background image

OWNER'S
MANUAL

TSP SERIES

Self Priming Trash Pumps

PumpBiz.com 

200162R3   0402

SAFETY  WARNINGS

BEFORE  OPERATING  OR
INSTALLING  THIS  PUMP,  READ
THIS  MANUAL  AND  FOLLOW
ALL  SAFETY  RULES  AND
OPERATING  INSTRUCTIONS.

 CAUTION

DO NOT OPERATE THIS PUMP DRY!

Review instructions before operating.

Wear ear protection to reduce objectionable noise.

__________________________________________________

 WARNING

Turn off power before servicing.

If fuel is spilled, avoid creating any source of ignition until the
fuel vapors have been cleaned up and removed.

APPLICATION

This pump is suitable for installations where the vertical distance
from the pump to the water level does not exceed 25 ft.  In off-set

PERFORMANCE

installations, friction losses in the suction pipe must be taken into
consideration.

Total Head in Feet

Pump Pump

Solids

30

40

50

60

70

80

90

Model

Size

Handling

Capacity in U.S. Gallons per Minute

TSP 2 2” x 2”

1 1/8”

198 194 180 145

110

75

40

TSP 3 3” x 3”

1 1/2”

318 265 172

98

42

TSP 4 4” x 4”

2”

616 500 400 280 190 120

45

BASED ON 5’ SUCTION LIFT.

NOTE:

  This trash pump can handle pumping stones, leaves,

mud and other debris of sizes up to the listed solids handling for
the pump and up to 25% of the flow by volume.

Total Head in Metres

Pump

9

12

15

18.5 21.5 23.5 27.5

Model

Capacity in Litres per Minute

TSP 2

750

735 680

550 415

285 150

TSP 3

1205 1005 650

370 160

TSP 4

2330 1890 1515 1060 720

455 170

 SAFETY

CAREFULLY  READ  THESE  SAFETY
MESSAGES  IN  THIS  MANUAL  AND
ON  PUMP.

Отзывы: