background image

12

CFX Vent Free Fireplace System

20301726

INSTALL MANTEL

1.  Place base near final position. Make sure you have access to all four (4) sides.
2.  Place sides in the approximate location on base. Align back edge of side with back of base. 

Secure joining block #1 to bottom of side using two (2) 1

Z\v

” screws. Be sure joining block is 

flush with bottom of side piece. (Do not attach to base at this time)

3.  With the aid of an assistant, and using two (2) joining block #4 and (12) 1

Z\v

” screws, secure 

header to the sides. Carefully match the moulding. 

4.  Adjust cabinet assembly so it is centered from side to side and the back of the sides are aligned 

with the back of the base.

5.  Temporarily place top on side/header assembly. Adjust sides parallel to the base and top side. 

Secure the sides to the base using two (2) 1

Z\v

” screws in each of the joining blocks.

6.  Once  the  mantel  is  assem-

bled,  temporarily  place  the 
fireplace into the mantel in or-
der to locate the trim pieces.

7.  Center  the  fireplace  in  the 

opening with the inside of the 
fireplace  trim  or  facing  even 
with the inside of the front of 
the mantel.

8.  Attach  the  horizontal  trim 

piece  to  the  mantel  header. 
Make  sure  the  horizontal 
trim  is  centered  and  there 
is  an  approximate  1/4”  gap 
between  the  bottom  of  the 
horizontal trim and the top of 
the fireplace. Secure with two 
(2) screws; one on each end 
of  the  trim  piece  in  the  pre-
drilled holes.

9.  Place the vertical trim pieces 

so the edge is about 1/4” from 
the fireplace body. Make sure 
the  joint  between  the  trim 
pieces is satisfactory. Secure 
through  joining  block  #3  into 
horizontal  trim  using  two  (2) 
screws. Attach joining block #2 to the bottom of the vertical trim. Repeat for other side.

10.  Remove fireplace and move mantel to its final position. Cut wall base moulding as necessary 

to provide adequate fit against wall.

11.  Locate  (anti-tip)  bracket  on  wall  so  the  cleat  on  the  underside  of  the 

mantel top is captured in the wall bracket and the wall bracket is screwed 
into a stud.

KT1233
wall bracket

Figure 8 - 
Wall Bracket

Joining Block #4

KT1220
assemble surround

Top

Joining 
Block #4

Right 
Side

Joining 
Block #3

Header

Joining 
Block #3

Left Side

Joining 
Block #2

Joining 
Block #2

Joining 
Block #1

Base

Joining 
Block #1

Vertical 
Trim

Vertical Trim

Horizontal Trim

KT1220

Figure 7 - 
Barrington Mantel

Содержание CFX24

Страница 1: ...not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas sup...

Страница 2: ...Connect the Gas 16 Check Gas Pressure 17 Electrical Wiring Milli volt 18 Connect Optional Wall Switch or Thermostat 18 Connect Remote Receiver 19 Check System Operation 19 Log Placement 20 Flame Appe...

Страница 3: ...t free gas heater in this firebox IMPORTANT SAFETY INFORMATION 8 CARBON MONOXIDE POISONING Early signs of carbon monoxide poisoning are similar to the flu with headaches dizziness and or nausea If you...

Страница 4: ...manufactured mobile home where not prohibited by local codes This appliance is only for use with the type of gas indicated on the rating plate This appliance is not convertible for use with other gase...

Страница 5: ...2PV LP Millivolt 26 000 20 000 Gas Specifications NOTE For LP models an external regulator is required to reduce supply pressure to a maximum of 13 w c ignition controls Piezo ignitor allows ignition...

Страница 6: ...ns E D C A B F G H I 1726 CFX Barrington dims H Ref CFX24 CFX32 A 11C v 299 mm 15Z v 387 mm B 19C v 502 mm 26 660 mm C 26M 683 mm 33 838 mm D 52Z x 1334 mm 61 zn 1564 mm E 44 1118 mm 50C v 1289 mm F 2...

Страница 7: ...with care CAUTION In planning the installation for the fireplace it is necessary to determine where the unit is to be installed and whether optional accessories are desired Gas supply piping should a...

Страница 8: ...d or sealed b weather striping has been added on openable windows and doors and c caulking or sealants are applied to areas such as joints around window and door frames between sole plates and floors...

Страница 9: ...fans ceiling fans return air reg isters for forced air furnaces air conditioners windows or doors Installation must provide adequate ventilation and combustion air DO NOT INSTALL THE CFX MODEL IN A B...

Страница 10: ...e inside of the appliance to any combustible adjacent wall should not be less than 9 Figure 5 2 Ceiling Clearance The ceiling must be at least 42 from the top of the firebox opening Figure 5 3 Back Wa...

Страница 11: ...ccess door 2 Remove fireplace screen frame panel by pushing screen frame panel up and out GENERAL INSTALLATION INFORMATION Figure 6 Remove Fireplace Screen Frame Panel NOTE Fireplace screen must be re...

