background image

2

Important Information .......................................................................................................................2-4
Appliance System Components ................................................................. ............... ..5
Clearances ........................................................................... ............................................6
Installation Preparation ...................................................................................................7-8
Fireplace and Venting Installation ..................................................................................................9
Venting Requirements ......... ..................................................................................... ..........10
Gas Supply Connections .............................. .................................................................11
Electrical Wiring .....................................................................................................................................11
Electronic Ignition .... ........................ ............................................................................12
Fireplace Setup ....................................................................................................................................13
Operating Instructions .....................................................................................................................14-15
Maintenance Instructions ................................................................................................................15-16
Outside Combustion Air Precautions and Recommendations .............................................................17
Combustion Air Assembly .....................................................................................................................18
Troubleshooting .....................................................................................................................................19
Repair Parts List...................................................................................................................................20

C

ONGRATULATIONS

!

You have chosen the finest B-vent gas fireplace system available.  Your fireplace has been designed for
years of decorative viewing enjoyment.  Please take time to read this entire manual before installing or
operating your system.

T

ABLE

 

OF

  C

ONTENTS

L

ISTING

 

AND

 C

ODE

 A

PPROVALS

U.S. and Canada Certification

The BBV400NV Series Gas Appliance has been tested in accordance with the ANSI Z21.50-
1998/CSA M2.22-M98 Standard for Vented Gas Fireplaces and have been LISTED by OMNI-
Test Laboratories, Inc. for installation and operation as described in these Installation and
Operating Instructions.  All components are UL, AGA, CGA, or CSA safety certified.

Local Codes

Check with your local building code agency prior to installing this appliance to ensure
compliance with local codes, including the need for permits and follow-up inspections.  This
installation must conform with local codes or, in the absence of local codes, in the USA with
the National Fuel Gas Code, ANSI Z223.1-latest edition.

53D9015. Rev 1 03/03

Содержание BBV400NE

Страница 1: ...ODILY INJURY OR DEATH DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS AND LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE WHAT TO DO IF YOU SMELL GAS DO NOT TRY TO LIGHT ANY APPLIANCE DO NOT TOUCH ANY ELECTRICAL SWITCH DO NOT USE ANY PHONE IN YOUR BUILDING IMMEDIATELY CALL YOUR GAS SUPPLIER FROM A NEIGHBOR S PHONE FOLLOW THE GAS SUPPLIER S INSTRUCTIONS IF YOU CANNOT REACH YOUR GAS SU...

Страница 2: ...entire manual before installing or operating your system TABLE OF CONTENTS LISTING AND CODE APPROVALS U S and Canada Certification The BBV400NV Series Gas Appliance has been tested in accordance with the ANSI Z21 50 1998 CSA M2 22 M98 Standard for Vented Gas Fireplaces and have been LISTED by OMNI Test Laboratories Inc for installation and operation as described in these Installation and Operating...

Страница 3: ...ater column Notice This appliance operates with a yellow smoky flame When properly adjusted according to these instructions small amounts of carbon soot will be deposited on the outlet section of the air terminal and possibly on surrounding structure If not properly adjusted and operated according to these instructions carbon soot will accumulate in larger quantities on the air terminal and surrou...

Страница 4: ...ulating air passageways of the fireplace and venting system are kept clean The fireplace and its venting system should be inspected before use and at least annually by a qualified service person More frequent cleaning may be required due to excessive lint from carpeting bedding material etc The fireplace area must be kept clear and free from combustible materials gasoline and other flammable vapor...

Страница 5: ... of the components that may safely be used with this appliance are listed below BBV400NV Standing Pilot Natural Gas BBV400NE Electronic Ignition Natural Gas Field convertible to propane gas GD36PB Polished Brass Glass Door GD36B Black Finish Glass Door Shown below CK35E LP Conversion Kit for Electronic Ignition Model CK35L LP Conversion Kit for Standing Pilot Model RC2 Hand Held Remote Control GFW...

Страница 6: ...her than wood flooring the fireplace shall be installed on a metal or wood panel extending the full width and depth of the appliance Adequate combustion and ventilation air must be provided Provide adequate accessibility clearance for servicing and operating the fireplace Never obstruct the front opening of the fireplace FIGURE 1 GAS LINE GAS LINE KNOCKOUT KNOCKOUT JUNCTION BOX JUNCTION BOX KNOCKO...

Страница 7: ...rical wiring requirements Framing and finishing details Whether optional accessories devices such as a fan wall switch or remote control are desired HIGH ALTITUDE INSTALLATION For U S installation units are tested and approved for elevations from 0 2000 feet When installing this unit at an elevation above 2000 feet United States codes require a decrease of the input rating by changing the existing...

Страница 8: ...HE ENCLOSURE Figure 3 shows a typical framing of this appliance assuming combustible materials are used All required clearances shown in Figures 1 and 3 to combustibles around the appliance must be adhered to Any framing at the back and sides of the appliance must be outside the spacers Any framing on top of the appliance must be above the top spacers Fireplace framing can be built before or after...

Страница 9: ...SPECIFIED BY VENT SPECIFIED BY VENT SUPPORT SUPPORT LISTED CEILING LISTED CEILING GAS VENT GAS VENT 4 TYPE B 4 TYPE B WALL WALL 1 2 AIR SPACE TO SIDES 1 2 AIR SPACE TO SIDES AND REAR OF FIREPLACE AND REAR OF FIREPLACE GAS APPLIANCE GAS APPLIANCE FLOOR FLOOR FIREPLACE AND VENTING INSTALLATION 9 FIGURE 3 12 MIN FROM FIREPLACE OPENING TO BOTTOM OF COMBUSTIBLE MANTEL 12 MAX 3 1 2 MIN NON COMBUSTIBLE M...

Страница 10: ...or in the absence of local codes according to the National Fuel Gas Code Z223 1 Latest edition by a licensed or otherwise qualifed installer Your local gas company should have copies of the National Fuel Code Z223 1 or other installation codes applicable to your area Venting requirements and accepted methods vary greatly depending on the particular installation It is impossible to thoroughly defin...

Страница 11: ...petroleum gases A 1 8 inch 3 mm N P T plugged tapping accessible for test gauge connection should be provided in the gas supply line leading to the unit s shutoff valve 4 After gas piping installation is complete carefully check all piping connections for gas leaks using a leak detecting solution Caution The gas valve can be damaged if subjected to more than psig during pressure testing of the gas...

Страница 12: ...COMMON COMMON LINE LINE 120V 60 Hz 120V 60 Hz POWER SUPPLY POWER SUPPLY TRANSFORMER TRANSFORMER SWITCH SWITCH IGNITION WIRE IGNITION WIRE TAP TAP PRESSURE PRESSURE OUTLET OUTLET ELECTRONIC CONTROL ELECTRONIC CONTROL CONTROL ADJUST SCREW CONTROL ADJUST SCREW INLET PRESSURE INLET PRESSURE IN IN GAS CONTROL VALVE GAS CONTROL VALVE GAS SUPPLY IN GAS SUPPLY IN ON ON OFF OFF MV MV PV PV PV PV MV MV SPAR...

Страница 13: ...arth around the ember material Warning Improper log placement may result in production of increased quanities of poisonous carbon monoxide and soot 3 Install the glass door assembly supplied separately from this package The glass door is installed by inserting the top two 2 pins into the receiving holes above the fireplace opening and then inserting two 2 pins into the bottom Use care not to bump ...

Страница 14: ...avier than air and will settle on the floor loor WHAT TO DO IF YOU SMELL GAS WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not try to light any appliance Do not touch any electrical switch do not use any phone in your buil Do not touch any electrical switch do not use any phone in your building ding Immediately call your gas supplier from a neighbor s phone Follow th Immediately...

Страница 15: ...ctions for tightness and to make sure there is no blockage at the termination no unusual corrosion or other damage 4 The appliance area must be kept clear and free from combustible materials gasoline and other flammable vapors and liquids FIGURE 7 6 Wait five 5 minutes to clear out any gas If you then smell gas STOP Follow the instructions in the warning on page 14 If you do not smell gas go to ne...

Страница 16: ...lete assembly as supplied by the manufacturer See the Repair Parts List 8 Never attempt to replace the glass panel with another piece of glass or use any other substitute materials 9 Never attempt to operate this appliance with a broken glass door 10 When removing or replacing the glass door for cleaning or inspection care must be taken not to abuse the glass panel by striking slamming shut or scr...

Страница 17: ...h is not likely to be accidentally blocked in any manner The assembly should be located above the snow line to prevent blockage by snow accumulation 3 The combustion air inlet assembly should never be mounted in a garage or storage area where combustible fumes such as gasoline might be drawn into the fireplace 4 Combustion air can be drawn from the crawl space under a house when an adequate supply...

Страница 18: ...starting collar 4 inch into the hole on the left side of the fireplace Fasten it in place with the four sheet metal screws provided 3 Cut a 6 inch diameter opening for model OAC 4 in the outside wall covering where the outside vent is to be located 4 Select and cut a piece of duct sufficient length to attach to the fireplace and protrude at least three inches beyond the face of the wall to which t...

Страница 19: ...e Pressure regulator set too high Defective regulator on heater Reset using manometer Replace Burner orifice too large Replace with correct size Noisy pilot Burr in orifice Remove burr or replace Reduce pilot gas Clogged vent system Clogged burner ports Misaligned orifice Too little primary air Clean air intake to burners Insufficient primary air Blocked venting Clean Defective auto valve Replace ...

Страница 20: ...0A 073391A 073391A 057958A 057958A 057955A 057955A 057956A 057956A 060874A 060874A 053297A 053297A 053298A 053298A 052139A Description Description Glass Door Brass Glass Door Black Log Set Burner Orifice Natural 45 Orfice LP 55 Pilot Standing Piiot Natural Pilot Standing Pilot LP Piezo Ignitor Gas Valve Standing Pilot Natural Gas Valve Standing Pilot LP Pilot Electronic Ignitor Gas Valve Electroni...

Страница 21: ...NOTES 21 53D9015 Rev 1 03 03 ...

Страница 22: ...22 NOTES 53D9015 Rev 1 03 03 ...

Страница 23: ...NOTES 23 53D9015 Rev 1 03 03 ...

Страница 24: ...ATTENTION APPLIANCE INSTALLER PLEASE RETURN THESE OPERATING AND INSTALLATION INSTRUCTIONS TO THE APPLIANCE FOR CONSUMER USE 53D9015 REV 1 03 03 ...

Отзывы: