length
of wire is permitted if the wire is made out of larger gauge (diameter) wire. Always check with
local code.
ON
OFF
OPTIONAL REMOTE
WALL SWITCH
ON
OFF
OPTIONAL REMOTE
WALL SWITCH
PILOT
HI
LO
ON
OFF
TH
TP
TH/TP
ON
OFF
RS
FP1980
Dv wiring diagram
Figure 31 -
Wiring Diagram for Wall Switch