The T-5 tape supplied with the ROS-HT-W-25 is rated at
175 °F [79.4 °C] for continuous exposure and 250 °F [121 °C]
for intermittent exposure (30 minutes).
The sensor should be mounted and optically aligned to illuminate
the target once per revolution. The user must hold “steady” or
mount the ROS-HT-W-25 to obtain an accurate measurement. It is
recommended that the optical Sensor be placed at a slight angle
(15 degrees) from perpendicular, so that the Sensor will receive
only pulses from the reflective marker. The ROS-HT-W-25 should
be at least 1 inch from the reflective target to avoid false triggering.
The ROS-HT-W-25 will work with all Monarch panel instruments
that accept pulse inputs (e.g. ACT Series, F2A Frequency to Analog
Converter/Tachometers, DataChart™ 1250, DataChart™ 6000).
CAUTION: DO NOT HANDLE SENSOR AT ELEVATED
TEMPERATURES.