4.   Never install the fireplace 

    •  in a recreational vehicle

    •  where curtains, furniture, clothing, or other flammable 

objects are less than 42" from the front, top, or sides 

of the fireplace

    •  in high traffic areas

    •  in windy or drafty areas 
5.  This fireplace reaches high temperatures. Keep children 

and adults away from hot surfaces to avoid burns or cloth-

ing ignition. Fireplace will remain hot for a time after 

shutdown. Allow surfaces to cool before touching. 

6.  Carefully supervise young children when they are in the 

room with fireplace. 

7.  Do not modify fireplace under any circumstances. Any 

parts removed for servicing must be replaced prior to 

operating fireplace. 

8.  Turn fireplace off and let cool before servicing, install-

ing, or repairing. Only a qualified service person should 

install, service, or repair the fireplace. Have burner system 

inspected annually by a qualified service person. 

9.  You must keep control compartments, burners, and cir-

culating air passages clean. More frequent cleaning may 

be needed due to excessive lint and dust from carpeting, 

bedding material, pet hair, etc. Turn off the gas valve and 

pilot light before cleaning fireplace. 

10. Have venting system inspected annually by a qualified 

service person. If needed, have venting system cleaned 

or repaired. See 

Cleaning and Maintenance

, page 32. 

11.  Keep the area around your fireplace clear of combustible 

materials, gasoline, and other flammable vapor and liq-

uids. Do not run fireplace where these are used or stored. 

Do not place items such as clothing or decorations on or 

around fireplace. 

     

INSTALLER

     

Please leave these instructions with the 

app

liance

.

OWNER

Please retain these instructions for future reference.

IMPORTANT SAFETY INFORMATION

This fireplace is a decorative gas appliance. This fireplace 

must be properly installed by a qualified service person. 

CARBON  MONOXIDE  POISONING:

 

Early  signs  of 

carbon monoxide poisoning are similar to the flu with head-

aches, dizziness and/or nausea. If you have these signs, the 

fireplace may not have been installed properly. Get fresh air 

at once! Have the fireplace inspected and serviced by a quali-

fied service person. Some people are more affected by carbon 

monoxide than others. These include pregnant women, people 

with heart or lung disease or anemia, those under the influence 

of alcohol, and those at high altitudes. 
Propane/LP gas and natural gas are both odorless. An odor-

making agent is added to each of these gases. The odor helps 

you detect a gas leak. However, the odor added to these gases 

can fade. Gas may be present even though no odor exists.
Make certain you read and understand all warnings. Keep 

this manual for reference. It is your guide to safe and proper 

operation of this fireplace.
1.  This appliance is only for use with the type of gas indi-

cated on the rating plate. This appliance is not convertible 

for use with other gases unless a certified kit is used. 

2.  For propane/LP fireplace, do not place propane/LP supply 

tank(s) inside any structure. Locate propane/LP supply 

tank(s) outdoors. To prevent performance problems, do not 

use propane/LP fuel tank of less than 100 lbs. capacity. 

3.  If you smell gas

    •  shut off gas supply.

    •  do not try to light any appliance.

    •  do not touch any electrical switch; do not use any 

phone in your building .

    •  immediately call your gas supplier from a neighborʼs 

phone. Follow the gas supplierʼs instructions.

Continued on page 4

•  Read this owner’s manual carefully and completely before trying to assemble, operate, 

or service this fireplace. 

•  Any change to this fireplace or its controls can be dangerous.
•  Improper installation or use of this fireplace can cause serious injury or death from 

fire, burns, explosions, electrical shock and carbon monoxide poisoning.

W

ARNING

Содержание B-VENT BBV400

Страница 1: ...ed installer service agency or the gas supplier WARNING Improper installation adjustment alteration servicesormaintenancecancauseinjuryor property damage Refer to this manual For assistance or additio...

Страница 2: ...ition Wiring 22 Final Installation 23 Rock Wool Placement 23 Log Placement 23 Lava Rock and Ember Placement 23 Operating Instructions 24 What To Do If You Smell Gas 24 Lighting Pilot for the First Tim...

Страница 3: ...replace must be properly installed by a quali ed service person CARBON MONOXIDE POISONING Early signs of carbon monoxide poisoning are similar to the u with head aches dizziness and or nausea If you h...

Страница 4: ...se with a thermostat 22 This appliance must be installed with draft hood in same atmospheric pressure zone as the combustion air inlet to the appliance 22 For Massachusetts Residents Only This product...

Страница 5: ...lation code ANSI Z223 1 NFPA 54 in the USA CAN CGA B149 in Canada The appliance must be properly connected to a venting system The appliance is not approved for closet or recessed installations PRODUC...

Страница 6: ...ot install any unit with damaged incomplete or substitute parts Check your packing list to verify that all listed parts have been received You should have the following Fireplace Firebox and Burner Sy...

Страница 7: ...or raised on a platform of an appropriate height When the rebox is installed directly on carpeting tile or other combustible material other than wood ooring the rebox shall be installed on a metal or...

Страница 8: ...ir Kit 23 16 1 2 or 5 8 Drywall Spacers 71 4 Electrical Gas Access 141 2 Framing Dimension D Framing Dimension B C TOP VIEW FRONT VIEW SIDE VIEW 40 163 4 401 4 Framing Dimension PRE INSTALLATION INFOR...

Страница 9: ...nsion B C TOP VIEW FRONT VIEW SIDE VIEW 40 23 16 PRE INSTALLATION INFORMATION Figure 4 SBV400 and SBV500 Dimensions FIREPLACE DIMENSIONS SBV400 and SBV500 SBV400 SBV500 A 2413 16 3013 16 B 36 42 C 40...

Страница 10: ...woodwork and windows Minimum clearances to combustibles must be maintained This replace may be installed along a wall across a corner or use an exterior chase Location should be out of high traf c are...

Страница 11: ...uctions exactly can create a re hazard The appliance cannot be installed on a carpet tile or other combustible material other than wood ooring If installed on carpet or vinyl ooring the appliance shal...

Страница 12: ...r Use four 4 screws to attach replace to framing The side brackets are adjustable from 1 2 to 5 8 to accommodate different thickness of material SECURING FIREPLACE TO FLOOR OR FRAMING Figure 6 Securin...

Страница 13: ...n on rooftops Be aware of electrical wiring locations in walls and ceilings The following actions will void the warranty on your venting system Installation of any damaged venting component Unauthoriz...

Страница 14: ...been listed by a nationally recognized testing agency See B Vent Pipe Sizing chart for proper elbow offset runs Locate chimney center line dimension from a combustible back wall See Figures 3 and 4 p...

Страница 15: ...you would the outside walls of your home This is especially important in cold climates Insulation should be considered a combustible material Maintain proper clearances to all combustible materials NO...

Страница 16: ...ocation Make sure the location cannot be accidentally blocked Locate assembly above snow line to prevent snow from blocking assembly 3 Never mount combustion air inlet assembly in garage or storage ar...

Страница 17: ...duct with a standard pocket knife See Figure 14 DO NOT remove the cover if the outside air will not be connected WARNING Figure 13 Attaching Outside Air Starting Collar to Left Side of Fireplace Figur...

Страница 18: ...ITEMS NEEDED Before installing make sure you have the items listed below External regulator supplied by installer Tee joint Piping check local codes Pipe wrench Sealant resistant to propane LP gas Tes...

Страница 19: ...ap Approved Flexible Gas Line UL CSA Design Certi ed Equipment Shutoff Valve with 1 8 NPT Tap Sediment Trap Drip Leg Natural Gas From Gas Meter 5 W C to 10 5 W C Pressure Propane LP From External Regu...

Страница 20: ...e gas meter to the replace for leaks Use a solution of 50 50 water and soap or a gas sniffer 4 To adjust ame height turn HI LO knob to HI to get maximum pressure to burner Turn HI LO knob to LO to get...

Страница 21: ...al code Figure 19 Wiring Diagram for Wall Switch ELECTRICAL INSTALLATION ELECTRICAL WIRING Electrical connections should only be performed by a quali ed licensed electrician Main power must be off whe...

Страница 22: ...TIONAL DC REMOTE SYSTEMS These instructions replace the section entitled Hearth Mount in the Millivolt hand held remote instructions supplied with the remote 1 Plug in remote connector wire to remote...