Страница 12: ...even with the inside of the front of the mantel 8 Attach the horizontal trim piece to the mantel header Make sure the horizontal trim is centered and there is an approximate 1 4 gap between the bottom...

Страница 13: ...en the fireplace is in the proper position centered in mantel opening remove the control panel door and secure fireplace through holes provided in base to the floor of the mantel using screws provided...

Страница 14: ...e fireplace screen Refer to Page 11 Figure 6 and logs 4 Place rear firebrick panel on back wall of firebox Set bottom of panel behind the bracket tabs of the grate Figure 11 5 Place one of the side fi...

Страница 15: ...nal regulator The external regulator will reduce incoming gas pressure You must reduce incoming gas pressure to between 11 and 13 inches of water If you do not reduce incoming gas pressure burner syst...

Страница 16: ...kely to freeze A sediment trap collects moisture and contaminants and keeps them from going into the burner system gas controls If sediment trap drip leg is not installed or is installed wrong burner...

Страница 17: ...meter to the fireplace for leaks Use a solution of 50 50 water and soap solution or a gas sniffer 4 To adjust flame height turn HI LO knob to HI to get maximum pressure to burner Turn HI LO knob to L...

Страница 18: ...ll switch or thermostat At the other end connect one wire to TP TH and one wire to TH The color of the wires does not matter FP2112 wiring diagram 12 08 Optional Wall Switch Thermostat or Remote Recei...

Страница 19: ...Reading Thermostat contacts CLOSED Control Knob ON Main burner should be come ON a If the reading is more than 100 millivolts and the automatic valve still does not come on replace the control b If th...

Страница 20: ...r Pins LG588 WARNING The positioning of the logs is critical to the safe and clean operation of this heater Sooting and other problems may result if the logs are not properly and firmly positioned in...

Страница 21: ...rner Rest left end of left middle log on left front log LG589 CFX32 logs Figure 19 Log Placement CFX32 Pins Left Front Log 2 Left Middle Log 5 Right Front Log 1 Right Middle Log 4 Rear Log 3 Pins Pins...

Страница 22: ...er to Figure 22 for incorrect shape of pilot flame Figure 21 Correct Appearance of Pilot Flame FP2114 millivolt correct flame FP2114 Thermocouple for Natural Thermocouple for LP Figure 22 Incorrect Ap...

Страница 23: ...nce are treated with certain oils films or bonding agents These chemicals are not harmful but may produce annoy ing smoke and smells as they are burned off during the initial operation of the applianc...

Страница 24: ...a neighbor s phone Follow the gas supplier s in structions If you cannot reach your gas supplier call the fire department C Use only your hand to push in or turn the gas control knob Never use tools I...

Страница 25: ...control knob pushed in push in and release the piezo ignitor button to light the pilot 8 Continue pushing the control knob in for a further 60 seconds to prevent the flame detector from shut ting off...

Страница 26: ...and piezo covers and grate weldment Inspect and clean burner Remove lint or particles with vacuum brush or pipe cleaners External case should be dusted and wiped with a wet soapy cloth Annual Cleanin...

Страница 27: ...model BLOT The firebox must be connected to main power supply at time of firebox installation The blower must be installed prior to the installation of the unvented heater The electrical connections m...

Страница 28: ...ne pressure 2 Contact local gas company 3 ODS pilot is partially clogged 3 Clean ODS pilot 4 Defective Thermopile 4 Check wire connections Check output should be 500 milli volts across TH TP and TP Te...

Страница 29: ...act local gas company 2 Burner orifice is clogged 2 Clean burner or replace burner orifice Slight smoke or odor during initial operation 1 Burner orifice is clogged or damaged 1 Clean burner or replac...

Страница 30: ...Vent Free Fireplace System 20301726 REPLACEMENT PARTS Item Description Qty CFX24 CFX32 1 Assy Door Painted 1 88D0032K 88D0107K 2 Assy Screen Frame Painted 1 88D0034K 88D0109K 1 2 880011 CFX face parts...

Страница 31: ...3 2 10 8 7 11 14 13 12 5 6 880011 CFX burner parts 9 4 13 12 14 15 16 Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this appl...

Страница 32: ...13 11V0313 11V0313 11V0313 8 ODS Pilot Valve Tube 3 16 1 33D5540 49D0050 33D5540 49D0050 9 Piezo Ignitor 1 14D0503 14D0503 14D0503 14D0503 10 Piezo Wire 1 00K0632 00K0632 00K0632 00K0632 11 ODS Pilot...

Страница 33: ...33 CFX Vent Free Fireplace System 20301726...

Страница 34: ...34 CFX Vent Free Fireplace System 20301726...

Страница 35: ...uctions The Limited Lifetime Warranty will also be void if the appliance is not operated and maintained according to the operating instructions supplied with the appliance and does not extend to 1 fir...

Страница 36: ...MHSC 149 Cleveland Drive Paris Kentucky 40361 www mhsc com...