background image

3

CFX Vent Free Fireplace System

20301726

11.  Correct installation of the ceramic fiber logs, proper 

location of the heater, and annual cleaning are neces-
sary to avoid potential problems with sooting. Sooting, 
resulting from improper installation or operation, can 
settle on surfaces outside the fireplace. See log place-
ment instructions for proper installation.

12.  Avoid any drafts that alter burner flame patterns. Do not 

allow fans to blow directly into fireplace. Do not place 
a blower inside burn area of firebox. Ceiling fans may 
create drafts that alter burner flame patterns. Sooting 
and improper burning will occur.

13.

  CAUTION: 

Candles, incense, oil lamps, etc. produce 

combustion  by-products  including  soot.  Vent-free 
appliances  will  not  filter  or  clean  soot  produced  by 
these types of products. In addition, the smoke and/or 
aromatics  (scents)  may  be  reburnt  in  the  vent-free 
appliance which can produce odors. It is recommended 
to minimize the use of candles, incense, etc. while the 
vent-free appliance is in operation. 

14.  An unvented gas-fired heater uses air (oxygen) from 

the room in which it is installed. Provisions for adequate 
combustion and ventilation air must be provided. See 
installation guidelines. 

15.  Keep  room  area  clear  and  free  from  combustible 

materials, gasoline and other flammable vapors and 
liquids.

16.  Unvented gas heaters are a supplemental zone heater. 

They are not intended to be a primary heating appli-
ance.

17.  Unvented  gas  heaters  emit  moisture  into  the  living 

area.  In  most  homes  of  average  construction,  this 
does  not  pose  a  problem.  In  houses  of  extremely 
tight construction, additional mechanical ventilation is 
recommended. 

IMPORTANT

Read these instructions carefully before installing or trying to operate a vent-free gas heater in this firebox. 

IMPORTANT SAFETY INFORMATION

8.  

CARBON  MONOXIDE  POISONING: 

Early  signs  of 

carbon monoxide poisoning are similar to the flu with 
headaches, dizziness and/or nausea. If you have these 
signs, obtain fresh air immediately. Have the heater 
serviced as it may not be operating properly.

9.  This unit complies with ANSI Z21.11.2 unvented heat-

ers standard.

10.  Do not install the CFX Model in a bathroom or bed-

room. 

INSTALLER

Please leave these instructions with the appliance.

OWNER

Please retain these instructions for future reference.

1.  Due  to  high  temperatures,  the  appliance  be 

located  out  of  traffic  and  away  from  furniture  and 
draperies.

2.  Children and adults should be alerted to the hazard 

of high surface temperature and should stay away 
to avoid burns or clothing ignition.

3.  Young children should be carefully supervised when 

they are in the same room with the appliance. 

4.  Do not place clothing or other flammable material on 

or near the appliance. 

5.  Any safety screen or guard removed for servicing an 

appliance, must be replaced prior to operating the 
heater.

6.  Installation and repair should be done by a qualified 

service person.

7.  To prevent malfunction and/or sooting, an unvented 

gas heater should be cleaned before use at least 
annually  by  a  professional  service  person.  More 
frequent cleaning may be required due to excessive 
lint  from  carpeting,  bedding  material,  etc.  It  is 
imperative that control compartments, burners and 
circulating air passageways be kept clean.

  Any change to this heater or its controls can be dangerous.

  Improper installation or use of the heater can cause serious injury or death 

from fire, burns, explosion or carbon monoxide poisoning.

  Do not allow fans to blow directly into the fireplace. Avoid any drafts that alter 

burner flame patterns.

  Do  not  use  a  blower  insert,  heat  exchanger  insert  or  other  accessory,  not 

approved for use with this heater where applicable.

W

ARNING

Содержание CFX24

Страница 1: ...not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas sup...

Страница 2: ...Connect the Gas 16 Check Gas Pressure 17 Electrical Wiring Milli volt 18 Connect Optional Wall Switch or Thermostat 18 Connect Remote Receiver 19 Check System Operation 19 Log Placement 20 Flame Appe...

Страница 3: ...t free gas heater in this firebox IMPORTANT SAFETY INFORMATION 8 CARBON MONOXIDE POISONING Early signs of carbon monoxide poisoning are similar to the flu with headaches dizziness and or nausea If you...

Страница 4: ...manufactured mobile home where not prohibited by local codes This appliance is only for use with the type of gas indicated on the rating plate This appliance is not convertible for use with other gase...

Страница 5: ...2PV LP Millivolt 26 000 20 000 Gas Specifications NOTE For LP models an external regulator is required to reduce supply pressure to a maximum of 13 w c ignition controls Piezo ignitor allows ignition...

Страница 6: ...ns E D C A B F G H I 1726 CFX Barrington dims H Ref CFX24 CFX32 A 11C v 299 mm 15Z v 387 mm B 19C v 502 mm 26 660 mm C 26M 683 mm 33 838 mm D 52Z x 1334 mm 61 zn 1564 mm E 44 1118 mm 50C v 1289 mm F 2...

Страница 7: ...with care CAUTION In planning the installation for the fireplace it is necessary to determine where the unit is to be installed and whether optional accessories are desired Gas supply piping should a...

Страница 8: ...d or sealed b weather striping has been added on openable windows and doors and c caulking or sealants are applied to areas such as joints around window and door frames between sole plates and floors...

Страница 9: ...fans ceiling fans return air reg isters for forced air furnaces air conditioners windows or doors Installation must provide adequate ventilation and combustion air DO NOT INSTALL THE CFX MODEL IN A B...

Страница 10: ...e inside of the appliance to any combustible adjacent wall should not be less than 9 Figure 5 2 Ceiling Clearance The ceiling must be at least 42 from the top of the firebox opening Figure 5 3 Back Wa...

Страница 11: ...ccess door 2 Remove fireplace screen frame panel by pushing screen frame panel up and out GENERAL INSTALLATION INFORMATION Figure 6 Remove Fireplace Screen Frame Panel NOTE Fireplace screen must be re...

Страница 12: ...even with the inside of the front of the mantel 8 Attach the horizontal trim piece to the mantel header Make sure the horizontal trim is centered and there is an approximate 1 4 gap between the bottom...

Страница 13: ...en the fireplace is in the proper position centered in mantel opening remove the control panel door and secure fireplace through holes provided in base to the floor of the mantel using screws provided...

Страница 14: ...e fireplace screen Refer to Page 11 Figure 6 and logs 4 Place rear firebrick panel on back wall of firebox Set bottom of panel behind the bracket tabs of the grate Figure 11 5 Place one of the side fi...

Страница 15: ...nal regulator The external regulator will reduce incoming gas pressure You must reduce incoming gas pressure to between 11 and 13 inches of water If you do not reduce incoming gas pressure burner syst...

Страница 16: ...kely to freeze A sediment trap collects moisture and contaminants and keeps them from going into the burner system gas controls If sediment trap drip leg is not installed or is installed wrong burner...

Страница 17: ...meter to the fireplace for leaks Use a solution of 50 50 water and soap solution or a gas sniffer 4 To adjust flame height turn HI LO knob to HI to get maximum pressure to burner Turn HI LO knob to L...

Страница 18: ...ll switch or thermostat At the other end connect one wire to TP TH and one wire to TH The color of the wires does not matter FP2112 wiring diagram 12 08 Optional Wall Switch Thermostat or Remote Recei...

Страница 19: ...Reading Thermostat contacts CLOSED Control Knob ON Main burner should be come ON a If the reading is more than 100 millivolts and the automatic valve still does not come on replace the control b If th...

Страница 20: ...r Pins LG588 WARNING The positioning of the logs is critical to the safe and clean operation of this heater Sooting and other problems may result if the logs are not properly and firmly positioned in...

Страница 21: ...rner Rest left end of left middle log on left front log LG589 CFX32 logs Figure 19 Log Placement CFX32 Pins Left Front Log 2 Left Middle Log 5 Right Front Log 1 Right Middle Log 4 Rear Log 3 Pins Pins...

Страница 22: ...er to Figure 22 for incorrect shape of pilot flame Figure 21 Correct Appearance of Pilot Flame FP2114 millivolt correct flame FP2114 Thermocouple for Natural Thermocouple for LP Figure 22 Incorrect Ap...

Страница 23: ...nce are treated with certain oils films or bonding agents These chemicals are not harmful but may produce annoy ing smoke and smells as they are burned off during the initial operation of the applianc...

Страница 24: ...a neighbor s phone Follow the gas supplier s in structions If you cannot reach your gas supplier call the fire department C Use only your hand to push in or turn the gas control knob Never use tools I...

Страница 25: ...control knob pushed in push in and release the piezo ignitor button to light the pilot 8 Continue pushing the control knob in for a further 60 seconds to prevent the flame detector from shut ting off...

Страница 26: ...and piezo covers and grate weldment Inspect and clean burner Remove lint or particles with vacuum brush or pipe cleaners External case should be dusted and wiped with a wet soapy cloth Annual Cleanin...

Страница 27: ...model BLOT The firebox must be connected to main power supply at time of firebox installation The blower must be installed prior to the installation of the unvented heater The electrical connections m...

Страница 28: ...ne pressure 2 Contact local gas company 3 ODS pilot is partially clogged 3 Clean ODS pilot 4 Defective Thermopile 4 Check wire connections Check output should be 500 milli volts across TH TP and TP Te...

Страница 29: ...act local gas company 2 Burner orifice is clogged 2 Clean burner or replace burner orifice Slight smoke or odor during initial operation 1 Burner orifice is clogged or damaged 1 Clean burner or replac...

Страница 30: ...Vent Free Fireplace System 20301726 REPLACEMENT PARTS Item Description Qty CFX24 CFX32 1 Assy Door Painted 1 88D0032K 88D0107K 2 Assy Screen Frame Painted 1 88D0034K 88D0109K 1 2 880011 CFX face parts...

Страница 31: ...3 2 10 8 7 11 14 13 12 5 6 880011 CFX burner parts 9 4 13 12 14 15 16 Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this appl...

Страница 32: ...13 11V0313 11V0313 11V0313 8 ODS Pilot Valve Tube 3 16 1 33D5540 49D0050 33D5540 49D0050 9 Piezo Ignitor 1 14D0503 14D0503 14D0503 14D0503 10 Piezo Wire 1 00K0632 00K0632 00K0632 00K0632 11 ODS Pilot...

Страница 33: ...33 CFX Vent Free Fireplace System 20301726...

Страница 34: ...34 CFX Vent Free Fireplace System 20301726...

Страница 35: ...uctions The Limited Lifetime Warranty will also be void if the appliance is not operated and maintained according to the operating instructions supplied with the appliance and does not extend to 1 fir...

Страница 36: ...MHSC 149 Cleveland Drive Paris Kentucky 40361 www mhsc com...