background image

 

 

9.0  CHARGING 

Slide  the  Power  switch  (8)  to  the 

Off/Charge

  position  and  plug  in  the 

charger.  The 

Power

 LED (4) will blink red while the unit is fast charging.  

The 

Power

 LED will blink amber when slow (trickle) charging.  It will be 

solid amber when the batteries are fully charged.  

Note: 

If  the  charger  is  plugged  in  when  the  Power  switch  is  the  on 
position, the batteries will be trickle charged during operation. 

CAUTION:  Use  only  the  supplied  PR-Universal  charger  with 

the sensor. 

10.0  SPECIFICATIONS 

Note:  

Product specifications are subject to change without notice. 

10.1  Laser Specifications 

Classification:

 

Class 3R (per IEC 60825-1 Edition 3 2014) 

 

Complies  with  21CFR  1040.10  and  1040.11  except  for  deviations 
pursuant to Laser Notice No. 50, date June 24, 2007. 

Maximum Laser Output:

  <5mW 

Pulse Duration:

 

Continuous 

Laser Wavelength:

 

650 nm 

Beam Divergence:

 

< 0.5 mrad   

Beam Diameter:

 

4 x 7 mm typical at 2 meters 

Laser Diode Life:

 

8,000 hours MTBF (1 year warranty) 

Laser  is  on  when  this  indicator  is 
illuminated. 
AVOID EXPOSURE 
LASER  RADIATION  IS  EMITTED 
FROM THIS APERTURE. 

Содержание SLS-115

Страница 1: ...SLS 115 230 Smart Laser Sensor 15 Columbia Drive Amherst NH 03031 USA Phone 603 883 3390 Fax 603 886 3300 E mail support monarchinstrument com Website www monarchinstrument com...

Страница 2: ...specifications stated This instrument is not user serviceable For technical assistance contact the sales organization from which you purchased the product WARNING Use only the PR Universal charger su...

Страница 3: ...0 0 SPECIFICATIONS 9 10 1 Laser Specifications 9 10 2 General 10 10 3 Installation Environment 12 10 4 Compliance 12 11 0 OPTIONS AND ACCESSORIES BACK Monarch Instrument s Limited Warranty applies See...

Страница 4: ...Compatible pulse per revolution and has the ability to compute the RPM internally and output the ASCII values to any equipment capable of receiving an RS232 input For best performance use reflective...

Страница 5: ...nks RED when fast charging for very low batteries Blinks AMBER when slow charging Steady AMBER when the batteries are fully charged 5 Polarity switch Selects either a positive or negative output pulse...

Страница 6: ...her RPMs the LED will be on solid 3 5 If after completing step 3 4 the On Target LED 1 blinks erratically or not at all rotate the Sensitivity Adjust knob 7 slowly from 1 to 9 until the LED blinks reg...

Страница 7: ...put A variety of optional cables are available including tinned wire termination 1 8 inch 3 5 mm mono plug or DB9 for RS 232 Refer to Table 1 and Figure 3 for the output socket connection detail DC Po...

Страница 8: ...AC charger power supply To turn the unit off slide the Power switch 8 to the Off Charge position If the charger is plugged in the batteries will charge The sensor emits a laser beam which is reflected...

Страница 9: ...se and the Auto Gain LED 3 is on Aim the laser at your target Press and hold the Learn Gain button 6 until the On Target LED 1 blinks regularly or is on solid depending on the RPM of the target Releas...

Страница 10: ...black target When the unit is first turned on the On Target LED 1 will indicate which target type the sensor is set up for While the Laser On LED 2 is blinking the On Target LED will be on for a white...

Страница 11: ...enhanced at long distances by slipping a piece of black tube with a minimum inner diameter of 0 6 inches over the nose piece to act as an extension nose piece This tube should not deflect the beam in...

Страница 12: ...supplied PR Universal charger with the sensor 10 0 SPECIFICATIONS Note Product specifications are subject to change without notice 10 1 Laser Specifications Classification Class 3R per IEC 60825 1 Edi...

Страница 13: ...tors LEDs for On Target Laser On Auto Gain Power Charge Modes Normal manual or Auto and charging Normal mode manual adjustment of sensitivity gain Auto mode auto learn automatic gain control Sensitivi...

Страница 14: ...esistor to user supplied power max 24 V required Polarity Positive or Negative pulse switch selectable RS232 Transmit Out ASCII value of RPM Accuracy 0 002 of reading Settings 9600 baud 8 bits 1 stop...

Страница 15: ...32 to 104 F 0 to 40 C operating 14 to 158 F 10 to 70 C storage Humidity Maximum relative humidity of 80 for temperatures up to 88 F 31 C decreasing linearly to 50 relative humidity at 104 F 40 C 10 4...

Страница 16: ...h 13 mm wide T 5WP Waterproof Reflective Tape honeycomb pattern 5 foot 1 5 m roll 1 inch 25 mm wide SLS CA BNC Cable assembly with BNC connector SO SLS CA W Cable assembly with tinned leads SLS CA P C...

Отзывы: