NICE5000 User Manual 5 System Commissioning and Functions
- 87 -
2. The riding comfort during running may be influenced if the brake arm is installed too
tightly or released incompletely.
3. If the car weight is unbalanced, it will cause uneven stress of the guide shoes that
connect the car and the guide rail. As a result, the guide shoes will rub with the guide
rail during running, affecting the riding comfort.
4. For asynchronous motor, abrasion or improper installation of the gearbox may also
affect the riding comfort.
5. Resonance is an inherent character of a physical system, related to the material
and quality of system components. If you are sure that the oscillation is caused by
resonance, reduce the resonance by increasing or decreasing the car weight or
counterweight and adding resonance absorbers at connections of the components (for
example, place rubber blanket under the motor).
5.4 Password Setting
The NICE5000 provides the parameter password protection function. Here gives an
example of changing the password into 12345 ( indicates the blinking digit), as shown in
the following figure.
Figure 5-4 Example of changing the password
F0
0.000
Status parameter
PRG
(default display)
FP
PRG
FP-00
00000
PRG
PRG
ENTER
To save the
setting
ENTER
ENTER
PRG
FP-01
12345
If there is a blinking digit, press
/ / to modify the digit.
• After you set the user password (set FP-00 to a non-zero value), the system requires
user password authentication (the system displays "------") when you press PRG. In this
case, you can modify the function code parameters only after entering the password
correctly.
• For factory parameters (group FF), you also need to enter the factory password.
• Do not try to modify the factory parameters. If these parameters are set improperly, the
system may be unstable or abnormal.
• In the password protection unlocked state, you can change the password at any time.
The last input number will be the user password.
• If you want to disable the password protection function, enter the correct password
and then set FP-00 to 0. If FP-00 is a non-zero value at power-on, the parameters are
protected by the password.
Содержание NICE 5000
Страница 1: ...5000 5000 User Manual 5000 Integrated Elevator Controller Data code 19010314...
Страница 15: ......
Страница 16: ...1 Safety Information and Precautions...
Страница 23: ...1 Safety Information and Precautions NICE5000 User Manual 22...
Страница 24: ...2 Product Information...
Страница 34: ...3 Mechanical and Electrical Installation...
Страница 71: ...4 Use of the Commissioning Tools...
Страница 79: ...5 System Commissioning and Functions...
Страница 99: ...6 Function Code Table...
Страница 130: ...6 Function Code Table NICE5000 User Manual 128...
Страница 131: ...7 Description of Function Codes...
Страница 201: ...8 Troubleshooting...
Страница 220: ...8 Troubleshooting NICE5000 User Manual 218...
Страница 221: ...9 EMC...
Страница 230: ...9 EMC NICE5000 User Manual 228...
Страница 233: ...5000 5000 User Manual 5000 Integrated Elevator Controller Data code 19010314...