Страница 23: ...ertical Grate Bar Right Vertical Grate Bar Center Vertical Grate Bar Log Mounting Pins ROCK WOOL PLACEMENT 1 Place rock wool on burner to provide glowing embers For best results pull the rock wool apa...

Страница 24: ...air may result in a re or explosion D Do not use this appliance if any part of it has been under water Immediately call a quali ed service tech nician to inspect the appliance and to replace any part...

Страница 25: ...it is possible to start the lighting operation The gas control knob is designed to be operated by hand DO NOT use any tools during this operation Damaged knobs may result in serious injury WARNING 1...

Страница 26: ...n burner without using the gas valve knob Make sure the button is in the ON position to light the main burner See Figure 24 LIGHTING THE BURNER Depress and turn the knob counterclockwise to the ON pos...

Страница 27: ...hand B BEFORE OPERATING smell all around the appli ance area for gas Be sure to smell next to the oor because some gas is heavier than air and will settle on the oor WHAT TO DO IF YOU SMELL GAS Turn o...

Страница 28: ...patterns to vary Figure 30 Burner Flame Appearance CLEANING AND MAINTENANCE BURNER PILOT AND CONTROL COMPARTMENT Keep the control compartment logs and burner areas surrounding the logs clean by vacuu...

Страница 29: ...ogs with a brush attachment If logs must be removed for cleaning handle carefully by holding gently at each end Gloves are recommended to prevent skin irritation from ceramic bers If skin becomes irri...

Страница 30: ...30 62D4036 1 2 3 4a 4b 4c 5 7 6 ILLUSTRATED PARTS LISTS FIREBOX COMPONENTS...

Страница 31: ...16 62D2016 4c Right Refractory Floor 1 n a 62D1017 62D2017 Optional Field Installed Accessories 5 Firebrick Assembly 1 FBBV400W n a n a 6 Outside Air Kit 1 OAC4 OAC4 OAC4 7 Black Glass Door Assembly 1...

Страница 32: ...32 62D4036 ILLUSTRATED PARTS LISTS 1 2 3 4 5 6 7 8 10 12 13 STANDING PILOT MILLIVOLT CONTROL 2T 2I 2C 9 11...

Страница 33: ...48 41D0048 41D0048 41D0048 41D0048 6 Piezo Igniter 1 14D0503 14D0503 14D0503 14D0503 14D0503 14D0503 7 Injector 1 62D3006 62D3005 62D3004 20H3143 62D3003 59D0094 8 Burner Assembly 1 54D0200 54D0200 54...

Страница 34: ...34 62D4036 ILLUSTRATED PARTS LISTS 1 2 3 4 5 6 7 9 ELECTRONIC IGNITION 8 10 11 12...

Страница 35: ...23D6046 23D6046 23D6046 23D6046 23D6046 23D6046 5 Rocker Switch 1 41D0048 41D0048 41D0048 41D0048 41D0048 41D0048 6 Injector 1 62D3006 62D3005 62D3004 20H3143 62D3003 59D0094 7 Burner Assembly 1 54D02...

Страница 36: ...ntrol or wire B Pilot ame too small C Defective or malfunctioning ther mopile D Defective valve A Check switch and wire for proper connection Place jumper wires across terminals of switch If burner co...

Страница 37: ...locked B Check electrical connections between module and pilot operator on gas control C Check for 24VAC across PV MVPV terminals If voltage is correct replace gas control If voltage is not correct re...

Страница 38: ...Replace with proper size H Construct a single venting system for each appliance 3 Poor draft due to termination cap A Cap obstructed by a decorative enclosure B Cap is crushed damaged or miss ing A R...

Страница 39: ...ve finished grade in the area of the venting including but not limited to decks and porches the following requirements shall be satisfied 1 INSTALLATION OF CARBON MONOXIDE DETECTORS At the time of ins...

Страница 40: ...d in whole or in part for residential purposes c MANUFACTURER REQUIREMENTS GAS EQUIPMENT VENTING SYSTEM PROVIDED When the manu facturer of Product Approved side wall horizontally vented gas equipment...

Страница 41: ...62D4036 39 NOTES...

Страница 42: ...th the installation instructions The Limited Lifetime Warranty will also be void if the appliance is not operated and maintained according to the operating instructions supplied with the appliance and...

Отзывы: