VENT INSTALLATION
BELOW GRADE INSTALLATIONS
When it is not possible to meet the required vent terminal clearances of 12" above grade level, a snorkel kit is
recommended. It allows installation depth down to 7" (178mm) below grade level. The 7" (178mm) is measured
from the center of the horizontal vent pipe as it penetrates through the wall.
Ensure that sidewall venting clearances are observed. If venting system is installed below ground, we rec-
ommend a window well with adequate and proper drainage to be installed around the termination area.
If installing a snorkel, a minimum 24" vertical rise is necessary. The maximum horizontal run with the 24” verti-
cal pipe is 36". This measurement is taken from the collar of the fireplace (or transition elbow) to the face of the
exterior wall. See the Sidewall Venting Graph for extended horizontal run if the vertical exceeds 24".
1. Establish vent hole through the wall.
2. Remove soil to a depth of approximately 16" below base of snorkel. Install drain pipe. Install window well (not
supplied). Refill hole with 12" of coarse gravel leaving a clearance of approximately 4" below snorkel.
Figure
21.
3. Install vent system.
4. Ensure a watertight seal is made around the vent pipe coming through the wall.
5. Apply high temperature sealant caulking (supplied) around the 4" and 7" snorkel collars.
6. Slide the snorkel into the vent pipes and secure to the wall.
7. Level the soil so as to maintain a 4" clearance below snorkel.
Figure 21.
Figure 22 - Snorkel Installation,
Recessed Foundation
Figure 21 - Below Grade Installation
Screws
Minimum
4" Clearance
Ground
Window Well
Gravel
Drain
Foundation Wall
Firestop
12"
Minimum
Foundation
Recess
Watertight Seal
Around Pipe
Sheet Metal
Screws
Wall Screws
Snorkel
• Do not back fill around snorkel.
• A clearance of at least 4" must be maintained between the
snorkel and the soil.
W
ARNING
If the foundation is recessed, use recess brackets (not supplied) for securing lower portion of the snorkel. Fasten
brackets to wall first, then secure to snorkel with self drilling #8 x 1/2 sheet metal screws. It will be necessary to
extend vent pipes out as far as the protruding wall face.
Figure 22.
Содержание Direct Vent BLDV400
Страница 54: ...54 74D0009 2 3 4 5 6 7 illustrated parts lists firebox components ...
Страница 56: ...56 74D0009 illustrated parts lists 1 2 3 4 5 6 7 8 10 11 12 13 14 Standing Pilot Millivolt control 2T 2I 2C 8 ...
Страница 58: ...58 74D0009 illustrated parts lists SIGNATURE COMMAND SYSTEM 0009 SG parts 8 08 1 2 3 4 17 5 6 7 8 9 13 14 15 ...
Страница 65: ...74D0009 65 ...
Страница 66: ...66 74D0009 ...
Страница 68: ...68 74D0009 NOVEMBER 2008 74D0009 Rev 11 MHSC 149 Cleveland Drive Paris Kentucky 40361 www mhsc com ...