MONDEX Kalla 6.6 Скачать руководство пользователя страница 13

13

Installation and Operating Instructions  Kalla

10. Heater control and operation

normal start:

 Select the operating 

time with the control buttons.

The operating time is displayed in light bars.  

One bar equals 30 min. The maximum  

operating time is 4h.

Quick start:

 Press the quick start button. 

The heater will remain on for two hours.

temperature control:

 Set the desired 

temperature with the control buttons. 

One light bar affects the temperature  

by approximately 5°C.

Heater start-up:

 When the operating time 

and temperature have been set, switch on the 

heater from the power switch. NOTE! If the 

power switch is not pressed, the controller lights will 

keep blinking. NOTE! The heater will remember the 

previous temperature setting.

timer function:

 You can set the heater to switch on in 

30 min. – 8 hours. After that, the heater will remain 

on for 4 hours.

•  Keep the operating time controller depressed 

until the red lights turn off.

•  After this, the light bars will turn blue and each 

bar represents a period of 30 min.

•  Select the desired temperature for the sauna with 

the temperature control buttons.

•  You can switch off the heater at any time  

by pressing the power switch.

First time use of the heater (heater 

calibration)

Ensure that the main switch on the side of the heater 

is in the “I” position. Set the temperature to two LED 

lights from the bottom. Press the quick start button 

(

2h

). Switch the heater on by pressing the power 

switch in the upper left-hand corner. When 2 hours 

have elapsed or the blue LED light at the lower right-

The heater is operated by 

adjusting its operating time 

and temperature, and then by 

switching the heater on from the 

power switch.

Overheating protector

The overheating protector reset button is located 

above the heater’s main power switch under a 

protective cap. Twist the cap to open. The red reset 

button located under the cap is 3.5 mm thick.

hand corner has turned off, the heater calibration 

is complete. Do not open the sauna door during 

the calibration. During the calibration, the heater 

“teaches itself” to heat up optimally according to the 

size of the sauna. The heater can be used normally 

after the calibration. NOTE! The heater must be filled 

with heater stones before the first use (calibration). 

Resetting the heater

Switch off the heater from the main switch located 

on the lower right-hand side of the heater. Keep 

the temperature control 

+

 and 

 buttons depressed. 

Switch the main switch of the heater on again 

while keeping the 

+

 and 

 buttons depressed. The 

heater is now ready for calibration. For calibration 

instructions, see “First-time use of the heater 

(heater calibration)”. 

Error codes

If the heater encounters an error, the electronics 

will turn off the resistors and indicate the controller 

faults with blue lights as follows:

4th light from bottom:  

relay fault

3rd light from bottom:  

short circuit of the 

thermal sensor

2nd light from bottom:  

contact failure of the 

thermal sensor

1st light from bottom:  

calibration status

Operating time 

adjustment

Power switch

Operating time

Temperature

Temperature 

control

Quick start

Содержание Kalla 6.6

Страница 1: ...Installation and Operating Instructions The Kalla heater 12 2017 ...

Страница 2: ...n using the heater 7 First heating 7 Sauna room 7 Temperature control 7 Heating time 7 Water thrown on heater 7 Sauna room structure 8 7 Wall mount installation 9 8 Installation instructions 10 Installation of external control and sensor 11 9 Wiring diagram 12 Controller card wiring heater 12 Controller card wiring controller 12 10 Heater control and operation 13 First time use of the heater calib...

Страница 3: ...able for use in a family sauna one 1 heater per sauna room Retain the installation and operating instructions for further reference Always check the adequacy of the fire protection distances Failure to observe the wiring instructions may result in a risk of fire Always check the sauna room before switching the heater on Always check that the controller has switched the heater off after the set tim...

Страница 4: ...er visually If you notice any discrepancies please contact the store where you purchased the heater or e mail info mondex fi 3 The heater is installed so that it leans against a wall using the bracket provided see the dimensions on page 9 4 To facilitate installation adjust the heater s feet so that they extend out 8 9 cm 2 Kalla heater 3 Heater assembly and installation Kalla heater ...

Страница 5: ...ng the stones in this way until all of them have been placed Note Ensure that the resistors do not touch the heater s net frame anywhere There must always be a stone between a resistor and the frame Note Do not remove the bands around the resistors If there are two bands one of them is located at approximately 20 cm from the bottom and another at approximately 10 15 from the top They keep the resi...

Страница 6: ...00 V 3N Connecting cable 5 x 1 5 mm 5 x 2 5 mm Fuse 3 x 10 A 3 x 16 A 4 Technical specifications Table 4 1 Type A B C D Volume Kalla 6 6 100 850 100 1900 6 9 m Kalla 9 0 120 870 100 1900 8 15 m Type Width Depth Height Kalla 6 6 350 304 1030 Kalla 9 0 350 304 1030 Type Stone amount kg Kalla 6 6 80 Kalla 9 0 80 Table 4 3 Table 4 2 Table 4 4 Minimum distances to inflammable material mm D C C A B ...

Страница 7: ...una room before switching the heater on Always make sure that the timer has switched the power off after the set time period Temperature control The temperature is adjusted from the control panel see page 14 The actual heating time depends on the dimensions structure and thermal insulation of the sauna The temperature in the sauna room can be maintained at the desired level with the thermostat If ...

Страница 8: ...nd on timber surfaces by 1 5 m3 The factor for glass surfaces glass walls doors and uninsulated stone surfaces is also 1 2 m3 per square metre In borderline cases you should choose a heater with higher power The sauna needs efficient ventilation for a good oxygen level and a sufficient amount of fresh air The air in the sauna needs to change at least 6 times per hour For a sauna with an electric h...

Страница 9: ...e adhered to the recommended safety distances between the heater and any inflammable materials on the sides and underneath the heater are met Floor Keep in mind that the adjustable feet may add to the total height of the heater 7 Wall mount installation 130 150 810 401 5 327 5 51 ...

Страница 10: ...ion and Operating Instructions Kalla 8 Installation instructions Supply cable 5 x 1 5 mm2 5 x 2 5 mm2 Sensor Switch board Controller Sauna Changing room Utility room Controller ca 250 mm ca 250 mm Sensor max 99 cm ...

Страница 11: ... drop of silicone adhesive The length of the sensor cable is 6 m Cut the excess wire and connect the other end to the heater Ensure that a minimum of 7 mm of the end of the wire is stripped to ensure a proper contact The wall mounting plate is either mounted to the wall using three screws or affixed to the bottom of the mounting box The mounting plate is covered first with a cover plate and finall...

Страница 12: ...lla 9 Wiring diagram Quick connector Controller card wiring heater Controller card wiring controller To the controller To the overheating protector To the temperature sensor White Grey Green Blue Red White White Black Black OVERHEATING PROTECTION ...

Страница 13: ...n the upper left hand corner When 2 hours have elapsed or the blue LED light at the lower right The heater is operated by adjusting its operating time and temperature and then by switching the heater on from the power switch Overheating protector The overheating protector reset button is located above the heater s main power switch under a protective cap Twist the cap to open The red reset button ...

Страница 14: ...is switched on again If necessary contact the dealer or manufacturer Warnings Due to a risk of fire do not use the sauna to dry clothes or laundry Exercise caution with a hot heater since the heater stones and metal parts become very hot and can cause burns The water steam rising from the heater is hot and can cause burns Children disabled and ill persons who are using the sauna should be supervis...

Страница 15: ...and spare parts In case of a fault that cannot be solved please contact the store where you purchased the heater or email info mondex fi Spare parts can be purchased from Mondex distributors and the manufacturer When purchasing spare parts please refer to the name power serial number and manufacturing date of the heater to ensure you receive the correct parts Natural stone as material Small pebble...

Страница 16: ...l support info mondex fi Premec Oy Kettukallionkatu 4 84100 Ylivieska Finland info mondex fi www mondex fi Heater maintenance history We recommend changing the heater stones at one year intervals Date Procedure ...

Отзывы: